Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 10 de 25
  • Item type:Ítem,
    Evaluación comparativa de una edificación de ocupación especial, diseñada en hormigón armado y en acero estructural, aplicando un análisis estático no lineal
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03)
    Capuz Yanzapanta Franklin Roberto
    ;
    Navarro Peñaherrera Carlos Patricio
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This research focuses on analyzing the seismic resistance of two structural systems: reinforced concrete and structural steel. Their performance, dimensions, costs, and construction time were evaluated to identify the most resistant, economical, and efficient system from a construction standpoint. Structural analyses were performed, including static, dynamic, and nonlinear evaluations, applying the Ecuadorian standards NEC 2015, ASIC 341-22, and ASCE 41-17. The results confirmed that both systems meet the established seismic safety and performance criteria, achieving the Fully Operational level under the design earthquake. For the economic analysis, a comparative cost study was conducted between the two structural systems. In the reinforced concrete structure, the analysis focused on reinforcing bars with a yield strength of 4200 kg/cm² and plain concrete with a compressive strength of 240 kg/cm². In the steel structure, the study focused on A572 Gr.50 steel, 240 kg/cm² structural plain concrete, and 210 kg/cm² concrete for column infill, in addition to the use of a composite slab. The results showed that the reinforced concrete system has a higher construction cost, reaching $2,799,502.28 USD, while the steel structure proved to be more economical with a budget of $1,960,480.57 USD. In conclusion, the analysis demonstrates that steel structure designs offer greater economic profitability.
  • Item type:Ítem,
    Comparación del comportamiento sismo resistente de una edificación en estructura metálica con elementos verticales tipo HEB vs. perfiles tubulares.
    (2025-12-03)
    Silva Miranda, Julio César
    ;
    Medina Robalino, Wilson Santiago
    This research focuses on analyzing the seismic resistance of three structural systems with different vertical elements: concrete-filled columns, tubular columns without filling, and HEB columns. Their performance, dimensions, and costs were evaluated. Structural analyses were performed, including static, dynamic, and nonlinear evaluations, using standards such as NEC 15, FEMA 440, and ASCE 41-17, confirming that all three designs satisfied seismic safety and performance criteria, reaching a level of Life Safety in the design earthquake. The performance analysis also determined that the frame with HEB columns and bracing showed the greatest resistance, followed by unfilled tubular columns. The tubular columns filled with concrete ranked as third in terms of performance. The seismic joints were designed and analyzed using Idea Statica software, which illustrated energy dissipation in optimal areas. For the cost analysis, a comparative cost study was conducted based on A572 Gr.50 steel, which is used to build the columns, and concrete. The results showed that the most economical system is the tubular columns filled with concrete, with a cost of $1,172,639.67, because of a lower steel weight and with less plates. The columns with HEB sections were in second place, with a cost of $1,752,035.49, and finally, tubular columns, with a value of $2,253,024.43. In conclusion, the analysis shows that the design with HEB columns and bracing has the best seismic performance, while the system of concrete-filled tubular columns offers a better economically viable solution for the characteristics of this type of building.
  • Item type:Ítem,
    Comparación del comportamiento sismo resistente de una edificación en estructura metálica con elementos verticales tipo HEB vs. perfiles tubulares
    (Ingeniería Civil y Mecánica. Carrera Ingeniería Civil. Maestría con mención en Estructuras Metálicas, 2025-12-02)
    Silva Miranda Julio César
    ;
    Medina Robalino Wilson Santiago
    This research focuses on analyzing the seismic resistance of three structural systems with different vertical elements: concrete-filled columns, tubular columns without filling, and HEB columns. Their performance, dimensions, and costs were evaluated. Structural analyses were performed, including static, dynamic, and nonlinear evaluations, using standards such as NEC 15, FEMA 440, and ASCE 41-17, confirming that all three designs satisfied seismic safety and performance criteria, reaching a level of Life Safety in the design earthquake. The performance analysis also determined that the frame with HEB columns and bracing showed the greatest resistance, followed by unfilled tubular columns. The tubular columns filled with concrete ranked as third in terms of performance. The seismic joints were designed and analyzed using Idea Statica software, which illustrated energy dissipation in optimal areas. For the cost analysis, a comparative cost study was conducted based on A572 Gr.50 steel, which is used to build the columns, and concrete. The results showed that the most economical system is the tubular columns filled with concrete, with a cost of $1,172,639.67, because of a lower steel weight and with less plates. The columns with HEB sections were in second place, with a cost of $1,752,035.49, and finally, tubular columns, with a value of $2,253,024.43. In conclusion, the analysis shows that the design with HEB columns and bracing has the best seismic performance, while the system of concrete-filled tubular columns offers a better economically viable solution for the characteristics of this type of building.
  • Item type:Ítem,
    Diseño y análisis del comportamiento estructural de un edificio en la ciudad de Ambato mediante el uso de disipadores sísmicos.
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas., 2025)
    López Sánchez José Luis
    ;
    Cañizares Ortega Freddy Fernando
    This research project presents a comparative analysis of the seismic performance of a special building located in Ambato, utilizing Special Moment Frames (SMF) and Buckling-Restrained Braces (BRB). The main objective of the study is to evaluate the structural performance in terms of strength, capacity, stiffness, and nonlinear behavior under seismic loading. The proposed design for the steel structure incorporates BRB frames, aimed at minimizing deformations induced by seismic events. These systems utilize braces with ductile cores and replaceable assemblies, which enable efficient energy dissipation. The applied methodology is based on international standards such as AISC 360, AISC 341, NEC 15, and ASCE 41-17, covering literature review, soil analysis, load estimation, nonlinear time history analysis, and unit cost comparison. The results show that BRB systems offer superior seismic performance compared to moment-resisting frames, without involving a significant increase in implementation costs. However, it is important to note that the findings of this research are specific to the soil and loading conditions of the analyzed structure; therefore, further studies are recommended for other types of buildings and geotechnical contexts.
  • Item type:Ítem,
    Elaboración de curvas de fragilidad al colapso del bloque 1 del edificio del parqueadero de la Universidad Técnica de Ambato.
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas., 2025)
    Mopocita Cunalata Luis Ricardo
    ;
    Ramírez Cabrera Wladimir José
    Ecuador is located in areas of high seismic hazard due to its location on the Pacific Ring of Fire. For this investigation, an estimate of the probability of exceeding a certain damage level of the Block 1 parking lot was made by developing fragility curves upon collapse using a nonlinear dynamic time history (ADNL TH) analysis and considering incremental dynamic analysis curves. This investigation followed ASCE 41-17, FEMA P 58, and NEC 2015 guidelines. Through a spectral modal analysis, noncompliance with the strong column-weak beam criterion and torsion of the building in the second vibration mode was observed. The results witnessed a high probability of structural damage to the parking lot or collapse in component 2 (NS), with maximum nonlinear drift responses that do not reach the performance level for immediate occupancy (IO) and life safety (LS) for a return period of 72 years and 475 years. In addition, a total of 218 nonlinear dynamic timehistory simulations were performed at different seismic intensity increments. This research aims to promote the use and development of fragility curves as an alternative to ensuring the safety of those who use buildings or similar structures.
  • Item type:Ítem,
    Análisis de desempeño sísmico del edificio COAC San Martín ubicado en el cantón Tisaleo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil., 2025-02)
    Yugcha Rumiguano, Christian Sebastián
    ;
    Peñafiel Valla, Lourdes Gabriela
    Ecuador is located in the Ring of Fire, so it is subject to stochastic phenomena such as earthquakes, since buildings must be governed according to the current NEC 15 standard to ensure that the design meets earthquake resistance criteria. The purpose of this research work is to determine the seismic performance of the building under study. A qualitative analysis was carried out using the NEC 15 standard, in which the parameters were evaluated according to the characteristics of the structure, obtaining a score of 2.0, demonstrating that it has a medium degree of vulnerability. In the quantitative section, the linear and nonlinear static Pushover analysis of the structure was carried out using engineering software. In the linear analysis, it was determined that the structure in current conditions presents torsion, and that elements such as beams and columns are not designed to withstand the demands. In addition, through non-linear analysis, the capacity curve of the structure was calculated together with the performance levels and it was determined that the construction does not meet the seismic performance objectives according to VISION 2000. Once the evaluation of the structure was completed, three more floors were designed, according to the specifications of the calculation report, and with the requests of these, the structure was reinforced, both locally in the elements such as columns and beams using criteria from the ASCE 41-13 standard, in which the concrete screed method was used for the columns and the steel casing method for the beams, and globally with the implementation of shear walls to control torsion and comply with the vibration period of the structure. Finally, with the implementation of the reinforcement and the addition of 3 more floors to the building, the linear analysis was carried out again, to verify that the calculations and design were in accordance with the NEC 15 standard, checking that the elements had the necessary amounts of steel to generate ductility. After that, the non-linear analysis of the structure was carried out, in which the performance objective was determined, complying with what was established in VISION 2000.
  • Item type:Ítem,
    Análisis y diseño del comportamiento estructural de pórticos arriostrados excéntricos con vigas de enlace aplicado en un edificio de 7 pisos
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2024-10-01)
    Bayas Freire, Jorge Esteban
    ;
    Ramírez Cabrera, Wladimir José
    The purpose of this research project is the analysis and structural seismic design of a seven-story building with steel structure and composite columns filled with concrete, located in the city of Ambato with a irregular floor geometry through the implementation of eccentric braced frames (EBF) with link beams in both directions of the structure with a clear length of 60 centimeters. In this research a dynamic analysis of the structure was carried out in the Etabs software verifying parameters within the Ecuadorian construction standard NEC 15 such as floor drifts, strong column - weak beam criteria, then the design of the structural elements with spreadsheets was carried out complying with the ASIC 360-16, AISC 341-16 and ASCE 7-16 regulations, also the connections of both the link and beam-column of the structure were design through finite element analysis of the welding and the connection plates in the IdeaStatica software complying with the AWS D1.1 design regulations. Additionally, a non-linear static analysis (pushover) was performed in both directions of the structure applying incremental load patterns, the capacity curves and performance points for a rare earthquake and a very rare earthquake were determined, an evaluation of these points was carried out within the matrix established in the Vision 200 standard. Finally, it was possible to observe the real overall performance that the structure will have under seismic loads, thus verifying the behavior of the link as an energy dissipator through the formation of plastic hinges. The results obtained in this research project have demonstrated the correct earthquake-resistant design of the eccentric braced frames, obtaining a safe and efficient structural system.
  • Item type:Ítem,
    Determinación del desempeño sísmico del edificio ACT consultores, ubicado en la ciudad de Ambato a través del análisis no lineal push over
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-02)
    Cárdenas López, Fernando Josué
    ;
    Peñafiel Valla, Lourdes Gabriela
    Being located in a highly seismic area, any engineering work is exposed to the possibility of suffering great damage or even collapse under the action of seismic events, that is why the main function of this experimental work is to show the seismic performance of the ACT Consultores building located in the city of Ambato [1]. This work was carried out in three phases; the first one describes the characterization of the architectural and structural building, identifying the materials that were used. Then, the second stage is focused on information processing with the development of the qualitative method, which refers to a quick visual evaluation of the vulnerability of the structure, while the quantitative method refers to the whole process involved in the seismic-resistant design of a building to translate it into the engineering software. Also, the nonlinear analysis was performed by means of a Push Over to evaluate the seismic performance of the building under different levels of seismic hazard without the retaining wall. Finally, the third phase is based on the structural rehabilitation of the building. After reviewing that the building did not comply with period checks, interstory drifts, torsion and the performance point in a "Rare" earthquake was not as expected for basic constructions such as offices. Based on this, we proceeded to place shear walls to correct drifts, torsion, period and performance point so that the building would have better structural behavior.
  • Item type:Ítem,
    Análisis de vulnerabilidad sísmica y reforzamiento estructural del edificio Colineal, ubicado en la parroquia Atocha-Ficoa, cantón Ambato
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Romero Guamanquispe, Jorge Roberto
    ;
    Núñez Aldas, Galo Wilfrido
    In this degree work, as an initial part, a seismic vulnerability analysis of the metal structure buildings in the Atocha-Ficoa parish is carried out through quick visual inspections using the forms established by the Ecuadorian Construction Standard NEC-2015, FUNVISIS as well as by the Federal Emergency Management Agency of the United States FEMA P-154, since through this study it was determined that the houses in this parish present a medium-high vulnerability, Thus, the most representative building was selected, the Colineal company building, which presents technical-constructive observations of structural order such as fissures, cracks, detachment of plaster on walls and floors, which has caused a premature deterioration of the infrastructure. For this reason, an analysis was carried out by means of mathematical models through the ETABS computer program, where a linear analysis was performed to verify structural parameters such as drifts, displacements, and vibration periods. Subsequently, a non-linear static analysis (Pushover) was performed to determine the capacity of the structure and its performance level in the presence of a seismic event, to finally determine, based on the performance obtained, a structural reinforcement system by means of concentric diagonals, which will provide greater stability, ductility and resistance to the building and through this constructive alternative improve its seismic performance level and adequately meet the technical criteria for life safety.
  • Item type:Ítem,
    Análisis no lineal del puente de sección compuesta tipo de 135 metros de longitud usando SAP2000
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Calo Catota, Byron Patricio
    ;
    Romo Proaño, Luis Marcelo
    Given the importance of bridges for the road, social and economic development of the country, the design and verification of seismic performance is imperative; this project takes a first step towards that goal by understanding the nonlinear behavior of typical Ecuadorian composite bridges. For this purpose, the case study of a steel bridge built in 2020 and located in province of Los Ríos, Ecuador, has been taken as a case study. To achieve this objective, we have taken bibliography present in articles, guides and normative standards, especially international; the nonlinear responses of components such as: superstructure, columns, elastomeric supports, vertical seismic bars, passive response of the fill in abutments and seismic restraints are proposed and constructed with the objective of representing the real behavior of a bridge against the earthquake of April 16, 2016 occurred in Ecuador, specifically the one registered in the city closest to the project (Portoviejo). The nonlinear time response analysis is performed in the commercial program and the behavior of the bridge and is obtained considering the two orthogonal components of the earthquake. The results obtained are displacements, velocities and accelerations of the superstructure and pier, moment-rotation in the central pier, force-displacement curves of the non-linear elements such as vertical bars, supports, braces, etc. From the above, it is possible to determine that there would be impact between beams-shear keys, superstructure - abutments and in the joint separating the multispam simple supported; it is also observed that certain components present limited levels of displacement such as fillers, vertical bars and columns; on the contrary, the element that would present the greatest damage are the shear keys in the central pile and elastomeric supports, especially their lateral response. The analysis of each component was developed in detail and appended for academic purposes, so that future research can apply this methodology to the evaluation of new and existing bridges.