Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 3 de 3
  • Item type:Ítem,
    Análisis comparativo del comportamiento sísmico de una estructura de hormigón armado de diseño convencional frente a un modelo con disipadores de energía tipo BRB y su incidencia en la relación costo/beneficio
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2023-01)
    Sánchez Arcos, Alex Francisco
    ;
    Peñafiel Valla, Lourdes Gabriela
    For the present research work, a comparative analysis of the seismic behavior between a conventional system and a system with BRB-type energy dissipators was carried out in a 6-story building with a total area of 291.38 m2. The structure is located in the city of Ambato and is classified as essential according to the provisions of the Ecuadorian Construction Standard. The methodology of a nonlinear static analysis (Pushover) was extracted to evaluate the performance of each structural system based on an earthquake with a return period of 475 years, with an exceedance probability of 10 percent in 50 years. For the design of the structural elements, as well as the BRB energy dissipators, both national (NEC 15) and international standards were used: American Society of Civil Engineers (ASCE 7-16, ASCE 41-13), American Concrete Institute (ACI 318-14), American Institute of Steel Construction (AISC 341-16). Obtaining displacement results, derivatives of floors, optimal structural elements, seismic behavior and performance levels of the two structural systems under study.
  • Item type:Ítem,
    Análisis comparativo del desempeño sísmico en edificos de hormigón de mediana altura aplicando riostras de pandeo restringido en la ciudad de Ambato
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-09)
    Zamora Altamirano, Julio Santiago
    ;
    Peñafiel Valla, Lourdes Gabriela
    For this research work we proceeded to perform a comparative analysis of the structural behavior for two types of systems: conventional and with the application of a modern system of seismic dissipation, in an 11-story building consisting of two elevators in an area of 400 square meters; The structure is located in the city of Ambato and was classified in special using the Ecuadorian Construction Standard. The methodology of a Pushover nonlinear static analysis was used to evaluate the performance of each proposed structural system based on a rare earthquake, which is usually the design earthquake with a return period of 475 years with a 10 percent probability of exceedance in 50 years. For the design of the structural elements of the building, as well as for the seismic dissipation system, national and international standards such as the Ecuadorian Construction Standard (NEC 2015), American Society Of Civil Engineers (ASCE 7-16, ACSE 41-13), American Institute Of Steel Constructions (AISC 341-16) were used. Giving us as results the displacements, floor drifts, system energy, behavior and performance levels of the two types of structures with the help of ETABS 2016 software.
  • Item type:Ítem,
    Estudio comparativo del modelo de rotulas plásticas por el método de las fibras y el modelo de tablas del ASCE 41-13, aplicado al análisis no lineal del bloque A de la facultad de Ingeniería Civil y Mecánica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020)
    Reyes Lozada, Carlos Andrés
    ;
    Medina Robalino, Christian David
    The present investigation compiled necessary information such as structural and architectural plans to carry out a performance analysis of the building A of the Facultad de Ingeniería Civil y Mecánica that was built in 1984. Based on publications such as FEMA 356, FEMA 440, ASCE 41-13 and NEC-SEDS 2015, a structural modeling of the building was developed through construction plans with the help of the 2016 ETABS, where linear and non-linear considerations were taken, for the definition of the demand, response spectra and accelerograms properly selected and adjusted according to the demand of the building used as a study center. For each case of nonlinear analysis, two models of plastic hinges are assigned: a model established by ASCE 41-13, and another method known as the fiber hinges. The results of the pushover and response history evaluations are compared with parameters such as: levels of damage, displacements, drifts and the behavior of hinges in the frame sections. It is concluded that the plastic Hinges applied with the method of the tables of ASCE 41-13 have a conservative behavior in relation to the application of plastic hinges by the fiber method, this at the same time this kind of analysis takes longer time of computational analysis, in addition it is determined that in the FICM building there is no correct design of the connections between beams and columns, which leads to a fragile failure, and that plastic hinges occur first in columns and then in beams, a rather critical issue