Ingeniería en Sistemas, Electrónica e Industrial
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/1
Examinar
2 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis de los niveles de iluminación en la empresa Megallantas S.A.S(2026-01) ;Yancha Calapiña Gladys Isabel ;López Arboleda Jéssica PaolaUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera de Ingeniería IndustrialThe purpose of this study was to evaluate the lighting conditions in the operational and administrative areas of MEGALLANTAS S.A.S., to identify deficiencies, determine the level of regulatory compliance, and propose improvement measures to optimize visual safety, efficiency, and work quality. To this end, systematic illuminance measurements were taken on three different days, considering the variability of natural light and the stability of artificial lighting fixtures. The results revealed significant fluctuations among the evaluated workstations: some areas presented levels below the recommended values, especially in critical production processes, while other spaces showed over-illumination or low uniformity. The analysis of uncertainty, measurement errors, and repeatability showed that the variations were mainly due to environmental conditions, which reinforced the need for technical intervention. Based on these findings, an improvement plan was developed that includes the redistribution of light fixtures, implementation of high-efficiency LED systems, control of natural light entry, installation of task lighting for visually demanding tasks, and the establishment of a preventive maintenance program. These actions aim to correct deficiencies, standardize lighting levels, and ensure safer and more efficient operation. In conclusion, the study provides the technical and methodological basis for decision-making aimed at the continuous improvement of the lighting system at MEGALLANTAS S.A.S., contributing to the well-being of workers and strengthening the production process.Item type:Ítem, Estudio lumínico en la Cooperativa de Ahorro y Crédito Oscus Ltda.(2025-07) ;Chasi Moya Gabriela Monserrath ;López Arboleda Jéssica PaolaUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera de Ingeniería IndustrialThe objective of this research project was to conduct a lighting study in the corporate building of the Cooperativa de Ahorro y Crédito OSCUS Ltda., because there is no recent record of lighting studies and due to the old infrastructure of the building it was necessary to know the lighting levels to which the employees are exposed. The research modality used follows a qualitative-quantitative approach, since qualitative aspects were considered when determining the current lighting conditions under the parameters mentioned by the Mexican Official Standard NOM-025-STPS-2008, through the application of an area/workstation inspection form in which it was determined that there are 114 work areas subject to study, In the description of the area it was found that both walls and ceilings use light and bright colors, in the general lighting conditions, the most commonly used lighting fixtures in the building are LED tubes and LED sheets, in addition, the type of lighting in 52 areas use only artificial lighting and 62 areas use mixed lighting. It follows a quantitative approach, since measurements of lighting levels were taken with the help of an EXTECH INSTRUMENTS HD-450 luxmeter and as a reference the lighting levels recommended by the Spanish Standard UNE-EN 12464-1:2022, the measurements were compared with the standards and it was determined that 32 work areas do not comply with the minimum levels, in the uniformity factor 47 work areas do not have a good distribution of lighting fixtures and with respect to the reflection factor all work stations are within the permitted level, in contrast to surfaces such as walls that have highly reflective characteristics directly affecting the lighting comfort of employees.
