Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
5 resultados
Resultados de la búsqueda
Item type:Ítem, Comportamiento frente al fuego de paneles de caña guadua de viviendas tradicionales en la costa ecuatoriana(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2025-02) ;Jiménez Tenorio, Valeria de los ÁngelesParedes Beltrán, Bolívar EduardoThe use of various materials in the construction of houses has driven the need to study their behavior against events that can cause significant damage to structures, with the aim of preventing disasters. The main objective of this research work was to characterize the fire behavior of guadua cane panels (Guadua Angustifolia Kunth) used in light constructions on the Ecuadorian coast. Through an experimental methodology, the first phase determined the physical and mechanical properties of the material. In addition, the second phase focused on the NTE INEN-ISO 11925-2 standard, subjecting a total of 24 samples to the direct action of a flame. These samples, cut in longitudinal and transverse orientation, were evaluated both at the edge and on the surface, under two flame exposure times of 30 seconds, according to the standard and 120 seconds by experimental criteria. Finally, in the third stage, the flammability and carbonization indices were calculated from the data obtained. The results indicated that the guadua cane panels have an average density of 741.211 kilograms per cubic meter and a moisture content of 14.9 percent, meeting the basic requirements for use in low structural demand applications. In terms of mechanical properties, a tensile stress of 90.2 mega pascals, compression of 33.92 mega pascals and bending of 47.21 mega pascals were determined. Flammability tests demonstrated that the material exhibits favorable behavior against small flames under controlled conditions, with an average carbonization index of 3.1 percent and a limited contribution to fire classification (class "D" according to EN 13501-1). Although direct experimental tests were not performed with flame retardants, such as sodium octaborate tetrahydrate, the literature reviewed indicates that its application could significantly improve the fire resistance of guadua cane. This aspect should be investigated in future studies to determine its efficiency in construction applications. In conclusion, guadua cane is presented as a sustainable and viable alternative for construction in contexts of low structural demand, provided that preventive treatments are implemented and specific regulations are met. It is recommended to promote additional research, train professionals in the sector and promote sustainable management strategies for this renewable course.Item type:Ítem, Caracterización del comportamiento frente al fuego de la madera con recubrimiento de barniz utilizados en obra civil(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2025-02) ;Yugcha Lema, Jonathan AndrésViscaíno Cuzco, Mayra AlexandraThe use of wood coated with varnishes for flooring and wall coverings is widespread in the construction industry. However, its behavior in the event of a fire has been little studied, raising significant questions about its performance in fire scenarios. This research aims to characterize the behavior of Mascarey wood under fire conditions, considering its physical, mechanical, and thermal conductivity properties in three states: natural, coated with Monto brand high-gloss varnish, and coated with Condor brand Espengloss floor lacquer. Physical properties such as color and density were evaluated according to ASTM D 1535 and ASTM D2395 standards, respectively. Mechanical properties were assessed through parallel compression, perpendicular compression, and hardness tests, following the procedure described in ASTM 143-94. Additionally, a fire reaction test was conducted according to the NTE INEN ISO 11925 – 2 standards, using 18 Mascarey wood specimens with a thickness of 20 mm subjected to direct flame exposure, both on the edge and surface. The results indicate that the density of Mascarey wood increased by 4.5 percent when treated with coatings compared to its natural state. Regarding mechanical properties, specimens coated with Monto varnish showed a decrease in parallel and perpendicular to fiber compression resistance, with values of 47.97 N/mm2 and 13.71 N/mm2, respectively. Conversely, specimens coated with Espengloss lacquer showed an increase in these properties, reaching values of 50.03 N/mm2 in parallel compression and 15.06 N/mm2 in perpendicular compression, compared to natural specimens, which recorded values of 48.33 N/mm2 and 14.78 N/mm2, respectively. In terms of hardness, natural Mascarey wood presented the highest values in all three evaluated directions, with a notable value of 1013 kgf in the direction parallel to the fiber. However, in coated specimens, the highest hardness was observed in the radial direction, with values of 647 kgf for specimens coated with Monto varnish and 864 kgf for those coated with Espengloss lacquer. Furthermore, the thermal conductivity of coated Mascarey wood showed a 10 percent increase compared to uncoated specimens. In the fire reaction test, the vertical flame propagation did not exceed 150 mm in any case, classifying Mascarey wood as class D according to the EN 13501-1 standard, both in its natural state and with coatings. Although the coatings did not influence the flame propagation rate, they significantly reduced the carbonization rate. Specimens coated with Espengloss lacquer and Monto varnish recorded a carbonization rate of 0.14 and 0.19 percent, respectively. In contrast, natural specimens recorded a carbonization rate of 0.34 percent.Item type:Ítem, Comportamiento frente al fuego del bahareque de viviendas patrimoniales en la sierra del Ecuador(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2025-02) ;Guaraca Freire, Joel AdrianParedes Beltrán, Bolívar EduardoBahareque is a traditional construction technique widely used in Ecuador due to its low cost and sustainable approach. However, the houses built with this method present a high vulnerability to fire due to the nature of its main materials, reed, straw and mud. Despite their adaptability, these materials have not been sufficiently studied in terms of their reaction to fire, which represents a significant risk for the structures and their inhabitants. This research is focused on analyzing the behavior of wattle and daub in the face of fire, in order to provide relevant information to optimize its safety without compromising its cultural and heritage value. For this purpose, several tests were carried out in accordance with NTE INEN ISO 11925-2 and EN 13501-1 classification, to evaluate its flammability and establish its classification within the European standard. In addition to the reaction to fire tests, complementary tests were carried out, such as granulometric analysis, Atterberg limits, compressive strength and evaluation of the material's anisotropy. In total, 10 samples were tested for compression with dimensions of 300x100x100 mm, and 12 samples were tested for fire test (six edge tested and six surface tested) with dimensions of 250x90x50 mm. The variability in the arrangement of the reed in the samples allowed evaluating the influence of the orientation of the material on fire propagation. The tests showed that the initial fire propagation speed in the wattle and daub was 0.41 mm/s, reducing to 0.29 mm/s and 0.2 mm/s after 300 seconds, according to NTE INEN ISO 11925-2 tests. Thermal conductivity analyses confirmed its moderate insulation, which slows the spread of fire. With a compressive strength of 9.17 kg/sq cm, the wattle-and-daub is suitable for non-load-bearing walls. Finally, its Euroclass B classification according to EN 13501-1 indicates that the material can withstand a small flame for a long time without significant flame spread, which supports its viability as a sustainable building material.Item type:Ítem, Caracterización de la flamabilidad de los materiales de revestimiento utilizados en construcción, ensayados a borde(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-08) ;Valdez Pombosa., Anthony AbelPeñafiel Valla, Lourdes GabrielaThe new coating techniques have been used significantly in constructions, in such a way that their behavior against fire has not been considered, which raises questions regarding fire events. From the above, this investigative work was developed on fire reaction tests of construction materials such as Gypsum/ceiling and melamine subjected to the direct action of the fire flame according to the NTE INEN-ISO 11925 standard. 2, for which the physical properties of each material were analyzed and subsequently tested on edge for 30 seconds. In addition, a total of 36 samples were obtained, taking into account 18 specimens of each material with their 3 respective thicknesses, and 3 sectioned longitudinally and 3 transversely, in order to know if the direction of application of the material influences the its flammability. As a result, it was obtained that the melamine materials present an initial ignition, which does not occur with the Gypsum/ceiling materials. It was also evident that the vertical propagation of the flame does not reach the height of 150mm, consequently according to the behavior against the fire and according to the physical properties, each material was classified according to the EN 13501- 1 standard, where Gypsum/ceiling was categorized in class type C, and melamine in class type D, highlighting that all these materials for the production of smoke It is class type S3 and for the fall of inflamed droplets/particles it is class type D2.Item type:Ítem, Caracterización de la inflamabilidad de los materiales de revestimiento utilizados en construcciones, en base a sus propiedades físicas(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-02) ;Torres Morales, Stalin PatricioPeñafiel Valla, Lourdes GabrielaNew trends in coatings such as Gypsum, Ceiling and Melamine have been used more frequently in buildings today, but it has not been possible to analyze their behavior when faced with an ignition source, their reaction to fire and their contribution in the event of a fire. Based on this, an investigation of the reaction to fire of these materials was carried out with the application of a direct flame to the surface for 30 seconds and they were classified according to the Euro classes that determined the characteristics and behavior of the material in front of a flame; For which 36 samples were tested, 18 plaster samples in 3 different thicknesses and 18 melamine samples in 3 thicknesses, the same are applied in Gypsum, Ceiling, wall covering, among other uses; the samples were extracted 3 in longitudinal direction and 3 transversal for both materials, with the purpose of knowing if the direction of application of the material influences its combustion. As a result, it was found that no sample reaches initial ignition and the flame does not reach 150 mm in height, which is the maximum range established by the NTE INEN ISO 11925-2 standard. Based on this, Gypsum was classified as class C and melamine as class D, highlighting that for smoke production it is s3 and flaming droplets is d2, where these two materials do not declare any behavior.
