Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
5 resultados
Resultados de la búsqueda
Item type:Ítem, Estudio del comportamiento sísmico de la interacción suelo-cimentación en una estructura metálica representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-10) ;Morales Zúñiga, Humberto RamiroRamírez Cabrera, Wladimir JoséEcuador is located in an area of high seismic hazard, mountainous terrain, slopes of low, medium and high slopes in the Sierra region mainly, the high housing deficit and without considering the danger of founding the structures in this type of soil, the human being makes disorderly settlements and without any planning and control by government entities, This is why it is necessary to carry out a comprehensive technical analysis to determine the favorable response of the building to a dynamic event in a sloping terrain. The factors involved in the dynamic soil-structure interaction were analyzed, such as accelerations, velocities, displacements, the relationship between them and the variations in the fundamental period of the structure when considering the flexibility of the foundation soil; For which through the use of springs and dampers (impedance functions) that represent the dynamic response of the IDSE system based on the Barkan model and the NEC-15, the increase of the flexibility in the foundation base of the soil-structure interaction model, with respect to the rigid base model in a type D soil, was determined by means of dynamic and experimental simulation. As a consequence of the present research work, a notorious change in the behavior of the foundation of the structure was obtained, which was subjected to the load solicitations initially proposed and related to the traditional rigid base model. The results of the present study can be used to improve design and construction techniques, in addition to providing relevant information to professionals in the engineering field on the soilfoundation interaction of structures. In order to extend the analysis of the aforementioned conditions, an analysis of the soil-structure behavior can be included in future research.Item type:Ítem, Desempeño de estructura metálica mediante análisis dinámico con acelerogramas ajustados con espectro medio condicional (CMS)(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09) ;Pérez Galarza, Christian DaniloChérrez Gavilanes, Diego SebastiánThe present investigation is carried out in Huachi Loreto in Ambato city, starting as a first point, to identify the geological faults near this study site that can contribute to generate a seismic event that affects the structures in the area. Using empirical formulas, the value of the shear wave velocity was obtained based on calculated values, specific to the site, such as the length of the fault, source - study distance, focal depth, expected moment magnitude, and values of the number of blows of the SPT test performed in situ. This shear wave velocity allows determining the type of soil existing in the area according to the ranges established by the Ecuadorian Construction Standard (NEC 2015). Subsequently, an attenuation model was chosen (Montalva) that allows to determine, by applying certain equations called GMPEs (ground motion prediction equations), a possible behavior of the soil based on complementary data to those already mentioned specific to the site such as distance and hypocentral depth. From the GMPE graph and the uniform hazard spectrum (UHS) and applying certain equations determined in the Bakker model, the conditional mean spectrum (CMS) was obtained. The use of this spectrum allowed a comparison of the behavior of a metallic structure proposed in this study, with respect to the elastic spectrum imposed by the NEC. This comparison was made on the basis of the results provided by the nonlinear dynamic analysis (time-history), through which the performance of the same structure subjected to scaled seismic events was determined with respect to the CMS and the NEC spectrum. It was obtained as a result that the seismic demand produced by the NEC spectrum is greater than that produced by the CMS, since the pseudospectral accelerations have a great difference between these spectra, which is why the maximum displacements and drifts are reduced by approximately 65 percent by applying the CMS in the present investigation.Item type:Ítem, Análisis estático no lineal (Push Over) de los talleres de la Facultad de Ingeniería Civil y Mecánica y de la Facultad de Ingeniería en Sistemas Electrónica e Industrial, con aisladores sísmicos, ubicadas en el campus Huachi de la Universidad Técnica de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022) ;López Sánchez, Byron LeonardoUreña Aguirre, Maritza ElizabethThis research work presents a comparative analysis of the structural behavior of a conventional structure and another with the implementation of seismic isolators, which are devices that allow the building to deform elastically and dissipate energy during the occurrence of earthquakes of considerable magnitude. The structures analyzed were the workshops of the faculties of: Civil and Mechanical Engineering and Systems, Electronics and Industrial Engineering and they are classified as special according to the Ecuadorian Construction Standard (NEC 2015), and present a structural system of special earthquake resistant gantries made of hot rolled steel with stiffening diagonals, they are also used as laboratories for the production area and as a higher education center.xxiii As a first study, a linear analysis of the structures was performed to verify their current state by analyzing their vibration period, displacements and permissible drifts, then a non-linear static analysis was performed to determine their seismic performance, and then the isolation system was pre-dimensioned. It was designed taking as a priority the ASCE/SEI 7-10 standard, the dead loads of the building plus 30 percent of the live load above the isolation system and based on the information provided by the manufacturer. It should be taken into account that there are a large number of options of anti-seismic devices to improve the performance and behavior of a structure; in this case study, the lead core elastomeric isolator (LRB) was chosen. Subsequently, all the established limits such as drifts, shear and displacements were verified, taking into account the provisions of the Ecuadorian Construction Standard. For the workshop of the Faculty of Civil and Mechanical Engineering with isolated base, the floor drifts were reduced by 64 percent compared to the structure without isolation, for the basal shear and horizontal displacements a reduction of 73 and 51 percent respectively, likewise for the workshop of the Faculty of Systems, Electronics and Industrial Engineering the floor drifts, shear and displacement were reduced by 69, 74 and 63 percent respectively.Item type:Ítem, Estudio de pórticos arriostrados concéntricamente en V, V invertida y arriostramiento en K y su incidencia en el diseño de un edificio en acero de 7 pisos(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-03) ;Salinas Villegas, Edisson XavierEspín Lagos, Segundo ManuelIn this research paper, a comparison was made between three types of bracing: in V, in Inverted V and in K of a 7-story building with the possibility of applying it in our environment as it is in the city of Ambato and also so that can be used at the national level since both national and American regulations were used. The pre-designs of the structural elements were made, both for the columns, main and secondary beams, collaborating plate, and the bracing elements to then carry out their respective design, first checking their compactness and slenderness in each of their elements. Through the use of finite element software, each of the structural elements was modeled, entering properties and specifications to its elements, a static and dynamic analysis was carried out, for which the load combinations were defined, and also the load spectrum. design, as well as the configurations of the structure in plan and elevation, in addition to the seismic zone according to the project that is being investigated, all this so that the 7-story structure is earthquake resistant and each of the checks stipulated by the Ecuadorian Construction Standard (NEC 2015). Comparisons were also made with the three different types of bracing and the price of the structure was analyzed. Finally, it was concluded that the best type of structure was the inverted V bracing, because it has a lower drift than the previous two with values less than two percent and has a good structural behavior compared to the other checks carried out as in the dynamic analysis that complies with a percentage greater than 80 percent, the rotational analysis less than 30 percent in both X and Y; and the participation of the mass greater than 90 percent.Item type:Ítem, Análisis comparativo del diseño sismo resistente de estructura de hormigón armado basado en normativa ecuatoriana (NEC-SE-DS) y colombiana (NSR-10)(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2022-03) ;Gallegos Díaz, Pablo FernandoUreña Aguirre, Maritza ElizabethThis paper focuses on reviewing the technical aspects and weaknesses of seismic resistance codes in Ecuador and Colombia. Within each code, the scopes, factors, and parameters involved in determining the design spectrum and the design basal shear. It is intended to analyze the structure through the Etabs software, for this, the most relevant parameters are collected: location, site factors, the structural system, the design spectrum and the design base shear to model the building according to the requirements required by the codes. Then, the dynamic analysis was performed to determine the fundamental period of the structure and verify them with the limits of the corresponding study codes. In the event of non-compliance, the dimensions of the structural elements shall be increased and the analysis carried out again. Finally, the results of the seismic response were compared: vibration periods, horizontal displacements, dynamic shears and story drifts, where the last three are significantly affected by the design shear; will see the requirements of each code, coming to know if our Ecuadorian norm is projected to be more rigorous than the Colombian regulation.
