  • Item type:Ítem,
    Caracterización del material de referencia del ensayo de flamabilidad según Norma ISO 3795:1989 para el cumplimiento del requisito 6.6.2 de Norma NTE INEN – ISO/IEC 17025:2018 en el LIM – UTA
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica, 2026-07-05)
    Flores Calapiña Alexander Ismael
    ;
    Herrera Araujo Edwin Alexander
    ;
    Pérez Salinas Cristian Fabian
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica
    This experimental study presents the validation of the flammability testing method for interior materials, in accordance with ISO 3795:1989, with the aim of strengthening the metrological capabilities of the Mechanical Engineering Laboratory at the Technical University of Ambato. To ensure the reliability of the results and promote compliance with the NTE INEN – ISO/IEC 17025:2018 standard, a rigorous quality assurance process was implemented. The methodology involved conducting physical tests, which were successfully carried out at the university laboratory's facilities. The methodology was based on physical testing, which was successfully conducted at the university laboratory facilities. To ensure the traceability and accuracy of the method, the scope of the study focused exclusively on the use of Reference Materials (RM) and Certified Reference Materials (CRM). The experimental tests were conducted on samples of twill fabric and flame-retardant gabardine. Following the completion of the tests, validation of the method required an external evaluation, for which a formal collaboration was established with a laboratory in Argentina that provides proficiency testing in accordance with the NTE INEN – ISO/IEC 17043:2010 standard. The research is currently in the data analysis and final report drafting phase. The statistical analysis compares the internal results obtained at the local laboratory with the metrological parameters provided by the Argentine laboratory. This intercomparison with the MRs and MRCs is essential for evaluating the accuracy and reproducibility of the local method. The results aim to confirm the laboratory's technical competence and ensure the delivery of reliable test reports.
  • Item type:Ítem,
    Implementación de los requisitos técnicos establecidos por la norma técnica ecuatoriana NTE INEN-ISO-IEC 17025- 2018 para ensayos de inflamabilidad en materiales textiles de acuerdo con la norma ASTM d6413 para los Laboratorios de la Carrera de Mecánica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2023-09)
    Yunda Buñay, Fernando Efraín
    ;
    Castro Miniguano, Christian Byron
    This technical project presents the need for the implementation of the technical requirements established in the Ecuadorian Technical Standard NTE INEN-ISO/IEC 17025-2018 because the Mechanical Research Laboratory for Vertical Flammability Tests on Textile Materials requires the documentation established in this standard to establish itself as a more reliable laboratory. For the preparation of documents, records and instructions, a thorough study of the NTE INEN-ISO/IEC 17025-2018 Standard was carried out, complying with the requirements established therein. In addition, vertical flammability tests were developed for 5 textile materials (Nomex, Antifluids, Denim, Die-cut Polyester and Cotton) in accordance with the parameters established in the ASTM D6413 Standard, where vertical flame resistance was measured by evaluating post-flame and postincandescence times. One of the main objectives of the project is the validation of the measurement method, which was carried out by means of the data obtained from the vertical flammability tests and the use of specialized software, obtaining a result of less than 30 percent, considered acceptable according to the criteria established by the AIAG. At the end of the project, both the documentation and the results of the method validation will be delivered to the Mechanical Research Laboratory LIM - UTA, where they will be used for the benefit of the Technical University of Ambato.
  • Item type:Ítem,
    Metodología de ensayo de laboratorio de la Facultad de Ingeniería Civil y Mecánica para la medición de ruido ambiental y laboral
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2022-09)
    Ortiz Peñafiel, Luis Alberto
    ;
    Pilapanta Lasso, Darwin Bladimir
    ;
    Castro Miniguano, Christian Byron
    In this technical project, the methodology for Environmental and Occupational noise testing was developed and validated, the development and validation corresponds to a verification of the test method of Annex 5 of Ministerial Agreement 097-A, NTE INEN-ISO 1996-1 and 2 -2014 for Environmental noise; Art 55 of Executive Decree 2393, NTE INEN-ISO 9612-2014 for occupational noise, which allows evaluating the specific noise with impulsive characteristics and with energy content at low frequencies and the Level of exposure at work respectively. For this purpose, real measurements were performed. For the assurance and validity of the method two levels were used with a class I sound level meter, it was configured in the required parameters for both Environmental and Occupational noise: A-weighted sound pressure level (slow and impulsive), Cweighted sound pressure level (slow), total noise was measured using the Leq 15s methodology with the fixed noise sources on and residual noise with the fixed noise sources off and for Occupational Noise the task-based strategy was used. For both methods, the overall performance of the methodology was evaluated and accepted in a working range of 20 dB to 140 dB, since it was demonstrated that the acceptance criteria met the established validation parameters: CVr and CVI precision measurement less than or equal to 5 percent, veracity in uncertainty less than or equal to 10 percent of the minimum measurement taken by the sound level meter and dynamic uncertainty.