Diseño de conexiones entre perfiles conformados en frío de sección UV en acero ASTM A36, utilizados para la construcción de torres de telecomunicaciones
| dc.contributor.advisor | Peña Jordán Francisco Agustín | |
| dc.contributor.author | Candilejo Simbaña Adrián Alexander | |
| dc.contributor.author | Martinez Chuncha Alex Daniel | |
| dc.contributor.editor | Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica | |
| dc.date.accessioned | 2026-07-05T09:11:13Z | |
| dc.date.issued | 2026-07-05 | |
| dc.description | La presente investigación se enfocó en el diseño y evaluación de una conexión empernada entre perfiles conformados en frío de sección UV, fabricados en acero ASTM A36, destinados a torres de telecomunicaciones. El estudio surgió ante la necesidad de mejorar el comportamiento de conexiones metálicas livianas sometidas a cargas axiales, ya que los mecanismos de falla local pueden afectar la estabilidad del sistema estructural. Para ello, se propuso una configuración con perfiles UV de 6 mm de espesor, placas de unión de 8 mm y pernos galvanizados A325. La metodología combinó ensayos experimentales de tracción y compresión en probetas ensambladas, determinando la respuesta mecánica, carga y desplazamientos máximos, y los modos de falla asociados. Paralelamente, se desarrollaron modelos mediante el método de elementos finitos para representar el comportamiento bajo cargas axiales. La comparación entre resultados experimentales y numéricos se realizó utilizando el promedio de sus cargas máximas alcanzadas. En tracción se obtuvo una carga promedio experimental de 276,20 kN, mientras el modelo de elementos finitos alcanzó 254,22 kN, con 7,96 % de error porcentual. El modo de falla estuvo asociado a daños locales en los agujeros. En compresión se obtuvo 258,36 kN de carga máxima promedio experimental, mientras el modelo de elementos finitos alcanzó 238,64 kN, con un error porcentual de 7,63 %. El modo de falla estuvo asociado al pandeo local de las almas de los perfiles y de la placa de conexión. Los modelos reprodujeron el modo de falla y la capacidad resistente de la conexión propuesta. | |
| dc.description.abstract | This research focused on the design and evaluation of a bolted connection between cold-formed UV-section profiles made of ASTM A36 steel, intended for telecommunication tower structures. The study arose from the need to improve the behavior of lightweight steel connections subjected to axial loads, since local failure mechanisms can affect the stability of the structural system. For this purpose, a connection configuration was proposed using 6 mm thick UV profiles, 8 mm connection plates, and galvanized A325 bolts. The methodology combined experimental tensile and compression tests on assembled specimens to determine the mechanical response, maximum load and displacement, and associated failure modes. In parallel, finite element models were developed to represent the behavior of the connection under axial loading. The comparison between experimental and numerical results was carried out using the average maximum load as the main evaluation parameter. In tension, an average experimental load of 276,20 kN was obtained, while the finite element model reached 254,22 kN, with a percentage error of 7,96 %. The failure mode was associated with local damage around the holes. In compression, an average experimental maximum load of 258,36 kN was obtained, while the finite element model reached 238,64 kN, with a percentage error of 7,63 %. The failure mode was associated with local buckling of the profile webs and the connection plate. The models reproduced the failure mode and load-bearing capacity of the proposed connection. | |
| dc.identifier.citation | Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica | |
| dc.identifier.uri | https://repositorio.uta.edu.ec/handle/123456789/47152 | |
| dc.language.iso | es | |
| dc.publisher | Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica | |
| dc.subject | ACERO CONFORMADO EN FRÍO | |
| dc.subject | PERFIL UV | |
| dc.subject | CONEXIÓN EMPERNADA | |
| dc.subject | ACERO ASTM A36 | |
| dc.subject | MÉTODO DE ELEMENTOS FINITOS | |
| dc.subject | TORRES DE TELECOMUNICACIONES | |
| dc.title | Diseño de conexiones entre perfiles conformados en frío de sección UV en acero ASTM A36, utilizados para la construcción de torres de telecomunicaciones | |
| dc.type | bachelorThesis |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Tesis I.M 939 Candilejo Simbaña Adrián Alexander-Martinez Chuncha Alex Daniel.pdf
- Tamaño:
- 8,02 MB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 1,71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: