Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 7 de 7
  • Item type:Ítem,
    Análisis de desempeño sísmico del edificio COAC San Martín ubicado en el cantón Tisaleo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil., 2025-02)
    Yugcha Rumiguano, Christian Sebastián
    ;
    Peñafiel Valla, Lourdes Gabriela
    Ecuador is located in the Ring of Fire, so it is subject to stochastic phenomena such as earthquakes, since buildings must be governed according to the current NEC 15 standard to ensure that the design meets earthquake resistance criteria. The purpose of this research work is to determine the seismic performance of the building under study. A qualitative analysis was carried out using the NEC 15 standard, in which the parameters were evaluated according to the characteristics of the structure, obtaining a score of 2.0, demonstrating that it has a medium degree of vulnerability. In the quantitative section, the linear and nonlinear static Pushover analysis of the structure was carried out using engineering software. In the linear analysis, it was determined that the structure in current conditions presents torsion, and that elements such as beams and columns are not designed to withstand the demands. In addition, through non-linear analysis, the capacity curve of the structure was calculated together with the performance levels and it was determined that the construction does not meet the seismic performance objectives according to VISION 2000. Once the evaluation of the structure was completed, three more floors were designed, according to the specifications of the calculation report, and with the requests of these, the structure was reinforced, both locally in the elements such as columns and beams using criteria from the ASCE 41-13 standard, in which the concrete screed method was used for the columns and the steel casing method for the beams, and globally with the implementation of shear walls to control torsion and comply with the vibration period of the structure. Finally, with the implementation of the reinforcement and the addition of 3 more floors to the building, the linear analysis was carried out again, to verify that the calculations and design were in accordance with the NEC 15 standard, checking that the elements had the necessary amounts of steel to generate ductility. After that, the non-linear analysis of the structure was carried out, in which the performance objective was determined, complying with what was established in VISION 2000.
  • Item type:Ítem,
    Análisis del comportamiento a flexión de vigas de hormigón reforzado con fibras de polipropileno / polietileno”
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2023-01)
    Mera Ortiz, Roger Ricardo
    ;
    Ramírez Cabrera, Wladimir José
    The addition of fibers in concrete represents a new technique aimed at improving the tensile behavior developed by simple concrete, although its use is relatively new, more and more research seeks to characterize how fibers influence the concrete properties. The present degree work studied the influence of polypropylene/polyethylene fibers (Tuf Strand SF) in concrete. The characterization of the properties of the aggregates are necessary to get the dosage of the concrete, using a resistance of 240 kg/cm2 to compression. Dosages of 3 and 6 kg/m3 of fiber and simple concrete were used to get a comparative analysis, making a total of 27 50x15x15cm beams according to the recommendations of ASTM 1609 standard. Once the results were obtained, the Load vs. Deflection graphs were prepared to compare deflections, residual strengths and fracture energy between the different volumetric fractions. The study of fiber distribution was carried out by counting fibers, in specified areas, of the semi-sections of the specimens, obtaining the orientation coefficient by areas and total. The comparison of the performance of simple and fiber-reinforced concrete allowed us to verify that the addition of fibers in the concrete improves its ductility and the fiber count corroborated the influence of the "Wall Effect" on the distribution of fibers in the concrete matrix.
  • Item type:Ítem,
    Análisis técnico económico del coeficiente de reducción de respuesta estructural con aplicación y comparación en sistemas aporticados de estructuras metálicas
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Jácome Guanopatín, Ángel Patricio
    ;
    Cañizares Ortega, Freddy Fernando
    In this degree work, the analysis and calculation of the seismic reduction factor for a structure with special moment frames (PEM or SMF) composed of four different mathematical models where the seismic reduction factor changes with values of R=8, 6, 4, 5 and 3. 5 and 3; performing the dynamic linear structural analysis of the four models, each structure changes according to the demand required by the seismic forces, determining that the lower the value of R the larger sections are required in the structure, in spite of the above, the fundamental vibration period of the structures was maintained for R= 8, 6 and 4. 5, while for the factor R=3 the period is slightly reduced resulting in a stiffer structure, as the seismic response factor is reduced, more robust sections are required to provide more weight to the structure to meet the demand. An economic analysis was performed with the sections obtained, which shows that the lower the R value, the structure requires a higher weight and therefore influences a higher cost, so the structure with the lowest cost is the structure with an R=8. Additionally, a pseudo-static non-linear analysis was determined to determine the structural performance of each of the four models using the ATC-40 and FEMA- 440 methods, highlighting that the models maintain the same architectural and geometric configuration but with different sections in certain elements that required a higher geometry as the R value decreases, after obtaining the results of the static non-linear analysis, the performance point was determined using the ASCE 41-17 and FEMA 440 (2005) methodology, resulting in the R=8, 6, 4. 5 and 3 for 475 years has a performance level in X and Y of immediate occupancy. For the determination of the structural response factor, the methodology proposed by Dr. Aguiar 2006 was followed, which is similar to that of ATC-19 (1995), where the ductility, resistance and redundancy factor is determined, data that are collected from the performance point obtained for the elastic design spectrum with a return period of 475 years, the structural response factors R obtained establish that the average range is between 6 and 7.5, on the other hand the structure that presents greater capacity and performance is the one that was designed with R=4. 5 so having extremely rigid sections does not guarantee stability and ductility in a structure, finally a high level of performance (immediate occupation) and seismic energy dissipation capacity is established in the structure designed with a R=6 where its value is similar and slightly lower than 4.5, so it is concluded that for a structure of special steel composite moment frames a design with a structural response factor equal to 6 should be sought.
  • Item type:Ítem,
    Vulnerabilidad sísmica del parqueadero municipal del Gobierno Autónomo Descentralizado de Ambato, ubicado en la calle Cuenca y Montalvo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Lucio Álvarez, Diego Ricardo
    ;
    Peñafiel Valla, Lourdes Gabriela
    Ecuador is located in the ring of fire, so different earthquakes at various levels are very common, the structures must be designed to withstand an earthquake of a rare level, the constructions must be ductile; the ductility is the time that the occupants of the structures have to be able to go out to a safe place, the secondary waves of the earthquakes are the ones that knock down the buildings, through the present study a building located in the central area of Ambato was taken as a sample , this structure should be in a life safety acceptance criteria, to start the present study the forms established by FEMA 154 and NEC 2015 were used and a visual inspection of the structure was carried out to know the irregularities in plan and elevation, In addition to knowing pathologies that the structure has, the main pathology is the short column, the parameters of the forms were established and it was concluded that it has a medium seismic vulnerability, with this information a nonlinear static analysis was carried out, it was necessary to use a computer program such as Etabs19, where the steel area was placed in each of the beams and columns, with this information formation we obtainedxxiv the plastic hinges, as well as the performance point and the capacity of the building under study, in which it was observed that the structure does not meet this acceptance criterion for the design earthquake, which is why it is necessary to carry out a reinforcement in beams, but above all in C2 columns, which are the columns that act the most in these two buildings. There are several methodologies for reinforcing structures among the most common (reinforcement with carbon fiber, reinforcement with screeding of structural elements and reinforcement with steel), reinforcement with angles and plates of A36 steel was chosen, these angles fastened with plates and bolts they help to gain ductility and more shear strength of the structure in order to meet the acceptance criteria for this type of building, which is life safety.
  • Item type:Ítem,
    Efectos de la adición de aceite usado de motor en las propiedades mecánicas de mezclas asfálticas en caliente
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-07)
    Martínez Herrera, Carlos Jefferson
    ;
    Núñez Aldás, Galo Wilfrido
    In the present work, hot asphalt mixtures were prepared using the Marshall method with the addition of used motor oil in the Alvarado Quarry. First, the aggregates were sampled and transported, then the physical and mechanical properties were tested, and then the asphalt cement was sampled. Forty-five test specimens (briquettes) were made, with oil contents from 0 to 2 percent, making fifteen specimens for each consecutive percentage. The used motor oil was added to the asphalt mix as a fraction of the asphalt cement by weight, following the procedure established in ASTM D 1559, AASHTO T 245 and AASHTO T 225. Once the briquettes were made, they were tested to obtain the percentages of stability and flow, where it was determined that the optimum percentage of asphalt in the conventional mix is 6.07 percent and complies with the requirements of the Nevi-12 Standard, while the optimum percentage of the mixes modified with used motor oil at 1 and 2 percent were 6.35 and 6.42 percent, the mixes satisfy stability parameters, however, the flow values are high, and an increase in the void content was also evidenced as the used motor oil content increased.
  • Item type:Ítem,
    Análisis de las combinaciones porcentuales del material de aporte de una junta a tope en un acero ASTM A588 Grado A utilizando los alambres tubulares E71T1 y E81T1NI2 para determinar las propiedades mecánicas en la fabricación de superestructura para puentes
    (2016)
    Analuiza Maiza, Oscar Iván
    ;
    Paredes Salinas, Juan Gilberto
    For the present research work, three types of percentage combinations of tubular wires were made in a butt joint steel ASTM A 588 Grade A. Afterwards, the test specimens were obtained to perform destructive test of traction, impact, double guidance and macrography in order to determine the mechanical properties. The analysis and interpretation of results helped to determine, the best combination of the filler material. Finally, a proposal of a WPS and PQR welding process is set up to combine 80% E71T1 - 20% E81T1NI2 along with CO2 as protection gas which has proved to be the combination with the best mechanical properties. This research project is based on the AWS D1.5 code, which contains the general provisions, design of connections, execution, techniques and qualification for the welding of bridges. The development of this project counted on the equipment of the laboratories and advice from civil engineering and mechanics faculty teachers of the Technical University of Ambato.
  • Item type:Ítem,
    Análisis de recocido en soldadura de acero AISI 1018 con electrodo AWS E-7018 y su incidencia en las propiedades mecánicas
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Diseño Mecánico, 2012)
    Vaca Ortega, Wilson Henry
    ;
    Valle Velasco, Pablo Raúl
    El presente trabajo muestra la investigación realizada en juntas de Acero AISI 1018 soldadas con electrodo AWS E-7018, las que fueron sometidas a tratamiento térmico de recocido, con la finalidad de comparar las propiedades mecánicas de una junta sin tratamiento térmico posterior a la soldadura y las analizadas a tres temperaturas diferentes 600ºC, 780ºC, 870ºC, y a dos tiempos distintos una y tres horas. Se realizaron ensayos de tracción, dureza, impacto y análisis metalográfico en los laboratorios de la Facultad de Ingeniería Civil y Mecánica de la Universidad Técnica de Ambato para determinar la variación de las propiedades mecánicas con las seis condiciones de recocido, posteriormente los registros fueron tabulados y analizados. Se obtuvo conclusiones y recomendaciones en función de los resultados obtenidos, que contribuyen a generar procesos de recocido posterior a la soldadura que pueden ser aplicados en el campo industrial. Finalmente se determinó el proceso que mejor combinación de propiedades mecánicas produjo, y se desarrollaron los procedimientos respectivos.