Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 10 de 25
  • Item type:Ítem,
    Análisis estructural del desempeño sísmico del edificio del Gobierno Autónomo Descentralizado Municipal San Cristóbal de Patate
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03)
    Morales Quispe Jefferson Damian
    ;
    Navarro Peñaherrera Carlos Patricio
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The overall objective of this study is to analyze the seismic performance of the San Cristóbal de Patate Municipal Decentralized Autonomous Government building, constructed in 2008, given Ecuador’s high seismic hazard. To this end, a quantitative methodology with a correlational approach and an applied, descriptive, and non-experimental design was used. The building under study served as both the population and the sample. Data and information for modeling were collected through visual inspections in accordance with the NEC-15 standard, in-situ sclerometric tests, and computational simulations using nonlinear static analysis via the Pushover method with ETABS software. The results reveal that although the concrete in the structure has an average compressive strength of 240 kg/cm², the building as a whole does not meet the minimum requirements of the NEC-15 standard, or the performance parameters set forth by VISION 2000. The simulations demonstrate significant failures such as: extreme torsion, weak node effects, and inelastic drifts exceeding the permitted limit of 2%, causing the building to reach a state of imminent collapse under any type of seismic threat. It is concluded that the building exhibits inadequate overall structural behavior; therefore, the study demonstrates that structural reinforcement using metal jacketing on the columns eliminates torsion, significantly increases structural ductility, and reduces inelastic deflections to levels permitted by code.
  • Item type:Ítem,
    Análisis y diseño comparativo de sistemas de resistencia lateral en edificios de mediana altura para la evaluación sísmica en el sector El Obrero en la ciudad de Ibarra
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01)
    Lloré Cárdenas Pablo Stalyn
    ;
    Cevallos Cabrera Jorge Washington
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This research comparatively evaluates the seismic performance of two lateral force-resisting systems applied to a mid-rise building located in the El Obrero sector of Ibarra, under the provisions of the proposed NEC-26 standard. The study aims to determine the most efficient structural alternative considering the geotechnical conditions and seismic hazard characteristics of the area. The methodology involved the modeling of a six-story building using two structural configurations: a dual system with reinforced concrete shear walls and a concentrically braced frame system using X-bracing (Saint Andrew’s Cross bracing). Due to the instability of the original moment-resisting frame model, which exhibited critical torsional coupling and inelastic story drifts of up to 2.62%, the structure was stabilized through these two lateral force-resisting systems for subsequent analysis and nonlinear performance evaluation. The results showed that both alternatives corrected the stiffness deficiencies and controlled interstory drifts below the allowable limit of 1.50%. However, the inelastic evaluation revealed significant differences in ductility and energy dissipation capacity. The braced system exhibited high initial stiffness associated with a brittle failure mechanism and a premature reduction in its load-carrying capacity. In contrast, the dual system with shear walls demonstrated more ductile behavior, achieving a performance level corresponding to Immediate Occupancy. It is concluded that the dual system constitutes the most suitable alternative for similar buildings in Ibarra, providing improved seismic performance and greater structural resilience.
  • Item type:Ítem,
    Análisis dinámico no lineal del edifico Residencia López del Cantón Ambato, sector Simón Bolívar, en base a la NEC 2024
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-29)
    Parra Yagual Briggite Jessica
    ;
    Cevallos Cabrera Jorge Washington
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This study presents a comprehensive seismic evaluation of the Residencia López building, located in the Simón Bolívar sector of the Ambato canton, with the purpose of determining its structural behavior considering both the NEC-2015-SE-DS criteria and the proposed NEC-2024-SE-DS update. The four-story reinforced concrete building exhibits certain plan and elevation irregularities. To achieve this, the research was organized into three main phases. In the first phase, the current condition of the structure was verified through tests carried out directly on site. Reinforcement scanning was performed on beams and columns, a rebound hammer test was conducted to estimate the concrete strength, and a standard penetration test was used to characterize the soil. This information provided reliable parameters for developing the structural model. In the second phase, a numerical model was created in ETABS 16, incorporating the actual dimensions of the structural elements, the evaluated material properties, and the building’s irregularities. The design spectra of NEC-2015-SE-DS and the proposed NEC-2024-SE-DS were implemented, allowing the execution of the modal spectral analysis and the verification of key parameters such as the fundamental period, modal mass participation, base shear, and allowable drifts. Additionally, three real accelerograms from the 2016 Pedernales earthquake were selected and scaled to the elastic spectra to perform time-history analyses and observe the structure’s dynamic response. The third phase focused on the evaluation of the building. In the Pushover analysis, capacity curves were generated in the four principal directions, showing that the performance point remained within the Operational and Immediate Occupancy levels. This indicates that the building retains a good reserve of strength and stiffness, without approaching severe damage conditions. In the Nonlinear Time-History analysis, results showed that the beams remained almost entirely within the elastic range, and only one column exhibited the onset of plasticity. The drifts obtained for the applied accelerograms stayed below the limits established in NEC-2024- SE-DS, confirming a satisfactory dynamic performance under real seismic events.
  • Item type:Ítem,
    Análisis dinámico no lineal del edificio Residencia Imprenta Galaxia del Cantón Ambato, sector Huachi Loreto, en base a la NEC 2024
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-20)
    Palate Salinas Diego Alexis
    ;
    Cevallos Cabrera Jorge Washington
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This experimental study aimed to perform a nonlinear dynamic analysis of the RESIDENCIA IMPRENTA GALAXIA building, located in the Huachi Loreto sector of the city of Ambato, in order to evaluate its seismic performance by comparing the criteria of NEC2015-SE-DS and the Draft NEC-2024-SE-DS. The building is a five-story reinforced concrete frame, with a basement used as a parking garage, a ground floor intended for an event hall, and three upper stories containing residential apartments. The methodology was organized in three phases. In Phase I, an in-situ evaluation of the materials and soil was carried out. Concrete compressive strengths in columns, beams, slabs and stairs were estimated by means of the rebound hammer test. A reinforcement scanner was used to identify bar diameters, cover depths and reinforcement layout in representative elements. Finally, the Standard Penetration Test (SPT) was performed to characterize the soil profile and determine the soil type used in the definition of the design spectra. In Phase II, the structure was modeled in ETABS 16 using the actual cross-sections, material properties and gravitational loads (live load, self-weight and masonry wall load) obtained previously. Elastic and design spectra were constructed in accordance with NEC-2015-SE-DS and the Draft NEC-2024-SE-DS. A modal response spectrum analysis was then performed, including checks on mass participation, interstory drifts and P-Delta effects, and nonlinear static (pushover) and dynamic time-history load cases were defined, incorporating ground-motion records compatible with the seismic demands specified by NEC-2015-SE-DS and the Draft NEC-2024-SE-DS. In Phase III, the results of the different analyses were examined and compared. The pushover analysis allowed the identification of the formation and distribution of plastic hinges, the performance levels associated with IO, LS and CP states, and the base shear developed by the structure. Linear and nonlinear time-history analyses showed the evolution of displacements, interstory drifts and internal demands under the selected earthquakes, highlighting the differences in seismic demand between NEC-2015-SE-DS and the Draft NEC-2024-SE-DS. Based on these results, conclusions were drawn regarding the seismic behavior of the building and recommendations were proposed to improve its structural safety.
  • Item type:Ítem,
    Análisis del desempeño sísmico del edificio de hormigón armado Hotel Dubai Ambato, Provincia de Tungurahua
    (Ingeniería Civil y Mecánica. Carrera Ingeniería Civil, 2025)
    Chimborazo Sigcha Edison Ariel
    ;
    Medina Robalino Wilson Santiago
    The purpose of this study was to evaluate the seismic performance of the reinforced concrete Hotel Dubai Ambato, located in the Catiglata sector, considering current Ecuadorian regulations. A qualitative and quantitative methodology was used for a comprehensive diagnosis of the existing structure and determination of its seismic performance. The structural analysis using critical linear procedures revealed that the building presented medium seismic vulnerability, primarily associated with structural irregularities and deficiencies in key elements. Maximum lateral drifts of 3.65% and 3.44% were identified in the static and dynamic analysis, exceeding the established limits, and elements that did not meet the load demands, compromising structural safety in severe earthquakes. Furthermore, a nonstatic line analysis (Pushover) verified that the building, in its original state, did not meet the established performance objectives. It was located at critical levels for certain seismic scenarios, reaching the level of collapse in a rare design earthquake, with maximum displacements of up to 27 cm and the formation of plastic hinges on the first three levels. As a solution, a structural reinforcement was proposed, including the incorporation of 25 cm thick shear walls and metal casing of columns with steel angles and plates. After the intervention, the drifts decreased to a maximum of 1.81%, falling within regulatory limits. These interventions also ensured the elements met safety parameters. This resulted in the structure showing reduced maximum displacements and a greater capacity to withstand seismic forces, demonstrating increased structural rigidity and capacity, meeting seismic performance objectives for all established seismic hazard levels
  • Item type:Ítem,
    Análisis de desempeño sísmico del edificio COAC San Martín ubicado en el cantón Tisaleo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil., 2025-02)
    Yugcha Rumiguano, Christian Sebastián
    ;
    Peñafiel Valla, Lourdes Gabriela
    Ecuador is located in the Ring of Fire, so it is subject to stochastic phenomena such as earthquakes, since buildings must be governed according to the current NEC 15 standard to ensure that the design meets earthquake resistance criteria. The purpose of this research work is to determine the seismic performance of the building under study. A qualitative analysis was carried out using the NEC 15 standard, in which the parameters were evaluated according to the characteristics of the structure, obtaining a score of 2.0, demonstrating that it has a medium degree of vulnerability. In the quantitative section, the linear and nonlinear static Pushover analysis of the structure was carried out using engineering software. In the linear analysis, it was determined that the structure in current conditions presents torsion, and that elements such as beams and columns are not designed to withstand the demands. In addition, through non-linear analysis, the capacity curve of the structure was calculated together with the performance levels and it was determined that the construction does not meet the seismic performance objectives according to VISION 2000. Once the evaluation of the structure was completed, three more floors were designed, according to the specifications of the calculation report, and with the requests of these, the structure was reinforced, both locally in the elements such as columns and beams using criteria from the ASCE 41-13 standard, in which the concrete screed method was used for the columns and the steel casing method for the beams, and globally with the implementation of shear walls to control torsion and comply with the vibration period of the structure. Finally, with the implementation of the reinforcement and the addition of 3 more floors to the building, the linear analysis was carried out again, to verify that the calculations and design were in accordance with the NEC 15 standard, checking that the elements had the necessary amounts of steel to generate ductility. After that, the non-linear analysis of the structure was carried out, in which the performance objective was determined, complying with what was established in VISION 2000.
  • Item type:Ítem,
    Determinación del desempeño sísmico del edificio ACT consultores, ubicado en la ciudad de Ambato a través del análisis no lineal push over
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-02)
    Cárdenas López, Fernando Josué
    ;
    Peñafiel Valla, Lourdes Gabriela
    Being located in a highly seismic area, any engineering work is exposed to the possibility of suffering great damage or even collapse under the action of seismic events, that is why the main function of this experimental work is to show the seismic performance of the ACT Consultores building located in the city of Ambato [1]. This work was carried out in three phases; the first one describes the characterization of the architectural and structural building, identifying the materials that were used. Then, the second stage is focused on information processing with the development of the qualitative method, which refers to a quick visual evaluation of the vulnerability of the structure, while the quantitative method refers to the whole process involved in the seismic-resistant design of a building to translate it into the engineering software. Also, the nonlinear analysis was performed by means of a Push Over to evaluate the seismic performance of the building under different levels of seismic hazard without the retaining wall. Finally, the third phase is based on the structural rehabilitation of the building. After reviewing that the building did not comply with period checks, interstory drifts, torsion and the performance point in a "Rare" earthquake was not as expected for basic constructions such as offices. Based on this, we proceeded to place shear walls to correct drifts, torsion, period and performance point so that the building would have better structural behavior.
  • Item type:Ítem,
    Estudio comparativo del diseño sismo resistente de una edificación de estructura metálica de cinco pisos con arriostramientos concéntrico y excéntrico en la Unidad Educativa Tres de Marzo
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Sanabria Espinoza, María Natividad
    ;
    López Arboleda, Alex Gustavo
    The objective of this work was the comparative study of the seismic behavior of buildings with two bracing systems. In Ecuador there are different zones with seismic danger, for this reason, recently improvements have been implemented in the design and construction of steel structure buildings, some of these improvements are the implementation of bracing systems. Although this practice is very useful to improve the seismic behavior of buildings, locally its performance is still being studied. In the analysis proposed in this work, concentric bracing (in X and V) and eccentric bracing (in X and V) were considered for a specific zone. In order to analyze the seismic behavior of the building, the soilstructure conditions were applied with the characteristics of the Chimbo canton that were compiled from a soil study, additionally, a basic building was configured, in which the 4 different types of bracings were applied in order to identify if there is a system that presents a better performance. A Pushover analysis was applied to all configurations to establish which system provides the best results. Finally, it was identified that the inverted V bracings provide the building with greater flexibility without the need to compromise its integrity.
  • Item type:Ítem,
    Evaluación de vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Huachi Grande, Ambato, Ecuador: propuesta de reforzamiento estructural de una edificación representativa
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Santander Paredes, Pablo Andrés
    ;
    Chérrez Gavilanes, Diego Sebastián
    The district of Huachi Grande is part of the rural area of the city of Ambato; however, in recent years it has shown an important economic development not only through agricultural activities, but also through the industrial sector. The objective of this research work was to analyze the seismic vulnerability of metal structure buildings in the district and to evaluate in detail the vulnerability of one of the most representative buildings in order to design a reinforcement proposal. Methods such as rapid visual inspection using the forms established in FEMA P-154, NEC 15 and FUNVISIS were used. It was found that the vulnerability of the buildings in the district was high in the majority of cases. For this reason, an industrial building with a mixed system of hotrolled steel portal frames and cold-rolled steel trusses was selected; the building presented pathologies derived from conceptual errors in the design and assembly of the structure. A detailed vulnerability analysis was performed on the selected building through the linear static and spectral modal method; the limits of floor drifts, basal shear and deflections were checked. It was found that the building does not comply with the load solicitations established by NEC 15; therefore, it was necessary to propose a reinforcement system. The most relevant pathologies were local and lateral buckling of the main and secondary elements. The strengthening strategy included the addition of elements in the columns to form compact elements and also the replacement of secondary elements with more efficient sections. Additional failures were identified such as the inadequate location of tension elements in the trusses and the need to locate San Andres cross members. The reinforcement will allow the building to perform better under service and seismic loads.
  • Item type:Ítem,
    Evaluación de vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Santa Rosa zona 2, Ambato, Ecuador: propuesta de reforzamiento estructural de una edificación representativa
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Carranza Calero, Diego Mauricio
    ;
    Caiza Sánchez, Pablo Enrique
    Seismic vulnerability is a magnitude that allows quantifying structural damage, failure modes and resistant capacity under the action of an earthquake, which is based on the characteristics of the structure. The present work was framed in the vulnerability analysis of metallic structures of the Santa Rosa parish, Zone 2, which has a high level of seismic hazard due to its location and proximity to several geological faults. It was found that most of the metal structure buildings analyzed present a high vulnerability index that indicates that they would suffer great damage in the event of an earthquake. The evaluation criteria used were based on three methodologies: NEC 15, FEMA P-154 and FUNVISIS: perform a more exhaustive analysis, draw vulnerability and seismic risk maps and identify a representative building to perform a detailed analysis and propose a reinforcement proposal, in this building three types of analysis were performed: static, spectral modal and Pushover to identify the critical points of the structure that should be reinforced.