Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
4 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis del efecto de la adición de fibras de cabuya en la resistencia a compresión del hormigón f´c= 210 kg/cm2(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03) ;Mayorga Escola Cesar Andres ;Portilla Yandun Favio PaulUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThis experimental research evaluates the mechanical feasibility of incorporating raw cabuya fibers into a structural concrete matrix with a specified compressive strength of f'c = 210 kg/cm², conducted at the laboratories of the Universidad Técnica de Ambato. The methodology comprised two phases. In the first, aggregates from Mina Cristóbal were physically and mechanically characterized per NTE INEN standards 696, 856, 857, 858, and 860, yielding a fineness modulus of 3.00, nominal maximum size of ½", and abrasion loss of 21.32%. Type IP cement specific gravity was determined at 2.991 g/cm³ (NTE INEN 156). The control mix was proportioned using the ACI 211.1 method, establishing a water-to-cement ratio of 0.56. In the second phase, cylindrical specimens were cast with fiber mass additions of 0%, 0.5%, 1.0%, 1.5%, 2.0%, and 2.5%, tested under uniaxial compression at 7, 14, 21, and 28 days per NTE INEN 1578. The control concrete achieved 250.17 kg/cm² at 28 days, exceeding the theoretical requirement by 19.1%. Fiber incorporation induced progressive strength reductions: 122.70 kg/cm² at 0.5% and 14.24 kg/cm² at 2.5%, representing decreases of 50.9% and 94.3% respectively. No modified specimen reached the required structural threshold. It is concluded that untreated cabuya fiber severely compromises concrete mechanical performance, precluding its direct structural application. Alkaline surface treatments and dosages below 0.5% are recommended for future research.Item type:Ítem, Análisis comparativo de la resistencia a compresión del hormigón estructural y el hormigón permeable reforzado con fibras de nylon(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-06-30) ;Vallejo Guerrero Melanie Valeria ;Medina Robalino Wilson SantiagoUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThis research aimed to comparatively analyze the compressive strength of conventional concrete and permeable concrete reinforced with nylon fibers, evaluating the influence of fiber incorporation on the mechanical behavior and physical properties of the material. The study arose from the need to develop construction materials that contribute to urban sustainability and efficient stormwater management. In this context, permeable concrete represents an attractive alternative due to its ability to reduce surface runoff and promote water infiltration; however, its main limitation lies in its relatively low mechanical strength. For the development of this research, the constituent materials were characterized through physical tests conducted in accordance with ASTM and NTE INEN standards. Subsequently, conventional concrete mixtures were designed using the ACI 211 method, while permeable concrete mixtures were designed following the ACI 522-23 method, incorporating nylon fibers at proportions of 0.00%, 0.05%, 0.10%, 0.15%, and 0.20%. Cylindrical specimens were produced and tested for compressive strength at 7, 14, 21, and 28 days. Additionally, complementary properties such as density, porosity, and permeability were evaluated. The results showed that increasing the fiber content led to a progressive reduction in density and compressive strength, accompanied by an increase in porosity and permeability. The mixture containing 0.05% nylon fibers exhibited the best mechanical performance, representing the most balanced alternative between strength and hydraulic functionality.Item type:Ítem, Análisis teórico-experimental de la resistencia a la compresión del hormigón y su influencia en el módulo de elasticidad estático en el cantón Santo Domingo de los Colorados, provincia de Santo Domingo de los Tsáchilas(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-09) ;Chacón Santos, Víctor SteveGuevara Robalino, Jorge JavierThis research work was carried out by taking samples of stone materials from the "Brisas del Toachi" and "Copeto" mines using INEN 695 standards, then a sample reduction was made according to INEN 2566, continuing with the investigation of some physical mechanical characteristics indicated in INEN 872 in order to make a dosage for a structural concrete and determine the actual density of cement using INEN 156. The mix design was made for each mine with its respective dosage using the method of optimum densities for concrete compressive strengths of 210 and 240 kilograms over square centimeters. Once the dosages were obtained for each mine, concrete specimens were made for their respective curing using INEN 3124 standard; fresh concrete tests were carried out, such as: sampling INEN 1763; density, air content and yield INEN 1579, settlement INEN 1578; hardened concrete tests were carried out to determine the compressive strength at 3, 7 and 28 days INEN 1573. With this we have access to information that allows us to interpret and graph these values for a better understanding and analysis of them. Finally, the experimental MEE is determined by using the ASTM C469 standard and with this, the use of values for the factors exposed in the ACI 318-14 standard and its correct adaptation according to the use of the materials of the mines studied is proposed.Item type:Ítem, Análisis del módulo de elasticidad estático del hormigón estructural en base a su resistencia a la compresión, fabricado con materiales de las minas Trópico de Capricornio y Santa Isabel, ubicadas en el sector El Barranco cantón Mera en la provincia de Pastaza(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020-09) ;Flores Medina, Pablo XavierMedina Robalino, Wilson SantiagoThe present experimental work began with the sampling of the aggregates of the two mines, following the guidelines of INEN 695 and their subsequent reduction to test size according to INEN 2566; Therefore, arid characterization studies were developed to decree their suitability to be used in structural concrete identified in INEN 872; in addition to achieving the actual density of INEN 156 cement. Based on the above, the design of mixtures with their respective dosage was developed for the compression resistances of the 21 and 28 Mpa concrete, with the help of the optimal density method. A single dosage was used because in test trials if they achieved the expected resistances; a total of 84 specimens were then tested according to INEN 3124;with their respective fresh trials such as: INEN 1763 sampling, density, air content and INEN 1579 performance, INEN 1578 settlement; as well as in hardened state obtaining the resistances to INEN 1573 compression at ages 7, 14, 21 and 27 days, making it possible to graph the curves age vs resistance to compression and stress vs deformation of structural concrete. Finally, the static elasticity modulus of concrete was determined according to ASTM C469 and accordingly the constants are proposed for local adaptation depending on the origin of material equation used that is presented in the present experimental work.
