Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 2 de 2
  • Item type:Ítem,
    Comportamiento frente al fuego del bahareque de viviendas patrimoniales en la sierra del Ecuador
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2025-02)
    Guaraca Freire, Joel Adrian
    ;
    Paredes Beltrán, Bolívar Eduardo
    Bahareque is a traditional construction technique widely used in Ecuador due to its low cost and sustainable approach. However, the houses built with this method present a high vulnerability to fire due to the nature of its main materials, reed, straw and mud. Despite their adaptability, these materials have not been sufficiently studied in terms of their reaction to fire, which represents a significant risk for the structures and their inhabitants. This research is focused on analyzing the behavior of wattle and daub in the face of fire, in order to provide relevant information to optimize its safety without compromising its cultural and heritage value. For this purpose, several tests were carried out in accordance with NTE INEN ISO 11925-2 and EN 13501-1 classification, to evaluate its flammability and establish its classification within the European standard. In addition to the reaction to fire tests, complementary tests were carried out, such as granulometric analysis, Atterberg limits, compressive strength and evaluation of the material's anisotropy. In total, 10 samples were tested for compression with dimensions of 300x100x100 mm, and 12 samples were tested for fire test (six edge tested and six surface tested) with dimensions of 250x90x50 mm. The variability in the arrangement of the reed in the samples allowed evaluating the influence of the orientation of the material on fire propagation. The tests showed that the initial fire propagation speed in the wattle and daub was 0.41 mm/s, reducing to 0.29 mm/s and 0.2 mm/s after 300 seconds, according to NTE INEN ISO 11925-2 tests. Thermal conductivity analyses confirmed its moderate insulation, which slows the spread of fire. With a compressive strength of 9.17 kg/sq cm, the wattle-and-daub is suitable for non-load-bearing walls. Finally, its Euroclass B classification according to EN 13501-1 indicates that the material can withstand a small flame for a long time without significant flame spread, which supports its viability as a sustainable building material.
  • Item type:Ítem,
    Caracterización de la curva de consumo de la red de agua potable de la zona urbana del cantón Santiago de Píllaro provincia de Tungurahua
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2024-02)
    Jácome Eugenio, María Solange
    ;
    Castro Solórzano, Fidel Alberto
    The daily consumption of potable water allows estimating the per capita consumption of a specific area by evaluating and identifying various situations, providing utility in subsequent activities and studies in the field of hydraulic engineering, such as enhancing the distribution system for the population. The behavior of daily potable water consumption in the respective area was studied. The process commenced with information gathering, involving 148 meters studied through simple random sampling. Subsequently, data collection spanned 45 days of measurements and 7 consecutive days of pressure readings. Regarding hourly consumption determination, a camera was installed in 7 residential houses on the meters during the same period. After tabulating the data, necessary calculations were performed, defining an average daily consumption for the area of 0.76 cubic meters per day. Maximum and minimum consumptions were also identified. Patterns of consumption displayed heterogeneous values to the mean, designating Sunday as the day of highest consumption. As for per capita consumption, it was found to be below the recommended allocation by CPE INEN 005-9-1, indicating an overestimation. Additionally, representative maps of the area were generated through GIS software based on pressure values and per capita consumptions per meter.