Ingeniería Mecánica
Permanent URI for this collectionhttp://repositorio.uta.edu.ec/handle/123456789/900
Browse
6 results
Search Results
Item Diseño e instalación de un sistema fotovoltaico para una vivienda unifamiliar en la parroquia Viche, provincia Esmeraldas(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2024-08) Loor Naranjo, Steven Manuel; Mayorga Pardo, Alex SantiagoOn the "Mi Quinta" farm, located in the parish of Viche, province of Esmeraldas, the remoteness of the national electricity grid makes it unfeasible to install electricity. This situation is common in rural areas of the coast, where the high installation costs and the environmental impact of felling trees for the power lines generate an urgent need for alternative energy sources. The existing problems on the farm have led to consider the use of renewable energies as a viable solution to supply energy needs. This project focused on designing and installing a photovoltaic system for a single-family house on the farm. First, the energy needs of the house were assessed to ensure that the system would provide sufficient energy for the daily use of appliances and lighting. Then, the components of the PV system were carefully selected to ensure efficiency and durability, and installation proceeded, ensuring that all elements worked together optimally and that the solar panels were properly oriented to maximize solar energy collection. The results indicate that the PV system ensures a reliable and efficient energy supply for the "Mi Quinta" house. This project significantly addresses the rural energy problem, providing a long-term sustainable and cost-effective solution. Six-monthly monitoring and the use of MPPT charge controllers are recommended to optimize the efficiency and durability of the system, as well as the periodic revision of the battery bank to avoid total discharges, especially on consecutive cloudy days.Item Diagnóstico térmico para la instalación de un sistema para calentamiento de agua de uso sanitario unifamiliar utilizando energía solar térmica en la comunidad de río Blanco, provincia de Tungurahua(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2018) Hinojosa Herrera, Johnny Santiago; López López, Germánico AdánThe present project aims to perform the thermal diagnosis for the installation of a system for heating water for single family sanitary purposes using solar thermal energy in the community of Rio Blanco, Tungurahua Province. For the development of the project, a preliminary study of the solar irradiation of the Rio Blanco area will be carried out, in order to determine which is the most efficient water heating system that adapts to the climatic conditions of the aforementioned sector. Two systems were installed, one of vacuum tubes and one parabolic cylinder, the measure of the water inlet temperature to the collectors was taken to be 5 ° C, then the hourly temperature of the exit temperature was measured. twelve days in both systems. The results of the temperatures obtained with an average irradiation of 2.88 are 40.98 ° C with the vacuum tube system, and 21.08 ° C with the parabolic cylinder system. Achieving an average energy quantity of 8.74 kW-h with the vacuum tube system and 2.42 kW-h with the parabolic cylinder system. It is concluded that the solar vacuum tube heater is the most acceptable for the climatic conditions of the sector, since the temperature needed to take a nice bath is around 30 to 36 ° C, therefore, if we have daily hot water at 40 ° C, with this system would be fulfilling the needs of hot water of this population.Item Diseño y simulación de un sistema fotovoltaico para la obtención de una certificación leed en la categoría de energía y atmósfera para la empresa Solinfra de la ciudad de Quito(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2017-07) Robalino Peñaloza, Daniel Alejandro; Paucar Samaniego, Mayra AlejandraThe present technical project is based on the design and simulation of a Photovoltaic System to obtain a LEED certification in the Energy and Atmosphere category for the company SOLINFRA of the city of Quito. This system consists of 12 photovoltaic panels connected to each other, 8 in series and 4 in parallel, to meet the demand for basic lighting of the company which is 2374.75 W in the worst case, with a solar inclined solar radiation of 202, 78 W / m2 (March), taking advantage of the energy from the sun and converting it into electrical energy, thus optimizing economic resources and reducing energy consumption, generating a commitment to the environment and society. It includes a numerical simulation of the system, to obtain power graphs in the worst-case scenario and obtain the power curves at the output of the photovoltaic panel and inverter. An economic analysis determines the investment cost of the project at $ 18,251.91 dollars, with a three-month investment recovery in one month, considering that the energy generated by this project will be sold to the National Interconnected System of Ecuador, demonstrating the feasibility of the proposal.Item Estudio comparativo entre un panel fotovoltaico fijo y Móvil de 50w policristalino y su incidencia en la captación De energía solar en la ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2016) Sánchez Pérez, Leni Wilfrido; Mayorga Pardo, Alex SantiagoItem Estudio de aislantes térmicos para cubierta en paneles solares plásticos y su influencia sobre la eficiencia para el calentamiento de agua aprovechando la energía solar absorbida en la ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2014-02) Peña Valencia, Santiago Ramiro; Cabrera Anda, Santiago PaúlEl presente trabajo está orientado al estudio de aislantes térmicos en la cubierta de un panel solar de polipropileno realizando mediciones de: irradiación, temperatura a la entrada y salida de agua, temperatura ambiental, velocidad de viento, para ello se utilizaron fichas técnicas como ayuda para registrar los datos necesarios para la realización de la investigación. Realizamos un corte al panel dividiéndole en dos partes, cada una constituida de 78 tubos de calentamiento lo cual se hizo para tomar las medidas al mismo instante con y sin aislamiento. Tomamos la medida de entrada de agua al panel de 17 °C, luego se procedió a la medición cada 15 minutos de la irradiación, de la temperatura de salida de agua con y sin aislamiento, la velocidad de viento y la temperatura ambiental. Los resultados obtenidos en la medición son de 511,35 W/m2 de irradiación promedio con la cual se alcanzó una temperatura a la salida del agua del panel con aislamiento de 46 °C y 40°C sin aislamiento. Logrando obtener como calor útil 180,48 W utilizando el aislante térmico y 143,14 W de calor útil sin aislamiento. Llegando a obtener perdidas de calor desde el interior del tubo hacia el ambiente de 13,96 W sin aislamiento y 9,48 W con aislamiento. Lo cual alcanzamos una eficiencia de nuestro panel de 44% con aislamiento y 35% sin aislamiento logrando cumplir con nuestra hipótesis de aumentar la eficiencia en un 9% es decir llegando a alcanzar una mejor captación de la energía solar en la ciudad de Ambato en los meses de Junio y Julio del año 2013.Item Influencia del estudio de la tecnología de vacío en tubos sobre la eficiencia para el calentamiento de agua usando la energia solar(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2011) Salcedo Cobo, Victor Manuel; Cabrera Anda, Santiago PaúlEste proyecto fue enfocado al estudio de la eficiencia en los calentadores solares de tubos al vacío, para de esta manera comparar con la eficiencia de los calentadores tradicionales de serpentín o paralelos. Otra de las razones por lo que se investiga la influencia que tiene la utilización del vacío es de evaluar las temperaturas que puede alcanzar el agua almacenada. Otro motivo para la realización de este estudio fue el interés de investigar un nuevo sistema que permite tener un mayor aprovechamiento de la energía solar y evitar que la energía almacenada se pierda en cantidades considerables una vez que las condiciones climatológicas cambien repentinamente, es decir haya presencia de viento o lluvia. Con las conclusiones obtenidas de este estudio en el capítulo cinco se puede determinar que con el uso de la tecnología de vacío se logra calentar una cantidad de agua considerable y se alcanza una temperatura satisfactoria de aproximadamente 62 ° C, para alcanzar esta temperatura se necesita de un tiempo de seis horas y se logra almacenar una energía útil de aproximadamente 1854,61 W. Es por este motivo que se propone el diseño y construcción de un calentador solar de tubos al vacío para poder evaluar su eficiencia, la cual fue de aproximadamente del 81,8 %, con estos resultados obtenidos se puede comprobar que los calentadores con tecnología de vacío son superiores a los calentadores convencionales.