Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 3 de 3
  • Item type:Ítem,
    Análisis técnico económico del coeficiente de reducción de respuesta estructural con aplicación y comparación en sistemas aporticados de estructuras metálicas
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Jácome Guanopatín, Ángel Patricio
    ;
    Cañizares Ortega, Freddy Fernando
    In this degree work, the analysis and calculation of the seismic reduction factor for a structure with special moment frames (PEM or SMF) composed of four different mathematical models where the seismic reduction factor changes with values of R=8, 6, 4, 5 and 3. 5 and 3; performing the dynamic linear structural analysis of the four models, each structure changes according to the demand required by the seismic forces, determining that the lower the value of R the larger sections are required in the structure, in spite of the above, the fundamental vibration period of the structures was maintained for R= 8, 6 and 4. 5, while for the factor R=3 the period is slightly reduced resulting in a stiffer structure, as the seismic response factor is reduced, more robust sections are required to provide more weight to the structure to meet the demand. An economic analysis was performed with the sections obtained, which shows that the lower the R value, the structure requires a higher weight and therefore influences a higher cost, so the structure with the lowest cost is the structure with an R=8. Additionally, a pseudo-static non-linear analysis was determined to determine the structural performance of each of the four models using the ATC-40 and FEMA- 440 methods, highlighting that the models maintain the same architectural and geometric configuration but with different sections in certain elements that required a higher geometry as the R value decreases, after obtaining the results of the static non-linear analysis, the performance point was determined using the ASCE 41-17 and FEMA 440 (2005) methodology, resulting in the R=8, 6, 4. 5 and 3 for 475 years has a performance level in X and Y of immediate occupancy. For the determination of the structural response factor, the methodology proposed by Dr. Aguiar 2006 was followed, which is similar to that of ATC-19 (1995), where the ductility, resistance and redundancy factor is determined, data that are collected from the performance point obtained for the elastic design spectrum with a return period of 475 years, the structural response factors R obtained establish that the average range is between 6 and 7.5, on the other hand the structure that presents greater capacity and performance is the one that was designed with R=4. 5 so having extremely rigid sections does not guarantee stability and ductility in a structure, finally a high level of performance (immediate occupation) and seismic energy dissipation capacity is established in the structure designed with a R=6 where its value is similar and slightly lower than 4.5, so it is concluded that for a structure of special steel composite moment frames a design with a structural response factor equal to 6 should be sought.
  • Item type:Ítem,
    Desempeño de estructura metálica mediante análisis dinámico con acelerogramas ajustados con espectro medio condicional (CMS)
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09)
    Pérez Galarza, Christian Danilo
    ;
    Chérrez Gavilanes, Diego Sebastián
    The present investigation is carried out in Huachi Loreto in Ambato city, starting as a first point, to identify the geological faults near this study site that can contribute to generate a seismic event that affects the structures in the area. Using empirical formulas, the value of the shear wave velocity was obtained based on calculated values, specific to the site, such as the length of the fault, source - study distance, focal depth, expected moment magnitude, and values of the number of blows of the SPT test performed in situ. This shear wave velocity allows determining the type of soil existing in the area according to the ranges established by the Ecuadorian Construction Standard (NEC 2015). Subsequently, an attenuation model was chosen (Montalva) that allows to determine, by applying certain equations called GMPEs (ground motion prediction equations), a possible behavior of the soil based on complementary data to those already mentioned specific to the site such as distance and hypocentral depth. From the GMPE graph and the uniform hazard spectrum (UHS) and applying certain equations determined in the Bakker model, the conditional mean spectrum (CMS) was obtained. The use of this spectrum allowed a comparison of the behavior of a metallic structure proposed in this study, with respect to the elastic spectrum imposed by the NEC. This comparison was made on the basis of the results provided by the nonlinear dynamic analysis (time-history), through which the performance of the same structure subjected to scaled seismic events was determined with respect to the CMS and the NEC spectrum. It was obtained as a result that the seismic demand produced by the NEC spectrum is greater than that produced by the CMS, since the pseudospectral accelerations have a great difference between these spectra, which is why the maximum displacements and drifts are reduced by approximately 65 percent by applying the CMS in the present investigation.
  • Item type:Ítem,
    Estudio comparativo del modelo de rotulas plásticas por el método de las fibras y el modelo de tablas del ASCE 41-13, aplicado al análisis no lineal del bloque A de la facultad de Ingeniería Civil y Mecánica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020)
    Reyes Lozada, Carlos Andrés
    ;
    Medina Robalino, Christian David
    The present investigation compiled necessary information such as structural and architectural plans to carry out a performance analysis of the building A of the Facultad de Ingeniería Civil y Mecánica that was built in 1984. Based on publications such as FEMA 356, FEMA 440, ASCE 41-13 and NEC-SEDS 2015, a structural modeling of the building was developed through construction plans with the help of the 2016 ETABS, where linear and non-linear considerations were taken, for the definition of the demand, response spectra and accelerograms properly selected and adjusted according to the demand of the building used as a study center. For each case of nonlinear analysis, two models of plastic hinges are assigned: a model established by ASCE 41-13, and another method known as the fiber hinges. The results of the pushover and response history evaluations are compared with parameters such as: levels of damage, displacements, drifts and the behavior of hinges in the frame sections. It is concluded that the plastic Hinges applied with the method of the tables of ASCE 41-13 have a conservative behavior in relation to the application of plastic hinges by the fiber method, this at the same time this kind of analysis takes longer time of computational analysis, in addition it is determined that in the FICM building there is no correct design of the connections between beams and columns, which leads to a fragile failure, and that plastic hinges occur first in columns and then in beams, a rather critical issue