Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 10 de 14
  • Item type:Ítem,
    Análisis y diseño comparativo de sistemas de resistencia lateral en edificios de mediana altura para la evaluación sísmica en el sector El Obrero en la ciudad de Ibarra
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01)
    Lloré Cárdenas Pablo Stalyn
    ;
    Cevallos Cabrera Jorge Washington
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This research comparatively evaluates the seismic performance of two lateral force-resisting systems applied to a mid-rise building located in the El Obrero sector of Ibarra, under the provisions of the proposed NEC-26 standard. The study aims to determine the most efficient structural alternative considering the geotechnical conditions and seismic hazard characteristics of the area. The methodology involved the modeling of a six-story building using two structural configurations: a dual system with reinforced concrete shear walls and a concentrically braced frame system using X-bracing (Saint Andrew’s Cross bracing). Due to the instability of the original moment-resisting frame model, which exhibited critical torsional coupling and inelastic story drifts of up to 2.62%, the structure was stabilized through these two lateral force-resisting systems for subsequent analysis and nonlinear performance evaluation. The results showed that both alternatives corrected the stiffness deficiencies and controlled interstory drifts below the allowable limit of 1.50%. However, the inelastic evaluation revealed significant differences in ductility and energy dissipation capacity. The braced system exhibited high initial stiffness associated with a brittle failure mechanism and a premature reduction in its load-carrying capacity. In contrast, the dual system with shear walls demonstrated more ductile behavior, achieving a performance level corresponding to Immediate Occupancy. It is concluded that the dual system constitutes the most suitable alternative for similar buildings in Ibarra, providing improved seismic performance and greater structural resilience.
  • Item type:Ítem,
    Comparación del comportamiento sismo resistente de una edificación en estructura metálica con elementos verticales tipo HEB vs. perfiles tubulares.
    (2025-12-03)
    Silva Miranda, Julio César
    ;
    Medina Robalino, Wilson Santiago
    This research focuses on analyzing the seismic resistance of three structural systems with different vertical elements: concrete-filled columns, tubular columns without filling, and HEB columns. Their performance, dimensions, and costs were evaluated. Structural analyses were performed, including static, dynamic, and nonlinear evaluations, using standards such as NEC 15, FEMA 440, and ASCE 41-17, confirming that all three designs satisfied seismic safety and performance criteria, reaching a level of Life Safety in the design earthquake. The performance analysis also determined that the frame with HEB columns and bracing showed the greatest resistance, followed by unfilled tubular columns. The tubular columns filled with concrete ranked as third in terms of performance. The seismic joints were designed and analyzed using Idea Statica software, which illustrated energy dissipation in optimal areas. For the cost analysis, a comparative cost study was conducted based on A572 Gr.50 steel, which is used to build the columns, and concrete. The results showed that the most economical system is the tubular columns filled with concrete, with a cost of $1,172,639.67, because of a lower steel weight and with less plates. The columns with HEB sections were in second place, with a cost of $1,752,035.49, and finally, tubular columns, with a value of $2,253,024.43. In conclusion, the analysis shows that the design with HEB columns and bracing has the best seismic performance, while the system of concrete-filled tubular columns offers a better economically viable solution for the characteristics of this type of building.
  • Item type:Ítem,
    Comparación del comportamiento sismo resistente de una edificación en estructura metálica con elementos verticales tipo HEB vs. perfiles tubulares
    (Ingeniería Civil y Mecánica. Carrera Ingeniería Civil. Maestría con mención en Estructuras Metálicas, 2025-12-02)
    Silva Miranda Julio César
    ;
    Medina Robalino Wilson Santiago
    This research focuses on analyzing the seismic resistance of three structural systems with different vertical elements: concrete-filled columns, tubular columns without filling, and HEB columns. Their performance, dimensions, and costs were evaluated. Structural analyses were performed, including static, dynamic, and nonlinear evaluations, using standards such as NEC 15, FEMA 440, and ASCE 41-17, confirming that all three designs satisfied seismic safety and performance criteria, reaching a level of Life Safety in the design earthquake. The performance analysis also determined that the frame with HEB columns and bracing showed the greatest resistance, followed by unfilled tubular columns. The tubular columns filled with concrete ranked as third in terms of performance. The seismic joints were designed and analyzed using Idea Statica software, which illustrated energy dissipation in optimal areas. For the cost analysis, a comparative cost study was conducted based on A572 Gr.50 steel, which is used to build the columns, and concrete. The results showed that the most economical system is the tubular columns filled with concrete, with a cost of $1,172,639.67, because of a lower steel weight and with less plates. The columns with HEB sections were in second place, with a cost of $1,752,035.49, and finally, tubular columns, with a value of $2,253,024.43. In conclusion, the analysis shows that the design with HEB columns and bracing has the best seismic performance, while the system of concrete-filled tubular columns offers a better economically viable solution for the characteristics of this type of building.
  • Item type:Ítem,
    Análisis del desempeño sísmico del edificio de hormigón armado Hotel Dubai Ambato, Provincia de Tungurahua
    (Ingeniería Civil y Mecánica. Carrera Ingeniería Civil, 2025)
    Chimborazo Sigcha Edison Ariel
    ;
    Medina Robalino Wilson Santiago
    The purpose of this study was to evaluate the seismic performance of the reinforced concrete Hotel Dubai Ambato, located in the Catiglata sector, considering current Ecuadorian regulations. A qualitative and quantitative methodology was used for a comprehensive diagnosis of the existing structure and determination of its seismic performance. The structural analysis using critical linear procedures revealed that the building presented medium seismic vulnerability, primarily associated with structural irregularities and deficiencies in key elements. Maximum lateral drifts of 3.65% and 3.44% were identified in the static and dynamic analysis, exceeding the established limits, and elements that did not meet the load demands, compromising structural safety in severe earthquakes. Furthermore, a nonstatic line analysis (Pushover) verified that the building, in its original state, did not meet the established performance objectives. It was located at critical levels for certain seismic scenarios, reaching the level of collapse in a rare design earthquake, with maximum displacements of up to 27 cm and the formation of plastic hinges on the first three levels. As a solution, a structural reinforcement was proposed, including the incorporation of 25 cm thick shear walls and metal casing of columns with steel angles and plates. After the intervention, the drifts decreased to a maximum of 1.81%, falling within regulatory limits. These interventions also ensured the elements met safety parameters. This resulted in the structure showing reduced maximum displacements and a greater capacity to withstand seismic forces, demonstrating increased structural rigidity and capacity, meeting seismic performance objectives for all established seismic hazard levels
  • Item type:Ítem,
    Análisis del desempeño sísmico del edificio cooperativa de ahorro y crédito Chibuleo ubicado en el cantón Machala
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-02)
    Pintag Quitio, Esau Ernesto
    ;
    Ramírez Cabrera, Wladimir José
    Through scientific research, it is understood that a linear static analysis was not enough to understand the behavior of a structure, hence the need to analyze it under a non-linear regime. The present experimental work for its development was carried out in 4 phases: Initial phase, consisted of collecting all the necessary data of the building, structural and architectural plans, destructive tests of concrete and steel, determining the mechanical properties of the material with their respective control reports. quality, for verification, with the purpose of implementing a three-dimensional mathematical model in engineering software. For the first, the structural response was analyzed through linear seismic analysis, verifying: vibration period, participatory mass, plan torsion, static basal shear, dynamic basal shear, floor derivatives, structural elements (beams, columns) and seismic resistance criteria according to per NEC-SE-DS-15. For the second, the capacity curve was calculated using Pushover analysis and the behavioral objectives proposed by the VISION 2000 committee for a frequent, occasional, rare and very rare earthquake were evaluated using the ASCE 41 coefficient method. 13. As a result, in phase 3, an optimal strengthening method at the structural element level was proposed, according to the data of linear seismic analysis and nonlinear static seismic analysis, and the analyzes of phases 1 and phase 2 were carried out again. .in order to check if the reinforcement was optimal for the building.
  • Item type:Ítem,
    Estudio comparativo del diseño sismo resistente de una edificación de estructura metálica de cinco pisos con arriostramientos concéntrico y excéntrico en la Unidad Educativa Tres de Marzo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Sanabria Espinoza, María Natividad
    ;
    López Arboleda, Alex Gustavo
    The objective of this work was the comparative study of the seismic behavior of buildings with two bracing systems. In Ecuador there are different zones with seismic danger, for this reason, recently improvements have been implemented in the design and construction of steel structure buildings, some of these improvements are the implementation of bracing systems. Although this practice is very useful to improve the seismic behavior of buildings, locally its performance is still being studied. In the analysis proposed in this work, concentric bracing (in X and V) and eccentric bracing (in X and V) were considered for a specific zone. In order to analyze the seismic behavior of the building, the soilstructure conditions were applied with the characteristics of the Chimbo canton that were compiled from a soil study, additionally, a basic building was configured, in which the 4 different types of bracings were applied in order to identify if there is a system that presents a better performance. A Pushover analysis was applied to all configurations to establish which system provides the best results. Finally, it was identified that the inverted V bracings provide the building with greater flexibility without the need to compromise its integrity.
  • Item type:Ítem,
    Evaluación de la vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Izamba (Zona 3), Ambato, Ecuador. Propuesta de reforzamiento estructural de una edificación representativa
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Vargas Aráuz, Ángela Verónica
    ;
    López Velástegui, Jorge Enrique
    This research work shows the application of the rapid visual inspection methodology according to FEMA P-154, with which it is possible to identify, inventory and examine the possible seismic risks of the buildings evaluated and with this information decide if a detailed structural evaluation is necessary. The seismic vulnerability according to FEMA P-154 is expressed in terms of the probability of collapse of the structure, with this information you can manage contingency plans before and after earthquakes and inform the owner of the building the status and possibility of structural reinforcement. After carrying out the evaluation of the selected buildings, a representative structure was determined located in the Izamba parish of the city of Ambato, which was chosen for its level of importance and based on the results of the previous evaluation. With the data obtained from the rapid visual inspection and the documentation obtained from the representative building, a linear static analysis was carried out, with the application of the Ecuadorian construction standard, to determine the current behavior of the structure according to its efforts, displacements, and maximum permitted drifts. The structural analysis determined that the building presents great flexibility and fails in some members such as beams and columns. As a solution to the problem detected, structural reinforcement was chosen with steel diagonals to increase the rigidity of the structure and incorporate additional structural members that support seismic actions. The research was completed by performing the nonlinear static analysis known as Pushover of the reinforced building, from this analysis the capacity curve is obtained and the probable performance of the structure before the design earthquake can be verified.
  • Item type:Ítem,
    Análisis técnico económico del coeficiente de reducción de respuesta estructural con aplicación y comparación en sistemas aporticados de estructuras metálicas
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Jácome Guanopatín, Ángel Patricio
    ;
    Cañizares Ortega, Freddy Fernando
    In this degree work, the analysis and calculation of the seismic reduction factor for a structure with special moment frames (PEM or SMF) composed of four different mathematical models where the seismic reduction factor changes with values of R=8, 6, 4, 5 and 3. 5 and 3; performing the dynamic linear structural analysis of the four models, each structure changes according to the demand required by the seismic forces, determining that the lower the value of R the larger sections are required in the structure, in spite of the above, the fundamental vibration period of the structures was maintained for R= 8, 6 and 4. 5, while for the factor R=3 the period is slightly reduced resulting in a stiffer structure, as the seismic response factor is reduced, more robust sections are required to provide more weight to the structure to meet the demand. An economic analysis was performed with the sections obtained, which shows that the lower the R value, the structure requires a higher weight and therefore influences a higher cost, so the structure with the lowest cost is the structure with an R=8. Additionally, a pseudo-static non-linear analysis was determined to determine the structural performance of each of the four models using the ATC-40 and FEMA- 440 methods, highlighting that the models maintain the same architectural and geometric configuration but with different sections in certain elements that required a higher geometry as the R value decreases, after obtaining the results of the static non-linear analysis, the performance point was determined using the ASCE 41-17 and FEMA 440 (2005) methodology, resulting in the R=8, 6, 4. 5 and 3 for 475 years has a performance level in X and Y of immediate occupancy. For the determination of the structural response factor, the methodology proposed by Dr. Aguiar 2006 was followed, which is similar to that of ATC-19 (1995), where the ductility, resistance and redundancy factor is determined, data that are collected from the performance point obtained for the elastic design spectrum with a return period of 475 years, the structural response factors R obtained establish that the average range is between 6 and 7.5, on the other hand the structure that presents greater capacity and performance is the one that was designed with R=4. 5 so having extremely rigid sections does not guarantee stability and ductility in a structure, finally a high level of performance (immediate occupation) and seismic energy dissipation capacity is established in the structure designed with a R=6 where its value is similar and slightly lower than 4.5, so it is concluded that for a structure of special steel composite moment frames a design with a structural response factor equal to 6 should be sought.
  • Item type:Ítem,
    Comparación de la respuesta sísmica entre pórticos especiales a momento y pórticos arriostrados excéntricamente, en un edificio de acero de 10 pisos, en el cantón Ambato, provincia de Tungurahua
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Aleaga Del Salto, Luis Alfonso
    ;
    Guevara Robalino, Jorge Javier
    Ecuador is a country of high seismic danger; therefore, the calculation of structures will always be a challenge for engineers since every day new advances in science and technology emerge, making it possible to predict the behavior of a building in extreme events such as earthquakes; in this work the Ceinci-Lab Computer System has been used, which allowed to perform analysis and design of structures step by step obtaining clear and accurate results. The objective of this research is to compare the seismic response between special moment frames and eccentrically braced frames in a 10-story steel building. A simple and regular structural configuration was used to obtain a better seismic performance of all the components of the system. Subsequently, the seismicresistant analysis of the frames was carried out with the different structural configurations proposed in the Ceinci-Lab computer program, using the linear modal spectral and static equivalent analysis for its resolution and complying with the guidelines established in the Ecuadorian construction standard and international codes; finally, it was determined that the building composed of eccentric diagonals had a better seismic response than the one composed of moment resisting frames, obtaining lower displacements and floor drifts; It was also verified that the demand versus capacity of each system is optimal, thus ensuring a strong column - weak beamxvii behavior; additionally, a nonlinear pushover analysis was performed to determine the real maximum resistance of the structure and the performance of all its components; therefore, it is essential to consider the use of bracing in the structural configuration of medium-rise buildings, especially with short link elements, since they act as energy dissipaters, improving the stiffness and global response of the system in severe earthquakes.
  • Item type:Ítem,
    Análisis estructural del desempeño sísmico del edificio de Ciencias Aplicadas de la Universidad Técnica de Ambato, campus Huachi
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2022-09)
    Gutiérrez Claudio, Danny Alexander
    ;
    Cevallos Cabrera, Jorge Washington
    Ecuador is located in an area of high seismic hazard, therefore it is necessary to carry out an evaluation of the seismic performance of existing buildings. For this purpose, the study was carried out in the Applied Sciences building of the Technical University of Ambato, Huachi Campus. The performance analysis began with a quick visual inspection applying the FEMA P-154 and NEC 2015 forms, where the result of this technique corresponded to a medium-grade seismic vulnerability. Next, a spectral modal analysis was carried out, through which it was determined that the structure does not meet the earthquake resistance parameters established by the NEC 2015, therefore it was considered necessary to propose a reinforcement of the structure. At the level of global reinforcement, type V braces were implemented at levels N+3.24m to level N+ 16.20m in order to stabilize the structure. At the local level, in beams and columns, a sheathing of the structural elements was proposed through angles and steel plates. Analyzing the reinforced structure, it was verified that it complies with the NEC 2015 guidelines. Once the structure was stabilized, a non-linear static analysis or Pushover was carried out, verifying that it reached the objectives determined by the NEC 2015, for a rare earthquake the performance point is at the operational level, while for a very rare earthquake the performance is in collapse prevention.