    Diseño y construcción de un prototipo para recuperación de calor residual en el calderín pirotubular de 2 BHP del Laboratorio de Energía de la Carrera de Ingeniería Mecánica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2021-01)
    Pérez Rojas, Wilman Omar
    ;
    Cabrera Anda, Santiago Paúl
    This technical project has the function of recovering the residual heat from the gases or fumes that are expelled directly into the environment by the boiler chimney, which will also contribute to a large extent to solve a deficit of equipment in the energy laboratory, and will help so that students can carry out practices of the theory learned. The compilation of information was carried out through reliable research sources such as magazines, books, scientific publications, and duly verified websites that provide relevant data to the project. First, the metallic heat recovery unit was chosen, then the design and simulation in software was carried out to verify its operation and thus can be validated and used, later it was passed to the manufacturing process, and finally it was completed with physical tests of operation. The simulation was carried out with the existing data of the temperature with which the combustion gases exit through the boiler chimney and with the support of the properties of the fluids found in the software library, also the data of the cold fluid that will be air at room temperature, when performing the simulation, the temperature increase of the cold fluid was verified by means of the circulation carried out during the heat recovery process. Finally, the results were obtained and it was observed that the lower the speed, the greater the increase in temperature we have of the cold fluid, to mention when the temperature is 20 degrees Celsius at a speed of 5 meters per second, it reaches a temperature of 34.2 degrees Celsius, all we can see the data with different speeds in the simulation results.
  • Item type:Ítem,
    Análisis térmico para evaluar eficiencia en un calderín Pirotubular de 2 BHP del laboratorio de la Carrera de Ingeniería Mecánica
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2019)
    Sánchez Mendoza, Alejandro Sebastián
    ;
    Cabrera Anda, Santiago Paúl
    Was evaluated efficiency by applying techniques of thermography in a 2BHP boiler of the career of mechanical engineering of the Technical University of Ambato. The data were taken using technological equipment: thermal camera, thermocouple, thermometer digital, bimetal thermometer, combustion gas analyzer and volumetric meter of GLP. Was obtained thermograms, temperature of gases, temperature of steam pipes, composition of gases, volumetric composition of products and consumption of GLP.Analysis was performed using the indirect method, was calculated losses caused by heat transfer (convection and radiation) 17.4%, combustion 5.17%, unburnt 8.7% and not quantified losses 10%. Was determined an efficiency of 59%. Finally, was proposed four proposals to improve the functioning of the boiler and was executed maintenance cleaning of tubes and burner due to time a financial resource, obtaining a fuel-saving of 0.12 kg/h and the reduction in the temperature of the combustion gases.