Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 2 de 2
  • Item type:Ítem,
    Análisis estructural del desempeño sísmico del edificio del Gobierno Autónomo Descentralizado Municipal San Cristóbal de Patate
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-03)
    Morales Quispe Jefferson Damian
    ;
    Navarro Peñaherrera Carlos Patricio
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The overall objective of this study is to analyze the seismic performance of the San Cristóbal de Patate Municipal Decentralized Autonomous Government building, constructed in 2008, given Ecuador’s high seismic hazard. To this end, a quantitative methodology with a correlational approach and an applied, descriptive, and non-experimental design was used. The building under study served as both the population and the sample. Data and information for modeling were collected through visual inspections in accordance with the NEC-15 standard, in-situ sclerometric tests, and computational simulations using nonlinear static analysis via the Pushover method with ETABS software. The results reveal that although the concrete in the structure has an average compressive strength of 240 kg/cm², the building as a whole does not meet the minimum requirements of the NEC-15 standard, or the performance parameters set forth by VISION 2000. The simulations demonstrate significant failures such as: extreme torsion, weak node effects, and inelastic drifts exceeding the permitted limit of 2%, causing the building to reach a state of imminent collapse under any type of seismic threat. It is concluded that the building exhibits inadequate overall structural behavior; therefore, the study demonstrates that structural reinforcement using metal jacketing on the columns eliminates torsion, significantly increases structural ductility, and reduces inelastic deflections to levels permitted by code.
  • Item type:Ítem,
    Análisis de vulnerabilidad sísmica y reforzamiento estructural de la unidad nueva del Hospital Básico El Puyo, ubicado en la provincia de Pastaza, Ecuador
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2023-03)
    Cáceres Vargas, Andrea Carolina
    ;
    Caiza Sánchez, Pablo Enrique
    Seismic vulnerability in essential structures has been a subject of little analysis despite the importance that a building of this type entails, therefore, this research covers the constructive reality of the new unit of the Basic Hospital El Puyo, a structure built with regulations In force, however, the lack of technical criteria of the professionals who designed it significantly influenced the construction, generating cracking problems. During the development of this research, it was necessary to assess the vulnerability of this structure through quick visual inspections and the application of forms with the NEC 2015, FEMA P-154 and FUNVISIS methodologies. Then, non-destructive tests of concrete and soil tests were carried out in order to verify that the design plans have been respected. Subsequently, a mathematical model of this structure composed of two blocks was analyzed using structural design software, where, through a linear static analysis, it turned out that it presented torsion in one of its blocks, which is why a reinforcement was proposed. structural by means of steel stiffening diagonals in certain side frames. On the other hand, the current seismic performance of blocks 1 and 2 was considered, through a non-linear static analysis, obtaining as a result, that they do not meet the performance level for the rare design earthquake, since, the point The performance of these blocks is outside the capacity curve, its resistance being insufficient to meet the seismic requirements; Thus, under this criterion, the pushover was executed with the two reinforced structures, verifying that there is a good seismic performance. Finally, the soil-structure interaction analysis was carried out, verifying that the hospital unit presents permitted differential settlements.