Ingeniería en Sistemas, Electrónica e Industrial
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/1
Examinar
4 resultados
Resultados de la búsqueda
Item type:Ítem, Condiciones térmicas adversas por calor en la empresa Megallantas S.A.S.(2025-07) ;Solís López María de los Ángeles ;Morales Perrazo Luis AlbertoUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera de Ingeniería IndustrialThe tire retreading process involves workers being constantly exposed to heat generated by the industrial equipment used in the process. Given this issue, the study aimed to assess the thermal conditions caused by heat among workers in the production department of the company MEGALLANTAS S.A.S., in order to determine whether these conditions exceeded the permitted risk levels. The research was conducted using a quantitative approach, based on which numerical data derived from direct measurements and technical calculations were collected and analyzed. Heat stress was assessed in accordance with the methodology established in the UNE-EN ISO 7243 standard, using a heat stress meter (SPER SCIENTIFIC) and an anemometer (AR856) to collect environmental variables. Likewise, the metabolic consumption of the workers was estimated by applying NTP 1189. Finally, thermal comfort was evaluated under the parameters of the UNE-EN ISO 7730 standard, calculating the PMV and PPD indices, which made it possible to determine whether the workstations were in conditions of thermal stress or discomfort. The results showed the presence of thermal stress in the tire assembly, enveloping and vulcanizing stations, as well as thermal discomfort in the initial inspection, scraping, reaming, repairs, filling and belt cutting stations, which are heat generating sources. The WBGT index values in the affected stations ranged between 20.23 and 23.60 °C, exceeding the established permissible limits. In addition, the analysis of the PMV and PPD indexes showed that more than 50% of a total of 7 workers presented significant levels of thermal dissatisfaction, with PPD values between 66.08% and 99.92%, reflecting thermal levels between “slightly hot” and “very hot”. It was proposed to reduce the main source of thermal stress through controls at the source, the environment and the person, prioritizing the most effective actions and reinforcing them with complementary measures.Item type:Ítem, Estrés térmico mediante la metodología del cálculo de la sobrecarga térmica estimada para la nave de pintura en el área Elpo de la Empresa CIAUTO(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera Ingeniería Industrial en Procesos de Automatización, 2019-03) ;Quinatoa Hidalgo, Jessica FernandaCabrera Acosta, Andrés GonzaloEn la nave de pintura de la empresa CIAUTO, se observa que los trabajadores del área ELPO sudan considerablemente a lo largo de la jornada laboral, debido a las condiciones de trabajo, en los procesos realizados dentro del área. El objetivo primordial de la presente investigación es evaluar estrés térmico mediante la metodología de la sobrecarga térmica para conocer si la empresa CIAUTO CIA LTDA. cumple con los parámetros que establece la ley y salvaguardar la integridad de los empleados que se encuentran inmiscuidos en el área ELPO. Para la evaluación del estrés térmico y la sobrecarga térmica se efectuaron tres mediciones de temperaturas de aire, globo, humedad relativa e índice WBGT en diferentes horarios a distintos niveles de altura en los puestos de trabajo que corresponden al área ELPO de la empresa CIAUTO, además se tomó lecturas de temperatura de la piel a los 10 operarios que desempeñan sus labores dentro de este espacio; las medidas se registraron en 4 días soleados del mes de septiembre en horas de la mañana, medio día y tarde con los equipos especializados para medidor estrés térmico como son anemómetro, cámara térmica; parámetros necesarios para la aplicación de la metodología de determinación analítica e interpretación del estrés térmico mediante el cálculo de la sobrecarga térmica estimada que propone la Norma UNE-EN ISO 7933:2005. Los resultados muestran un nivel de estrés térmico por debajo de los límites permisibles según dispone la ley, estos se encuentran en un rango de 16,5°C <= WBGT <= 22,72ºC con una tasa metabólica comprendida entre 90 XVIII W m 2 <= M <= 115 ; de los resultados de la sobrecarga térmica se obtiene que ningún trabajador supera el límite de 38°C de temperatura rectal final durante la jornada laboral estando está comprendida entre 37,14°C <= T re,i <= 37,68°C. Del estudio realizado se obtiene que los operarios sienten molestias al trabajar con temperaturas elevadas, sin embargo, estas no son perjudiciales para su salud debido a que el consumo metabólico empleado para las tareas es bajo ya que el proceso es automatizado en su mayoría. ABSTRACT In the paint shop of the company CIAUTO, it is observed that the workers of the ELPO area sweat considerably during the working day, due to the working conditions, in the processes carried out within the area. The main objective of this research is to assess thermal stress using the thermal overload methodology to know if the company CIAUTO CIA LTDA. It complies with the parameters established by law and safeguards the integrity of employees who are involved in the ELPO area. For the evaluation of thermal stress and thermal overload, three measurements of air temperature, balloon, relative humidity and WBGT index were made at different times at different height levels in the work stations corresponding to the ELPO area of the CIAUTO company. skin temperature readings were taken of the 10 workers who perform their work within this space; the measurements were recorded on 4 sunny days of the month of September in the morning, midday and afternoon with specialized equipment for thermal stress meter such as anemometer, thermal camera; necessary parameters for the application of the methodology of analytical determination and interpretation of thermal stress by calculating the estimated thermal overload proposed by the UNE-EN ISO 7933: 2005 standard. The results show a level of thermal stress below the permissible limits according to the law, these are in a range of 16,5°C <= WBGT <= 22,72ºC with a metabolic rate between entre 90 XVIII W m 2 <= M <= 115; of the results of the thermal overload, it is obtained that no worker exceeds the limit of 38ºC of final rectal temperature during the working day, being between 37,14°C <= T re,i <= 37,68°C. The study shows that operators feel discomfort when working with high temperatures, however, these are not harmful to their health because the metabolic consumption used for tasks is low since the process is mostly automated.Item type:Ítem, Estrés térmico y su incidencia en la fatiga normal de los trabajadores del área de producción de la Curtiduría Hidalgo(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Dirección de Posgrado. Maestría en Seguridad e Higiene Industrial y Ambiental, 2017) ;Jordán Hidalgo, Edisson PatricioCalisto Ramírez, María GraciaEXECUTIVE SUMMARY The purpose of the present work is the evaluation of thermal stress and determine its influence on the normal fatigue of the workers of the area of production of the Curtiduría Hidalgo of the city of Ambato; This company has shown a drop in production and the presence of uncomfortable temperatures and fatigue in workers. The evaluation procedure proposed by the American Conference of Governmental Industrial Hygienists (ACGIH) was used for the measurement, the measurement methods used were those proposed by UNE EN 27243 and UNE EN ISO 7730; All the workstations of the area of production were analyzed, being determined the indices of thermal insulation of the clothes of the workers; We performed the measurement of the WBGT index and for the calculation of the PMV and PPD indices was performed with the software DeltaLog10. To prove the presence of fatigue, the SOFI-SM and Yoshitake questionnaires were applied. The results obtained determine that there is no thermal stress, but if there is the presence of thermal discomfort in all areas of tannery production and the application of questionnaires determine the existence of fatigue in 41% of employees. The research proposal includes the design for the installation of fans in the production area of the company, selection of the fan and accessories, civil works for their placement and determination of the cost of placement. For fatigue is designed active pauses and methods of training and evaluation for forced positions and handling of loads that exist in this type of companies.Item type:Ítem, El estrés térmico y su incidencia en los trastornos sistémicos de los trabajadores del proceso de secado en la empresa Agroindustrial AGROCUEROS S.A.(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Dirección de Posgrado. Maestría en Seguridad e Higiene Industrial y Ambiental, 2016) ;Delgado Salazar, Carlos EduardoCórdova Suárez, Manolo AlexanderEXECUTIVE SUMMARY This research in the agro-industrial AGROCUEROS S.A is based on the set out of diagnosis reflected with quantitative risk identification, surveys made to directly and indirectly implicated, techniques and instruments that facilitate data collection, the same as after analysis and processing of information indicate that there is a high incidence of systemic disorders related to high temperatures, also through WBGT qualifier measurements and calculation of metabolic heat load produces it obtained as a result an overdose of exposure to heat in the drying process due to various factors such as: position and motion of the body, type of labor, rate of task, basal metabolism, exposition time and so on, additionally caloric spending and average temperature generated in the environment the same that have been compared to international standards, based on standards ISO 8996: 2004 and ISO 27243: 1993, to conclude it has been proposed several technical and administrative recommendations focused on improving risk management company, obeying national legislation (D.C. 513 -Regulation of General Insurance Labor Risks), by methods of control at the source, means and receiver, as well as the development of a prevention program for heat exposure ,the same procedures consisting of seven inherent heat produced in the drying process: training, correct use of EPP (PERSONAL PROTECTION EQUIPMENT), hydration, health monitoring, immediate response in the face of heat emergency , Clo establishment of (thermal insulation work clothes), HEATSOFT 1.0, management software. This program is oriented to prevent and guide to all workers and administrative staff who are involved in the identified areas that generate high temperatures, as a result of the production process, in order to minimize injuries, accidents (mishaps) and occupational diseases in the operating company workforce.
