Fiabilidad y validez de las evaluaciones posturales del sistema de evaluación ergonómico con el sensor Kinect V2

dc.contributor.advisorMariño Rivera, Christian José
dc.contributor.authorSantana Padilla, Rafael Iván
dc.date.accessioned2019-04-15T19:03:25Z
dc.date.available2019-04-15T19:03:25Z
dc.date.issued2019-03
dc.descriptionSublínea de investigación: Sistema de gestión de la salud, seguridad ocupacional y medio ambientees_ES
dc.description.abstractAbstract. Postural evaluations are becoming a priority in a world where occu‐ pational diseases derivatives from ergonomic situations are progressively common with serious consequences. This document proposes a semi-automatic ergonomic evaluation system with Kinect V2, which use the RULA method. It makes possible the discovery of conditions with postural risk and reduces errors in the estimating the evaluators’ measurements due to lack of experience, exper‐ tise and handling of measurement instruments. Reducing the ergonomic evalua‐ tion time, compared to the direct postural evaluation method at a low cost. In a controlled environment, 30 participants with homogeneous characteristics are evaluated their postural work, using a direct method (goniometer) and a noninvasive (Kinect V2) method, to then compared the statistically results using the coefficient of correlation named Cohen’s Kappa and vagueness type A. The final RULA scores issued by the direct method of postural evaluation and the proposed system are correlated. The uncertainty results established in the angular meas‐ urements on the arm, forearm, wrist, trunk and neck were respectively (±0.36°, ±0.22°, ±0.59°, ±0.27° and ±0.28°). A Cohen’s Kappa correlation coefficient of 0.953 was obtained, which means an almost perfect correlation between the eval‐ uations of both systems.es_ES
dc.identifier.othert1557id
dc.identifier.urihttp://repositorio.uta.edu.ec/handle/123456789/29574
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera Ingeniería Industrial en Procesos de Automatizaciónes_ES
dc.rightsopenAccesses_ES
dc.subjectERGONOMIC EVALUATIONes_ES
dc.subjectKINECT V2es_ES
dc.subjectNON-INVASIVE UNCERTAINTYes_ES
dc.subjectERGONOMÍAes_ES
dc.titleFiabilidad y validez de las evaluaciones posturales del sistema de evaluación ergonómico con el sensor Kinect V2es_ES
dc.typebachelorThesises_ES

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Tesis_t1557id.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: