Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
2 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis estructural del desempeño sísmico del edificio de Ingeniería Mecánica de la Facultad de Ingeniería Civil y Mecánica mediante la medición de vibraciones(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-03) ;Pimbo Palate, Freddy PolivioSuquillo Ronquillo, Betzabeth JesseniaOne of the methodologies used is the rapid visual inspection and evaluation through formats and matrices of the International Standard FEMA 154, and those proposed by the Ecuadorian Regulation NEC 2015, with the objective of recognizing and classifying the structure by its vulnerability seismic, with the two proposals the average degree of vulnerability was determined, for the analysis the most relevant parameters were: irregularities in plan and elevation, the structural system and the type of soil. With all the information collected, the linear analysis and the non-linear static analysis were carried out to verify the modal parameters, the behavior of the building and of each structural element. With the results obtained from the linear analysis, it was determined that the vibration period and the floor drifts do not comply with what is established in the Ecuadorian Regulations, it also presents a torsional behavior in its vibration modes and from the non-linear static analysis it was observed that the building it has a deficient capacity for different levels of seismic threats, presenting a high degree of vulnerability. With the results of the two methodologies used, a proposal to reinforce the building was made, one was proposed at a global level with the placement of shear walls and another at a local level with the steel cladding for the beams, considerably improving their behavior and complying with the checks established in the regulations in force. Finally, a comparison was made of the periods obtained by the different analyzes with the period of vibration obtained by empirical formulas that were based on environmental vibrations, to relate them to the degree of vulnerability of the structure.Item type:Ítem, Estudio comparativo del modelo de rotulas plásticas por el método de las fibras y el modelo de tablas del ASCE 41-13, aplicado al análisis no lineal del bloque A de la facultad de Ingeniería Civil y Mecánica(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020) ;Reyes Lozada, Carlos AndrésMedina Robalino, Christian DavidThe present investigation compiled necessary information such as structural and architectural plans to carry out a performance analysis of the building A of the Facultad de Ingeniería Civil y Mecánica that was built in 1984. Based on publications such as FEMA 356, FEMA 440, ASCE 41-13 and NEC-SEDS 2015, a structural modeling of the building was developed through construction plans with the help of the 2016 ETABS, where linear and non-linear considerations were taken, for the definition of the demand, response spectra and accelerograms properly selected and adjusted according to the demand of the building used as a study center. For each case of nonlinear analysis, two models of plastic hinges are assigned: a model established by ASCE 41-13, and another method known as the fiber hinges. The results of the pushover and response history evaluations are compared with parameters such as: levels of damage, displacements, drifts and the behavior of hinges in the frame sections. It is concluded that the plastic Hinges applied with the method of the tables of ASCE 41-13 have a conservative behavior in relation to the application of plastic hinges by the fiber method, this at the same time this kind of analysis takes longer time of computational analysis, in addition it is determined that in the FICM building there is no correct design of the connections between beams and columns, which leads to a fragile failure, and that plastic hinges occur first in columns and then in beams, a rather critical issue
