Unidad de Posgrado Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/901
Examinar
3 resultados
Resultados de la búsqueda
Item type:Ítem, Diseño y análisis del parqueadero central de la ciudad de Ambato de hormigón armado y estructura metálica con el uso de elastómeros en la cimentación(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022) ;Sánchez Tenesaca, Estefanía Jacqueline ;Fiallos Condo, Jéssica TatianaChérrez Gavilanes, Diego SebastiánIn the present research work several factors are taken to determine the seismic safety of buildings, materials such as elastomers have been used for structural protection. The design and analysis of the central parking lot of the city of Ambato of reinforced concrete and metal structure with the use of elastomeric insulators in the foundation helps to improve seismic behavior. A modeling was carried out using software analyzing each of the structural elements, especially the behavior of the foundation. Structural and economic analysis shows that a structure equipped with elastomeric insulators in the foundation reduces its initial investment in the structural system since these are responsible for dissipating much of the energy that enters the system so the sections of the structural elements are reduced which implies savings. Its benefit is given in the long term reflected in the performance that the structure can achieve. In the analysis torsional distortion was visualized, we did not find the use of prequalified connections, factor of importance of the structure equal to one, vibration modes insufficient for a minimum mass participation of 90 percent, so we performed a verification through a linear analysis and a static nonlinear analysis with a factor of importance I = 1.5, , additionally, we must analyze the essential structures by means of a non-linear analysis for a return period of 2500 years as stipulated in the NEC SE DS 15. Therefore, this research determines the level of structural performance, as stipulated in the Ecuadorian Construction Standard in force, in the chapter of seismic design thus deducing that it was necessary to implement a structural reinforcement system, which at least allows the structure to remain at a level of (Life Safety) LS which is what the standard requires us.Item type:Ítem, Estudio de pórticos arriostrados concéntricamente en V, V invertida y arriostramiento en K y su incidencia en el diseño de un edificio en acero de 7 pisos(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-03) ;Salinas Villegas, Edisson XavierEspín Lagos, Segundo ManuelIn this research paper, a comparison was made between three types of bracing: in V, in Inverted V and in K of a 7-story building with the possibility of applying it in our environment as it is in the city of Ambato and also so that can be used at the national level since both national and American regulations were used. The pre-designs of the structural elements were made, both for the columns, main and secondary beams, collaborating plate, and the bracing elements to then carry out their respective design, first checking their compactness and slenderness in each of their elements. Through the use of finite element software, each of the structural elements was modeled, entering properties and specifications to its elements, a static and dynamic analysis was carried out, for which the load combinations were defined, and also the load spectrum. design, as well as the configurations of the structure in plan and elevation, in addition to the seismic zone according to the project that is being investigated, all this so that the 7-story structure is earthquake resistant and each of the checks stipulated by the Ecuadorian Construction Standard (NEC 2015). Comparisons were also made with the three different types of bracing and the price of the structure was analyzed. Finally, it was concluded that the best type of structure was the inverted V bracing, because it has a lower drift than the previous two with values less than two percent and has a good structural behavior compared to the other checks carried out as in the dynamic analysis that complies with a percentage greater than 80 percent, the rotational analysis less than 30 percent in both X and Y; and the participation of the mass greater than 90 percent.Item type:Ítem, Caracterización de elementos estructurales de acero que hayan sido expuestos a diferentes tiempos y temperaturas debido a un incendio(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-03) ;Guamanquispe Vaca, Fernanda PatriciaEspín Lagos, Segundo ManuelIn the present investigative work, different structural elements such as columns, beams and steel straps ASTM A 36 exposed to flagella were characterized, considering different times and temperatures of exposure; For the experimental part, the conditions were simulated by using a conventional furnace in which several samples of steel and combustible material were placed, trying to simulate a real scourge, after which samples were taken at temperatures of 600, 800 and 1000 degrees celsius and exposure times of 30, 45 and 60 minutes, to which hardness and macroscopy tests were carried out in the materials laboratory of the Faculty of Civil and Mechanical Engineering and to be able to determine the mechanical properties of the material subjected under these conditions and compare them with those of the unexposed material; By means of the hardness it was possible to determine the ultimate resistance of the material and from the percentages of Ferrite and Perlite it was also verified that the ultimate resistance toxvi traction increased by 9-10 percentage since the samples were cooled by means of a cold water jet, a condition that occurs when a fire is extinguished; Although it is true that the mechanical properties of the specimens did not vary significantly, from the bibliographic review it was possible to determine that in real time of the flagellum, the resistance to creep decreases in inverse proportion with the temperature, so it is possible that the structure collapses. At that time, from the aforementioned, it can also be said that if the structure does not collapse during the fire and is still standing and without deformations in the structure, it can continue to provide service; Finally, after the analysis, it was possible to conclude that the mechanical properties of the structural steel elements at the time of the fire depend on the time and temperature of its exposure.
