Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
24 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis estructural del desempeño sísmico del edificio del Gobierno Autónomo Descentralizado Municipal San Cristóbal de Patate(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03) ;Morales Quispe Jefferson Damian ;Navarro Peñaherrera Carlos PatricioUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThe overall objective of this study is to analyze the seismic performance of the San Cristóbal de Patate Municipal Decentralized Autonomous Government building, constructed in 2008, given Ecuador’s high seismic hazard. To this end, a quantitative methodology with a correlational approach and an applied, descriptive, and non-experimental design was used. The building under study served as both the population and the sample. Data and information for modeling were collected through visual inspections in accordance with the NEC-15 standard, in-situ sclerometric tests, and computational simulations using nonlinear static analysis via the Pushover method with ETABS software. The results reveal that although the concrete in the structure has an average compressive strength of 240 kg/cm², the building as a whole does not meet the minimum requirements of the NEC-15 standard, or the performance parameters set forth by VISION 2000. The simulations demonstrate significant failures such as: extreme torsion, weak node effects, and inelastic drifts exceeding the permitted limit of 2%, causing the building to reach a state of imminent collapse under any type of seismic threat. It is concluded that the building exhibits inadequate overall structural behavior; therefore, the study demonstrates that structural reinforcement using metal jacketing on the columns eliminates torsion, significantly increases structural ductility, and reduces inelastic deflections to levels permitted by code.Item type:Ítem, Evaluación de la vulnerabilidad sísmicas de edificios de concreto armado con irregularidades en planta y altura mediante simulación en Etabs(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-27) ;Núñez Álvarez David Rafael ;Medina Robalino Wilson SantiagoUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilEste trabajo experimental tuvo como objetivo evaluar la vulnerabilidad sísmica de estructuras de hormigón armado, analizando comparativamente la influencia de las irregularidades en planta y en elevación. La investigación nace ante la necesidad de conocer hasta qué punto influyen estas irregularidades dentro del desempeño sísmico. En cuanto a la metodología se adoptó un enfoque cuantitativo, el cual se lo llevó a cabo mediante la simulación numérica en el software ETABS, donde se aplicó los criterios de la NEC 15 para el análisis lineal, así mismo para los análisis no lineales, se tuvo en cuenta los criterios establecidos en la norma ASCE41-13, con la finalidad de obtener los puntos de desempeño de cada estructura. El trabajo abarcó los análisis lineales y no lineales de 3 edificaciones: Estructura 1 (irregularidad en planta), Estructura 2 (irregularidad en elevación) y Estructura 3 (irregularidad en planta y elevación) Los resultados del análisis lineal pusieron en evidencia que la irregularidad en planta fue la más crítica. Las estructuras 1 (irregular en planta) y la estructura 3 (irregular en elevación y planta), excedieron el límite de las derivas inelásticas permitidas por la NEC 15 (2%), alcanzado valores de 2.39% y 2.55% respectivamente en el sentido Y. Por el contrario, la estructura 2 (irregular en elevación), sus derivas se mantuvieron dentro del rango permitido siendo de 1.95%. Para estabilizar a las estructuras 1 y 3, se implementó muros de corte de hormigón armado con un espesor de 25cm, lo que permitió reducir en gran medida las derivas a valores permitidos de 1.69% y 1.82% respectivamente. Finalmente, los puntos de desempeño obtenidos del análisis Pushover demostraron que todas las edificaciones alcanzan el nivel de desempeño esperado “Seguridad de vida” (LS) ante el sismo de diseño (raro). Se evidenció que la estructura 2 sin muros de corte (irregular en elevación) presentó un desplazamiento mayor (22cm), en comparación a la estructura 1 (irregular en planta) y estructura 3 (irregular en planta y elevación) que presentaron desplazamientos menores de 15 cm y 19 cm respectivamente. Se concluye que las irregularidades en planta generan una vulnerabilidad sísmica superior a la irregularidad de altura en edificios de mediana altura, certificando que el uso de muros de corte como una mejora estructural es eficaz para controlar la torsión y garantizar el desempeño sísmico esperadoItem type:Ítem, Propuesta de reducción de riesgo de daño por sismos en elementos no estructurales y de contenidos de la Facultad de Ciencia e Ingeniería en Alimentos de la UTA.(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil., 2025-02) ;Moposita Ñacato, Jonathan EduardoRamírez Cabrera, Wladimir JoséThe research responds to the growing vulnerability of these infrastructures in the face of the high seismic activity characteristic of Ecuador, especially in the region (Ambato). The main purpose of this technical project is to evaluate, classify and mitigate the seismic risks associated with the non-structural elements and contents of the aforementioned building. The methodology used in the project was of a mixed nature, combining qualitative and quantitative approaches to address the specific objectives defined. The qualitative analysis consisted of visual inspections, the completion of technical sheets using the FEMA E 74 Standard that explains the procedure where the following matrices were classified: inventory, seismic risk, liability, grouping of components studied to classify and mitigate the non-structural elements according to their risk, which is broken down into humanitarian, loss of material and functionality that contain details of engineering criteria, prescriptive and non-engineering requirements. The quantitative analysis involved structural modelling in specialised software that provided accelerations and mathematical calculations for the design of the anchorages in two groups that required engineering criteria such as: mechanical and electrical components, plumbing, furniture, shelving, bookcases, filing cabinets and other components. The next stage involved the tabulation and evaluation of technical data in accordance with FEMA E-74 and NEC-15 standards. Finally, a reference budget was drawn up to reduce inventory costs in a seismic event. As a result, the project demonstrates the importance of addressing seismic risks from a holistic perspective combining technical analysis, design of specific solutions and economic planning. Its implementation will ensure not only the safety of the university community, but also the operational continuity of academic and scientific activities after seismic events. In addition, the work contributes to the strengthening of a culture of prevention and resilience in seismically active areas.Item type:Ítem, Estudio del peligro sísmico determinista para las estructuras de la ciudad de Ambato sector Huachi Chico ubicado entre las calles los Shyris, av. Atahualpa, Víctor Hugo, av. los Atis, av. de los Chasquis, av. Pichincha y la av. Rumiñahui(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil., 2025-02) ;Gavilanez Soria, Wilson GabrielRamírez Cabrera, Wladimir JoséEcuador is located within a zone of high seismic activity called the Pacific Ring of Fire, due to the collision of the Nazca and South American tectonic plates, which is why understanding seismicity is necessary for any calculation or plan to mitigate its effects and is essential for the development of building codes. Therefore, this experimental work focused on the delimitation of a sector of the city of Ambato, in Huachi Chico. Then, deterministic acceleration spectra were generated using Ground Motion Prediction Equations (GMPEs) for the Tectonic Regime (Crustal and Subduction Regime), mainly obtaining the following seismic characteristics: SPT bearing capacity, soil characterization and typology, nearby geological faults affecting the study area, seismic moment magnitude Mw, and shear wave velocity Vs. This allowed for the generation of deterministic spectra and obtaining the envelope, to then make a comparison with the spectrum obtained by the NEC-2015 standard. When verifying the obtained data, it was found that the deterministic spectrum obtains the highest maximum acceleration values of Sa= 1.319 (g) in a period of 0.4 (s), while the NEC-2015's maximum acceleration value reached is Sa= 1.190 (g) in periods from 0.2 to 0.6s. As a result, 3 structures built in the sector were selected and the structural effects that could affect them were compared. It was concluded that in the analysis of drifts, loads, shears, and moments of the structures to which the deterministic spectrum was applied, greater results were obtained. Therefore, this is a call to take into account that structures in the sector should be analyzed applying deterministic spectra, as this will improve the structural analysis of buildings.Item type:Ítem, Evaluación de la vulnerabilidad sísmica de edificaciones de estructuras metálicas de la parroquia La Península, Ambato, Ecuador: Propuesta de reforzamiento estructural de una edificación representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2024) ;Pérez Castro, Víctor HugoChérrez Gavilanes, Diego SebastiánThe parish of La Peninsula in the city of Ambato is located in an area of high seismic hazard in Ecuador. This parameter, together with the vulnerability of the buildings and the level of exposure, represents the level of risk that could occur in the face of these events. Seismic vulnerability is a magnitude that allows quantifying structural damage, failure modes and resistance capacity under the action of an earthquake, based on the characteristics of the building such as the type of structural system, irregularities in the floor plan, elevation, frequency of maintenance, application of regulations, construction codes and other parameters that are controllable, to provide an overview of the degree of vulnerability and seismic risk index of the buildings. The first step was to identify the buildings in which the main component was the metal structure, and from there, with the help of the forms proposed in the FEMA P-154, NEC 15 and FUNVISIS standards, it was finally possible to establish the degree of vulnerability of these buildings. For the interpretation of the results, the NEC 15 and AISC 360 criteria were used because the buildings found in the area were of traditional moment frames. A representative building in the area was selected to evaluate in detail the seismic vulnerability, in this case a linear static and spectral modal analysis was performed,Item type:Ítem, Estudio del comportamiento sísmico de la interacción suelo-cimentación en una estructura metálica representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-10) ;Morales Zúñiga, Humberto RamiroRamírez Cabrera, Wladimir JoséEcuador is located in an area of high seismic hazard, mountainous terrain, slopes of low, medium and high slopes in the Sierra region mainly, the high housing deficit and without considering the danger of founding the structures in this type of soil, the human being makes disorderly settlements and without any planning and control by government entities, This is why it is necessary to carry out a comprehensive technical analysis to determine the favorable response of the building to a dynamic event in a sloping terrain. The factors involved in the dynamic soil-structure interaction were analyzed, such as accelerations, velocities, displacements, the relationship between them and the variations in the fundamental period of the structure when considering the flexibility of the foundation soil; For which through the use of springs and dampers (impedance functions) that represent the dynamic response of the IDSE system based on the Barkan model and the NEC-15, the increase of the flexibility in the foundation base of the soil-structure interaction model, with respect to the rigid base model in a type D soil, was determined by means of dynamic and experimental simulation. As a consequence of the present research work, a notorious change in the behavior of the foundation of the structure was obtained, which was subjected to the load solicitations initially proposed and related to the traditional rigid base model. The results of the present study can be used to improve design and construction techniques, in addition to providing relevant information to professionals in the engineering field on the soilfoundation interaction of structures. In order to extend the analysis of the aforementioned conditions, an analysis of the soil-structure behavior can be included in future research.Item type:Ítem, Evaluación de vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Izamba zona 1, Ambato, Ecuador: Propuesta de reforzamiento estructural de una edificación representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03) ;Toapanta Tixilema, Hugo FabiánLópez Velástegui, Jorge EnriqueThe city of Ambato has a high seismic hazard. For all the buildings that have been built and will be built are directly exposed to a high seismic risk. Therefore, it is necessary to perform a seismic vulnerability analysis of the structures and specifically those which have been built in areas with geological faults or that have been implemented in places where earthquakes have previously occurred and caused human or material losses. The Izamba parish is one of the areas with high seismic danger due to the previously mentioned factors. For this reason, it was necessary to evaluate the state in which the metal structure buildings were found in terms of the structural system they were built with, and the irregularities that were part of each building. The methodology carried out for the analysis was mixed, the FEMA P-154, NEC 15 and FUNVISIS rapid visual inspection forms used qualitative criteria to determine the degree of vulnerability of the buildings, while the detailed analysis with linear methods was quantitative. For the interpretation of the results, the NEC 15 and AISC 360 criteria were used because the buildings found in the area were of ordinary moment frames. A representative building in the area was selected to evaluate in detail the seismic vulnerability. In this case, a linear static and spectral modal analysis was performed. Subsequently, a structural reinforcement system was proposed and its efficiency was verified by means of the static and modal spectral analysis and the seismic-resistant design criteria established by the current regulations in force. Finally, computational tools were used for the structural calculation and verification of the proposed design.Item type:Ítem, Evaluación de vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Santa Rosa zona 1, Ambato, Ecuador: propuesta de reforzamiento estructural de una edificación representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03) ;Suatunce Toaquiza, Víctor JonnyChérrez Gavilanes, Diego SebastiánSeismic vulnerability analysis is a relevant parameter within the context in which the city of Ambato is located. Due to the seismic hazard, buildings are exposed to a constant threat, especially those located in areas with geological faults, sites where earthquakes have previously occurred and generated collapses and human losses. The Santa Rosa parish is one of the areas with a high seismic hazard due to the previously mentioned factors. For this reason, it was necessary to evaluate the condition of the metal structure buildings in terms of the structural system with which they were built and the irregularities in elevation and in plan that were part of each building. The methodology carried out for the analysis was mixed, the FEMA P-154, NEC 15 and FUNVISIS rapid visual inspection forms used qualitative criteria to determine the degree of vulnerability of the buildings, while the detailed analysis with linear methods was quantitative. For the interpretation of the results, the NEC 15 and AISC 360 criteria were used because the buildings found in the area were of ordinary moment frames. A representative building in the area was selected to evaluate in detail the seismic vulnerability, in this case a linear static and spectral modal analysis was performed. Subsequently, a structural reinforcement system was proposed and its efficiency was verified by means of the static and modal spectral analysis and the seismic-resistant design criteria established by the current regulations in force. Finally, computational tools were used for the structural calculation and verification of the proposed design.Item type:Ítem, Evaluación de la vulnerabilidad sísmica de edificaciones de estructuras metálicas en la parroquia Izamba (Zona 3), Ambato, Ecuador. Propuesta de reforzamiento estructural de una edificación representativa(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03) ;Vargas Aráuz, Ángela VerónicaLópez Velástegui, Jorge EnriqueThis research work shows the application of the rapid visual inspection methodology according to FEMA P-154, with which it is possible to identify, inventory and examine the possible seismic risks of the buildings evaluated and with this information decide if a detailed structural evaluation is necessary. The seismic vulnerability according to FEMA P-154 is expressed in terms of the probability of collapse of the structure, with this information you can manage contingency plans before and after earthquakes and inform the owner of the building the status and possibility of structural reinforcement. After carrying out the evaluation of the selected buildings, a representative structure was determined located in the Izamba parish of the city of Ambato, which was chosen for its level of importance and based on the results of the previous evaluation. With the data obtained from the rapid visual inspection and the documentation obtained from the representative building, a linear static analysis was carried out, with the application of the Ecuadorian construction standard, to determine the current behavior of the structure according to its efforts, displacements, and maximum permitted drifts. The structural analysis determined that the building presents great flexibility and fails in some members such as beams and columns. As a solution to the problem detected, structural reinforcement was chosen with steel diagonals to increase the rigidity of the structure and incorporate additional structural members that support seismic actions. The research was completed by performing the nonlinear static analysis known as Pushover of the reinforced building, from this analysis the capacity curve is obtained and the probable performance of the structure before the design earthquake can be verified.Item type:Ítem, Análisis de vulnerabilidad sísmica y reforzamiento estructural del edificio Colineal, ubicado en la parroquia Atocha-Ficoa, cantón Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03) ;Romero Guamanquispe, Jorge RobertoNúñez Aldas, Galo WilfridoIn this degree work, as an initial part, a seismic vulnerability analysis of the metal structure buildings in the Atocha-Ficoa parish is carried out through quick visual inspections using the forms established by the Ecuadorian Construction Standard NEC-2015, FUNVISIS as well as by the Federal Emergency Management Agency of the United States FEMA P-154, since through this study it was determined that the houses in this parish present a medium-high vulnerability, Thus, the most representative building was selected, the Colineal company building, which presents technical-constructive observations of structural order such as fissures, cracks, detachment of plaster on walls and floors, which has caused a premature deterioration of the infrastructure. For this reason, an analysis was carried out by means of mathematical models through the ETABS computer program, where a linear analysis was performed to verify structural parameters such as drifts, displacements, and vibration periods. Subsequently, a non-linear static analysis (Pushover) was performed to determine the capacity of the structure and its performance level in the presence of a seismic event, to finally determine, based on the performance obtained, a structural reinforcement system by means of concentric diagonals, which will provide greater stability, ductility and resistance to the building and through this constructive alternative improve its seismic performance level and adequately meet the technical criteria for life safety.
