Maestría en Ingeniería Civil con Mención en Estructuras Metálicas

Permanent URI for this collectionhttp://repositorio.uta.edu.ec/handle/123456789/34193

Browse

Search Results

Now showing 1 - 3 of 3
  • Item
    Estudio comparativo entre las juntas de conexión empernadas y por soldadura en el área de acceso vehicular y entre piso de la edificación del parqueadero ubicado en la av. 12 de Noviembre de la ciudad de Ambato y su incidencia en el comportamiento mecánico operacional
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09) Zavala Córdova, Luis Eduardo; Ureña Aguirre, Maritza Elizabeth
    This degree work is based on a building that was built in the city of Ambato in order to determine what would be the optimum behavior to the requirements established by the structural design standards, for which we proceeded to perform a quantitative analysis in the collection and analysis of results in the comparison of the joints that are currently built by welding, to perform the analysis by connections of RBS and BFP joints, taking into account the criteria of the Ecuadorian Construction Standard (NEC-15), Load and Resistance Factor Design (LRFD) and American Institute of Steel Construction (AISC 360-16), this analysis contributes to the modeling of bolted and welded connections, in order to analyze the localized buckling phenomenon in the wings and web of the metal profiles of the beam-column joint in the vehicular access area and the joint between floors, The results obtained showed that the RBS connection has a better deformation behavior without affecting the web and flanges of the profile, and that the BFP connection cannot be used in the same way as the BFP connection, the BFP connection cannot be used in joints where the inclination of the beam towards the column has a steep slope because the plates must be connected perpendicularly and the welding connection tends to be the most economical and can be used in any area, however it tends to reach the equivalent stressstrain deformation limit, in relation to the cost of materials used for the installation of the BFP joint it is more expensive because it implies placing more supply of elements in the joint.
  • Item
    Análisis comparativo de conexiones precalificadas con tipología soldadas y empernadas para un sistema SMF en un edificio de estructura metálica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09) Merino Mora, Verónica Jackeline; Chávez Rubio, Luis Enrique
    Ecuador is located in areas where constant and significant earthquakes occur, currently it has been possible to denote the vulnerability of structural steel buildings to a severe earthquake. The scope of this work was to carry out a comparative analysis of prequalified connections with welded and bolted typology for an SMF system in a metal structure building. The ANSI/AISC 360-16 standard is the standard that establishes the specifications for designing steel structures, the ANSI/AISC 341-16 standard indicates the seismic provisions for structural steel buildings and the ANSI/AISC 358-16, which analyzes the prequalified connections for use in special moments and intermediate frames, the standards present a guide for the design of prequalified metallic connections that were used as an instrument for the different mathematical calculations, in addition, applying this methodology, a model of a steel structure was made . National and international standards were used for the study and the Etabs 2019 and Ram Connection software, both with student licenses, were used for the structural analysis. This research performs the comparative analysis of RBS, BFP, BUEEP and WUF-W prequalified connections, with welded and bolted typology for an SMF system in a metal structure building. A structural and economic analysis of the metal frame building is obtained, concluding that the elements that make up the connection in a metal frame building have an elastic behavior. In addition, it was observed that the RBS connection provides the best reliability so that the transfer in the beams (plastic hinge) prevails before that in the columns, as an energy dissipation mechanism and complying with the design philosophy. Regarding the analysis of the cost of steel in beams and columns, it was known that steel in welded beams and columns is cheaper than steel in bolted beams and columns, due to the materials, equipment, machinery and labor used. in the construction process of metal structures.
  • Item
    Estudio de conexiones precalificadas y su incidencia en el diseño sismo resistente de edificaciones irregulares
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-03) Sánchez Guevara, Nelson Hernan; Guerra Avendaño, Oswaldo Marcelo
    Ecuador es un país de alta actividad sísmica. En el año 2016 se vio afectado por un evento sísmico el cual fue generado a raíz de un fenómeno producido entre la subducción de la placa de Nazca y la placa Sudamericana, lo cual dejó cuantiosas pérdidas económicas, humanas y de edificaciones, siendo esto un factor principal de suma importancia para la investigación en el campo de la ingeniería estructural. En el presente trabajo de investigación se realizó un análisis sismorresistente de tres edificaciones irregulares de baja, mediana y gran altura, conformadas por un sistema resistente a carga lateral de pórticos especiales resistentes a momento SMF de acero estructural, compuestos por columnas de tipo HEB y vigas IPE. Para empezar el proyecto se realizó un análisis de la configuración estructural de las edificaciones planteadas para luego aplicar las consideraciones que establece la norma ecuatoriana de la construcción para tomar en cuenta los casos correspondientes de irregularidad en las edificaciones tanto en elevación como en planta. Luego se procedió a resolver las estructuras mediante un análisis estático y dinámico lineal, logrando obtener resultados que muestran un adecuado comportamiento estructural y cumplan con los chequeos obligatorios normativos, como son el chequeo de las derivas de piso, la verificación del criterio columna fuerte – viga débil y el diseño de sus elementos estructurales. Las conexiones de acero son de gran importancia para garantizar el comportamiento sismorresistente de las edificaciones. En zonas de alta sismicidad es necesario utilizar sistemas de pórticos especiales resistentes a momento y que sus conexiones sean precalificadas, lo que garantizará la formación adecuada de las rotulas plásticas contribuyendo a obtener como resultado un apropiado comportamiento en el rango no lineal. Una vez finalizado los diseños estructurales de las edificaciones planteadas, se procedió a diseñar dos conexiones precalificadas como son la Conexión de Placa de Ala Empernada (Bolted Flange Plate BFP) y la Conexión de sección de viga reducida (Reduced Beam Section RBS) descritas en la norma AISC 358-16. Las conexiones se diseñaron de forma manual cumpliendo todos los parámetros establecidos en la normativa AISC 358-16 para finalmente realizar su respectiva validación y comparación de resultados obtenidos mediante el uso de un software especializado en el diseño de conexiones de acero obteniendo resultados similares.