  • Item type:Ítem,
    Análisis estructural del desempeño sísmico del edificio del Gobierno Autónomo Descentralizado Municipal San Cristóbal de Patate
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03)
    Morales Quispe Jefferson Damian
    ;
    Navarro Peñaherrera Carlos Patricio
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The overall objective of this study is to analyze the seismic performance of the San Cristóbal de Patate Municipal Decentralized Autonomous Government building, constructed in 2008, given Ecuador’s high seismic hazard. To this end, a quantitative methodology with a correlational approach and an applied, descriptive, and non-experimental design was used. The building under study served as both the population and the sample. Data and information for modeling were collected through visual inspections in accordance with the NEC-15 standard, in-situ sclerometric tests, and computational simulations using nonlinear static analysis via the Pushover method with ETABS software. The results reveal that although the concrete in the structure has an average compressive strength of 240 kg/cm², the building as a whole does not meet the minimum requirements of the NEC-15 standard, or the performance parameters set forth by VISION 2000. The simulations demonstrate significant failures such as: extreme torsion, weak node effects, and inelastic drifts exceeding the permitted limit of 2%, causing the building to reach a state of imminent collapse under any type of seismic threat. It is concluded that the building exhibits inadequate overall structural behavior; therefore, the study demonstrates that structural reinforcement using metal jacketing on the columns eliminates torsion, significantly increases structural ductility, and reduces inelastic deflections to levels permitted by code.
  • Item type:Ítem,
    Análisis de vulnerabilidad sísmica y reforzamiento estructural de la unidad nueva del Hospital Básico El Puyo, ubicado en la provincia de Pastaza, Ecuador
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Cáceres Vargas, Andrea Carolina
    ;
    Caiza Sánchez, Pablo Enrique
    Seismic vulnerability in essential structures has been a subject of little analysis despite the importance that a building of this type entails, therefore, this research covers the constructive reality of the new unit of the Basic Hospital El Puyo, a structure built with regulations In force, however, the lack of technical criteria of the professionals who designed it significantly influenced the construction, generating cracking problems. During the development of this research, it was necessary to assess the vulnerability of this structure through quick visual inspections and the application of forms with the NEC 2015, FEMA P-154 and FUNVISIS methodologies. Then, non-destructive tests of concrete and soil tests were carried out in order to verify that the design plans have been respected. Subsequently, a mathematical model of this structure composed of two blocks was analyzed using structural design software, where, through a linear static analysis, it turned out that it presented torsion in one of its blocks, which is why a reinforcement was proposed. structural by means of steel stiffening diagonals in certain side frames. On the other hand, the current seismic performance of blocks 1 and 2 was considered, through a non-linear static analysis, obtaining as a result, that they do not meet the performance level for the rare design earthquake, since, the point The performance of these blocks is outside the capacity curve, its resistance being insufficient to meet the seismic requirements; Thus, under this criterion, the pushover was executed with the two reinforced structures, verifying that there is a good seismic performance. Finally, the soil-structure interaction analysis was carried out, verifying that the hospital unit presents permitted differential settlements.
  • Item type:Ítem,
    Evaluación del desempeño sísmico del edificio de la Oscus mediante comparación del análisis estático no lineal (Pushover), análisis estático modal (Pushover Multimodal) y dinámico no-lineal (Historia de Respuesta).
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civil, 2019)
    Galarza Altamirano, Daniela Alexandra
    ;
    Medina Robalino, Christian David
    For this investigation, in first instance the structural plans of the building "Oscus" were obtained, in addition the resistance to compression of concrete was obtained by means of sclerometric tests, the current regulations in the year of construction was the Ecuadorian Code of Construction (CEC-77 in base of ACI 318-71). Based on this information, the building was modeled in three dimensions in Etabs 2016 software, considering non-linearity parameters. For the definition of the demand, the response spectrum and appropriately selected accelerograms were used, adjusted and scaled according to the NEC-SE-DS for an earthquake with probability of exceeding 50 years of 10% . Necessary information was gathered from publications such as: FEMA-440, FEMA- 356 and ATC-40 in addition to scientific articles. Non-linear seismic analysis procedures were performed, such as: Time History (NL-RHA), Pushover (NSP) and Multimodal Pushover (MPA), by defining their respective modal cases, once the analysis was finished, the results were processed. , which were compared in terms of displacements, drifts, capacity and level of damage, where it was possible to detect some deficiencies, limitations, advantages and disadvantages of the analyzes. Of the alternative seismic analysis methodologies studied, the one that produces the smallest errors is the MPA analysis, for this reason, it is concluded that it is the most appropriate. The three analyzes determined that the structure reaches its maximum displacement before fulfilling its objective displacement which means a great inconsistency in its seismic performance demonstrating its high vulnerability and risk of possible collapse.
  • Item type:Ítem,
    Análisis cuantitativo y cualitativo del grado de vulnerabilidad sísmica de la Facultad de Ciencias Administrativas de la Universidad Técnica de Ambato, Campus Huachi.
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civil, 2019)
    Montalvo Quinteros, Gabriel Alejandro
    ;
    Cevallos Cabrera, Jorge Washington
    In the present research work, the degree of seismic vulnerability of the administrative building of the faculty of Administrative Sciences of the Technical University of Ambato, Campus Huachi, was determined by means of two methodologies such as Qualitative and Quantitative. For the first methodology formats raised were used by both local and international standards, the results of which were opposed because by FEMA 154 format is described the structure as highly vulnerable, and using the formats set by the NEC 2015 and the National Secretary Risk Management structure did not present any seismic vulnerability, for this analysis took into account primarily irregularities in plan and elevation, soil type, the year it was built and materials. For the second approach the point of performance of the structure was determined by a nonlinear analysis, in the same way, the four damage thresholds (MILD, MODERATE, EXTENSIVE, COMPLETE) suggested by RISK EU and HAZUS was calculated, which they served of base to carry out an analysis of fragility to the structure thus presenting a high degree of probability that the structure will enter into extensive and complete damage, which means that it presents a high seismic vulnerability.