Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
5 resultados
Resultados de la búsqueda
Item type:Ítem, Diseño de estructuras de monopolos de telecomunicaciones utilizando la norma ANSI/TIA 222 H(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica, 2026-01-21) ;Gavilanes Punina Joel Alejandro ;Peña Jordán Francisco AgustínUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería MecánicaThe technical project presented herein focuses on the development of the structural design of a telecommunications monopole, carried out in accordance with the requirements established by the ANSI/TIA-222-H standard. The objective of this study is to ensure a safe and efficient structural performance under wind, seismic, and gravitational actions generated by the equipment and accessories installed on the structure. The research is based on an integrated methodology that combines normative criteria with finite element software analysis and a detailed verification of structural joints, resulting in a design that is consistent with both real operating conditions and constructive requirements. The characterization of loads was performed by calculating the wind dynamic pressure derived from the application of the corresponding normative coefficients, while the seismic action was determined according to the Ecuadorian Construction Code (NEC). The structural analysis was carried out using SAP2000, modeling the monopole as a system composed of four dodecagonal sections with progressive variations in diameters and thicknesses, a criterion that enhances stiffness distribution and provides an efficient geometric transition along the height of the structure. The results indicate concentrations of stresses and bending moments at the base, consistent with the expected behavior of a slender cantilevered element. The design of welded and bolted joints was conducted using the educational version of IDEA StatiCa, which enables the evaluation of the resistance of bolts, flanges, and heat-affected zones, considering structural steels ASTM A36 and A572 Grade 50, as well as FCAW welding procedures according to AWS D1.1. This ensures adequate structural integrity and continuity in the transfer of forces between sections. Additionally, the project includes a constructive proposal that addresses assembly procedures, module alignment, and installation criteria to ensure safe field execution. The analysis confirms that the proposed design meets the resistance, stability, and serviceability requirements established by current standards. Furthermore, the selected geometry and joint configurations demonstrate appropriate behavior under the governing load conditions. It is recommended to implement rigorous quality control measures during fabrication and assembly to ensure proper execution and structural performance throughout the service life of the system.Item type:Ítem, Diseño de una Cimentación tipo Ringwall para soportar tanques de almacenamiento de Asfalto, en base a la norma API-650(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16) ;Coba Gavilanez Kevin Israel ;Navarro Peñaherrera Carlos PatricioUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThe primary objective of this research is to design a ringwall foundation for vertical storage tanks for petroleum products, specifically asphalt, following the guidelines established in API 650. To this end, an initial literature and regulatory review was conducted, based on API 650, NEC-15, ASCE 7-22, and ACI 318-19 as technical standards. Additionally, theses, specialized books, websites, and online resources were consulted to further the understanding of the system and its practical application. The appendices present the manual calculations for the foundation, which determine contact pressures, stresses in the ring, minimum reinforcement requirements, and stability verification. It is important to note that the geotechnical parameters used in the analysis are imposed values due to the lack of field tests. Therefore, typical and conservative data for Ecuadorian Amazonian soil were adopted to ensure an efficient and safe design. Subsequently, the Results chapter presents the computational analysis performed using specialized software. The foundation was modeled, and loads were assigned, including the tank's self-weight, fluid load, active and passive soil pressure, permanent surcharge, seismic load, and others. The service load combinations proposed by ASCE 7-22 were then input, amplifying the loads with amplification coefficients to achieve a more conservative structural design. Therefore, after activating the software, the internal stresses, deformations, and the required steel reinforcement area for the foundation were obtained, ensuring the system meets the strength and serviceability criteria established by the consulted standards. The results demonstrate that the proposed foundation is structurally viable and complies with regulatory requirements, constituting a suitable alternative for implementation in flat-bottomed vertical storage tanks.Item type:Ítem, Análisis estructural del desempeño sísmico del edificio de Ingeniería Mecánica de la Facultad de Ingeniería Civil y Mecánica mediante la medición de vibraciones(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-03) ;Pimbo Palate, Freddy PolivioSuquillo Ronquillo, Betzabeth JesseniaOne of the methodologies used is the rapid visual inspection and evaluation through formats and matrices of the International Standard FEMA 154, and those proposed by the Ecuadorian Regulation NEC 2015, with the objective of recognizing and classifying the structure by its vulnerability seismic, with the two proposals the average degree of vulnerability was determined, for the analysis the most relevant parameters were: irregularities in plan and elevation, the structural system and the type of soil. With all the information collected, the linear analysis and the non-linear static analysis were carried out to verify the modal parameters, the behavior of the building and of each structural element. With the results obtained from the linear analysis, it was determined that the vibration period and the floor drifts do not comply with what is established in the Ecuadorian Regulations, it also presents a torsional behavior in its vibration modes and from the non-linear static analysis it was observed that the building it has a deficient capacity for different levels of seismic threats, presenting a high degree of vulnerability. With the results of the two methodologies used, a proposal to reinforce the building was made, one was proposed at a global level with the placement of shear walls and another at a local level with the steel cladding for the beams, considerably improving their behavior and complying with the checks established in the regulations in force. Finally, a comparison was made of the periods obtained by the different analyzes with the period of vibration obtained by empirical formulas that were based on environmental vibrations, to relate them to the degree of vulnerability of the structure.Item type:Ítem, Influencia de la acción sísmica vertical en edificaciones de hormigón armado ubicados en la ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020-09) ;Maldonado Vallejo, Gabriel AlexanderSuquillo Ronquillo, Betzabeth JesseniaThis research analyzed the influence of the vertical earthquake component on regular concrete structures, the analysis group consists of 2 reinforced concrete structures, one of twelve and other of four floors, these were analyzed in soils C, D and E obtaining a total of 18 models, all these in the city of Ambato. The predesign of the structural elements was carried out and it was modeled using the Etabs software applying the non-linear design according to the NEC 15 to verify that the different models comply with the checks of our Ecuadorian standard. After that, a comparison was made in which the results of three analyses were presented, the first without considering the effects of the vertical component, second considering the recommendation of the NEC SE DS 15 which indicates that the vertical acceleration is two-thirds of the horizontal acceleration and the last using real vertical acceleration using the Ambato microzoning study and ASCE 7-16. It was concluded that the vertical component of the earthquake has no great influence on displacements, shears and floor drifts otherwise it is directly affecting structural elements such as columns and beams duplicating the axial load on some columns and increasing the deflections in cantilever beams. It was also determined that the ratio of two-thirds underestimates the vertical effects in cities near seismic failures.Item type:Ítem, Estudio comparativo del modelo de rotulas plásticas por el método de las fibras y el modelo de tablas del ASCE 41-13, aplicado al análisis no lineal del bloque A de la facultad de Ingeniería Civil y Mecánica(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020) ;Reyes Lozada, Carlos AndrésMedina Robalino, Christian DavidThe present investigation compiled necessary information such as structural and architectural plans to carry out a performance analysis of the building A of the Facultad de Ingeniería Civil y Mecánica that was built in 1984. Based on publications such as FEMA 356, FEMA 440, ASCE 41-13 and NEC-SEDS 2015, a structural modeling of the building was developed through construction plans with the help of the 2016 ETABS, where linear and non-linear considerations were taken, for the definition of the demand, response spectra and accelerograms properly selected and adjusted according to the demand of the building used as a study center. For each case of nonlinear analysis, two models of plastic hinges are assigned: a model established by ASCE 41-13, and another method known as the fiber hinges. The results of the pushover and response history evaluations are compared with parameters such as: levels of damage, displacements, drifts and the behavior of hinges in the frame sections. It is concluded that the plastic Hinges applied with the method of the tables of ASCE 41-13 have a conservative behavior in relation to the application of plastic hinges by the fiber method, this at the same time this kind of analysis takes longer time of computational analysis, in addition it is determined that in the FICM building there is no correct design of the connections between beams and columns, which leads to a fragile failure, and that plastic hinges occur first in columns and then in beams, a rather critical issue