Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
3 resultados
Resultados de la búsqueda
Item type:Ítem, Diseño y construcción de la estructura de una máquina de pruebas para conexiones metálicas viga-columna(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2023-09) ;Shigüi Caiminagua, Dennis LeonelPeña Jordán, Francisco AgustínIn recent years, it has become evident that steel buildings have been constructed without properly qualified and tested connections because there is no ordinance requiring engineers to perform inspections or tests of the different types of connections prior to construction. For the elaboration of the project, bibliographic research was carried out focused on similar testing machines, as well as on the processes of prequalification and qualification of beam-column connections. Subsequently, the design of the most effective alternative was carried out, following the parameters and recommendations provided by the current standards and with the help of specialized simulation software, the behavior of the design was verified. Likewise, the drawings of each of the parts were made, as well as the respective assembly and construction drawings of the project. Finally, the structure was built, the hydraulic system was assembled, and its functionality was verified with the help of a test sample. At the end of this project, the aim is to contribute to the construction industry with an efficient tool for the qualification of beam-column connections and thus guarantee a higher safety factor in metallic constructions.Item type:Ítem, Análisis comparativo del comportamiento sísmico de una estructura de hormigón armado de diseño convencional frente a un modelo con disipadores de energía tipo BRB y su incidencia en la relación costo/beneficio(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2023-01) ;Sánchez Arcos, Alex FranciscoPeñafiel Valla, Lourdes GabrielaFor the present research work, a comparative analysis of the seismic behavior between a conventional system and a system with BRB-type energy dissipators was carried out in a 6-story building with a total area of 291.38 m2. The structure is located in the city of Ambato and is classified as essential according to the provisions of the Ecuadorian Construction Standard. The methodology of a nonlinear static analysis (Pushover) was extracted to evaluate the performance of each structural system based on an earthquake with a return period of 475 years, with an exceedance probability of 10 percent in 50 years. For the design of the structural elements, as well as the BRB energy dissipators, both national (NEC 15) and international standards were used: American Society of Civil Engineers (ASCE 7-16, ASCE 41-13), American Concrete Institute (ACI 318-14), American Institute of Steel Construction (AISC 341-16). Obtaining displacement results, derivatives of floors, optimal structural elements, seismic behavior and performance levels of the two structural systems under study.Item type:Ítem, Análisis comparativo del desempeño sísmico en edificos de hormigón de mediana altura aplicando riostras de pandeo restringido en la ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-09) ;Zamora Altamirano, Julio SantiagoPeñafiel Valla, Lourdes GabrielaFor this research work we proceeded to perform a comparative analysis of the structural behavior for two types of systems: conventional and with the application of a modern system of seismic dissipation, in an 11-story building consisting of two elevators in an area of 400 square meters; The structure is located in the city of Ambato and was classified in special using the Ecuadorian Construction Standard. The methodology of a Pushover nonlinear static analysis was used to evaluate the performance of each proposed structural system based on a rare earthquake, which is usually the design earthquake with a return period of 475 years with a 10 percent probability of exceedance in 50 years. For the design of the structural elements of the building, as well as for the seismic dissipation system, national and international standards such as the Ecuadorian Construction Standard (NEC 2015), American Society Of Civil Engineers (ASCE 7-16, ACSE 41-13), American Institute Of Steel Constructions (AISC 341-16) were used. Giving us as results the displacements, floor drifts, system energy, behavior and performance levels of the two types of structures with the help of ETABS 2016 software.
