Ingeniería en Sistemas, Electrónica e Industrial
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/1
Examinar
3 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis del ruido natural y antropogénico del Parque Nacional Yasuní usando técnicas avanzadas de machine learning(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Maestría en Física Aplicada, 2022) ;Velasco Castelo, Geoconda MariselaVásconez Vega, Christian LeonardoThis paper addresses aspects of industrial noise produced by oil extraction facilities in the Yasun´ı National Park, located in the Ecuadorian Amazon. The acoustic sources within this type of installation influence the behaviour of wildlife, which has a negative impact on the species. The radial propagation model of acoustic wave propagation in an open field is posed through atenuation by geometric divergence, atmospheric absorption effect and scattering effects due to and ground scattering effects. The initial model without obstacles performs predictions based on an algorithm by taking an input data set and obtaining output data by developing a Machine Learning technique such as linear interpolation. And by means of an expansion of the model allows the influence of obstacles to be appreciated. The field measurements made by the research team give us information on atmospheric pressure provide us with information on atmospheric pressure, temperature, relative humidity and average sound frequency, at different distances from the sources. These data have allowed us to use the ISO 9613-1 Standard for the calculation of the absorption coefficient due to the effect of atmospheric absorption, as well as, the Nord2000 model to take into account the local flora that introduces reflection and scattering phenomena. In addition, the ground effect will include the presence of low vegetation. The results obtained will have a scientific, environmental and scientific, environmental and social impact, due to the effects of noise caused by the oil industry. Then, the results could serve as a basis for decision making in the field of environmental regulation, as well as social, with reference to indigenous communities living near oil installations.Item type:Ítem, Evaluación de la contaminación acústica en el proceso de producción de plásticos de la empresa Halley Corporación(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera Ingeniería Industrial en Procesos de Automatización, 2018-10) ;Valencia Flores, Franklin StalinTigre Ortega, Franklin GeovannyEl presente trabajo de investigación tiene como objetivo evaluar la contaminación acústica en el proceso de producción de plásticos de la empresa Halley Corporación. La contaminación acústica es una de las principales molestias o perturbaciones en el ambiente de trabajo y en el peor de lo casos es causante de enfermedades profesionales como la hipoacusia acústica. La investigación inicia con un reconocimiento del lugar de trabajo para tener conocimiento de las áreas que se va a realizar el estudio pertinente, la elaboración del Layout del área de producción, la estimación de las condiciones actuales de la empresa, la identificación de las fuentes de peligro generadoras de ruido mediante la aplicación del anexo A de la NTE INEN – ISO 9612 - 2014, la planificación del procedimiento para la medición de niveles de ruido, la medición de niveles de ruido de fondo con el sonómetro PCE-MSM3 y la medición de niveles de ruido laboral con el dosímetro EXTECH 407355 mediante la estrategia de medición basada en la función según la NTE INEN – ISO 9612 - 2014, el cálculo del nivel de ruido en el proceso de producción mediante la estrategia de medición basada en la función según la NTE INEN – ISO 9612 - 2014, el análisis de resultados cuyos resultados se comparan con los límites permisibles establecidos en normativas vigentes como es el Decreto Ejecutivo 2393 y proponiendo un plan de control y prevención de riesgos por la contaminación acústica en el proceso de producción de plásticos. Los resultados obtenidos muestran que el 11% de áreas de trabajo del proceso de producción de la empresa Halley Corporación se exponen a un nivel de ruido superior al límite permisible de 85 dB(A), el 33% de áreas de trabajo de la empresa se exponen a un nivel de ruido que se encuentra entre los 80 y 85 dB(A) y el 56% de áreas de trabajo se exponen a un nivel de ruido menor a 80 dB(A). Mientras tanto el 12% de áreas de trabajo del proceso de producción de la empresa Halley Corporación se exponen a una Dosis de Ruido Diario mayor al 100%, mientras que el 88% de áreas de trabajo de la empresa se exponen a una Dosis de Ruido Diario menor o igual al 100%. Por lo tanto se sugiere un plan de control y prevención de la contaminación acústica, necesario para mejorar las condiciones del ambiente de trabajo. ABSTRACT This investigation task has the objective to evaluate the acustic contamination in the process of plastic production in Halley Corporation. The acoustic contamination is one of the main problems in the working environment. Even, in the worst case it is one main reason to cause occupational illnesses like the acoustic hipocrisy. The process of investigation begins first identifying the place of working in order to know the areas available to work in and contains other process like the elaboration of Layout of the production area, the current conditions of the Company, the identification of the sorces of noise danger into the population according to Appendix A of NTE INEN – ISO 9612.The planning of the procedure to measure the levels of background noise with the sound meter PCE – MSM3.Also, the measure of the working noise with the sound meter EXTENCH 407355 through a strategy of measure according to NTE INEN – ISO 9612.The calculation of the noise level in the process of production based on the function NTE INEN – ISO 9612. The analysis of results, which are compared to the limited and allowed sounds in the current regulations such as the Executive order 2393 proposing a controlled plan and acoustic contamination risk preventions in the process of plastic production. The got results show that the 11% of the working areas of the production process of Halley Corporation are exposed to a high level of noise, which is superior to the permitted limit of 85 dB(A). The 33% of working areas of the company are exposed to a noise level that is between 80 and 85 dB(A) and the 56% of working areas are exposed to a noise level less than the 80 dB(A). While the 12% of the working areas are exposed to a dairy noise dose higher than the 100% and the 88% of working areas of the company are exposed to a dairy nose dose lower or equal to the 100%. As a result, it is recommendable to have a control plan and prevention of acoustic contamination, all of this is necessary to improve the conditions in the working environment.Item type:Ítem, Ruido Industrial y su repercusión en las otopatías ocupacionales del personal del Área de Producción, en Empresas Productoras de Botas PVC de la Ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Dirección de Posgrado. Maestría en Seguridad e Higiene Industrial y Ambiental, 2017) ;Sánchez Barreno, Víctor HugoEspín Guerrero, Víctor RodrigoEXECUTIVE SUMMARY Given that noise is one of the most common factors of physical or environmental risk in the field of the manufacturing of PVC boots; this project aims primarily to establish a hearing conservation program for workers in production area of MILBOOTS Company as a part of the management system of safety and health at work, which contributes to the prevention of occupational hearing diseases as a result of daily exposure. Occupational noise levels in the organization are in the maximum permissible levels by current legislation in Ecuador (Executive Decree 2393), which results in a decrease in hearing ability of its employees; for proposing this hearing conservation program the levels of industrial noise in the production plant were measured and then an assessment was made. To counteract the physical noise risk factor, it is proposed to establish a hearing preservation program (as a document according to the company's quality management system) containing the following information: a procedure for the identification and qualification of occupational noise , a procedure for the measurement and evaluation environmental risks factor, an instruction for the attenuation of the physical risk factor through the application of acoustic walls, an instructive for the selection of hearing protectors as a personal protection equipment and an instructive for the determination of hearing impairment according to the years of exposure to the work noise of the collaborators of the organization who carry out their activities in the production area, of course all the procedures and instructions must be accompanied by their respective records. The hearing conservation program (with its respective procedures, instructions and records), has been raised for application in the company, according to applicable international regulations.
