Abstract. Postural evaluations are becoming a priority in a world where occu‐
pational diseases derivatives from ergonomic situations are progressively
common with serious consequences. This document proposes a semi-automatic
ergonomic evaluation system with Kinect V2, which use the RULA method. It
makes possible the discovery of conditions with postural risk and reduces errors
in the estimating the evaluators’ measurements due to lack of experience, exper‐
tise and handling of measurement instruments. Reducing the ergonomic evalua‐
tion time, compared to the direct postural evaluation method at a low cost. In a
controlled environment, 30 participants with homogeneous characteristics are
evaluated their postural work, using a direct method (goniometer) and a noninvasive
(Kinect
V2) method,
to
then
compared
the
statistically
results
using
the
coefficient
of correlation
named
Cohen’s
Kappa
and
vagueness
type
A.
The
final
RULA
scores
issued
by
the
direct
method
of
postural
evaluation
and
the
proposed
system
are
correlated.
The
uncertainty
results
established
in
the
angular
meas‐
urements
on
the
arm,
forearm,
wrist, trunk
and
neck
were
respectively
(±0.36°,
±0.22°,
±0.59°,
±0.27°
and
±0.28°).
A Cohen’s
Kappa
correlation
coefficient
of
0.953
was
obtained,
which
means
an
almost
perfect
correlation
between
the
eval‐
uations
of
both
systems.