Ingeniería en Sistemas, Electrónica e Industrial

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/1

Examinar

Resultados de la búsqueda

Mostrando 1 - 2 de 2
  • Item type:Ítem,
    Gestión avanzada de inventarios de productos terminados mediante Business Intelligence con power BI en la microempresa productos lácteos Marlen
    (Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas Electrónica e Industrial. Carrera de Ingeniería Industrial., 2026-07-01)
    Vargas Salinas, Edwin Francesco
    ;
    Aldas Salazar, Darwin Santiago
    ;
    Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas Electrónica e Industrial. Carrera de Ingeniería Industrial.
    This degree project was developed with the purpose of designing an advanced inventory management model for finished products through the use of Business Intelligence tools in Power BI, applied to the microenterprise Productos Lácteos Marlen. The research began with an analysis of the current inventory management process, which revealed weaknesses in the manual recording of product inflows and outflows, limited traceability of information, and the absence of indicators to support operational decision-making. In addition, the ABC classification was applied to identify the products with the highest relevance for inventory control. To build the proposed model, the inventory data were first structured in Excel and then processed in Power Query to clean, organize, and standardize the information. After this stage, the data were connected to Power BI through a relational model that allowed the calculation of inventory control parameters using DAX formulas. These parameters included minimum stock, safety stock, reorder point, and maximum stock. Likewise, performance indicators were defined to evaluate inventory level, stock duration, turnover, the relationship between outputs and inputs, and compliance with established control parameters. The developed control panels allowed a clearer interpretation of inventory behavior by showing the condition of each product according to its availability level. This made it possible to distinguish products that required immediate attention, timely replenishment, regular monitoring, or adjustments due to excess stock. Based on these results, operational actions were proposed to support production planning, replenishment, and dispatch activities. Therefore, the proposed model contributes to improving inventory control, reducing dependence on empirical decisions, and promoting a more organized, preventive, and data-oriented management system.
  • Item type:Ítem,
    Estudio de los niveles de radiación electromagnética en la Facultad de Ingeniería en Sistemas, Electrónica e Industrial
    (Universidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Carrera de Telecomunicaciones, 2024-08)
    Valverde Sánchez, Edwin David
    ;
    Cuji Rodríguez, Julio Enrique
    The development of technology, together with the constant increase in energy consumption, generates the need to evaluate and storage of this energy from the environment. There is not much research on how to capture and efficiently use this energy. To measure the non-ionizing radiation in the FISEI campus, recurrent and sporadic nodes were determined in which a measurement of the immission electric field was taken in a wide band between 50 MHz and 3.5 GHz during 6 minutes in the morning, half day and afternoon during a period of 4 weeks using PCE EM 29 instruments. Finally, the data is transferred to ArcGIS to create a radiation diagram using the kernel interpolation method. Nodes with high electric field level were identified in Agora (0.665 V/m), Hall E (0.568 V/m), Garden 1 (0.427 V/m) and Car Park (0.389 V/m). The radiation diagrams show that the areas near the Access Points exhibit elevated levels of electromagnetic radiation. However, these levels do not exceed safe limits according to ARCOTEL regulations. Energy harvesting tests show that areas with higher radiation generate significant voltage gains (0.307 V), demonstrating higher energy harvesting efficiency compared to areas with lower radiation.