Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
1 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis dinámico no lineal del edificio Residencia Vargas del cantón Ambato, sector la Merced, en base a la NEC 2024(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16) ;Balladares Aldas Oscar Steven ;Cevallos Cabrera Jorge WashingtonUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilEcuador, being located in an active seismic zone, faces a high risk of seismic events that can seriously affect the safety of its buildings. Therefore, it is essential to evaluate the structural performance of buildings to prevent material and human losses in the event of earthquakes. This experimental work focused on an irregular five-story building, with a mezzanine and overhangs on the front facades, located in the parish of La Merced, Ambato canton. The objective was to perform a nonlinear dynamic analysis to study the seismic behavior of the structure under various seismic conditions. To establish the essential data of the structure, three test were developed: the sclerometer, which allowed the concrete resistance to be established, the standard penetration test which determined the type of soil of the building, and finally, the scanner test, which allowed the distribution of the reinforcing steel in structural elements such as beams and columns to be visualized. The analysis included three complementary methods: a spectral modal analysis, a pushover analysis, and finally, a time-history analysis. The spectral modal analysis allowed for obtaining the vibration frequencies of the structure under seismic loads, while the pushover analysis evaluated the capacity curve. Finally, the time-history analysis simulated the behavior of the building under a real earthquake, using elastic design spectra and accelerograms to evaluate its performance under different seismic intensities. The results showed that the dimensions of the beams and columns of the building do not meet the requirements established by the Ecuadorian Construction Standard (NEC), which compromises their capacity for resistance to seismic events of great magnitude. In view of this situation, it was recommended to increase the size of the sections of the structural elements to improve the rigidity and seismic resistance of the building, which would allow a greater energy absorption capacity and reduce the risk of structural failures in a seismic event. This study highlights the importance of performing advanced seismic analysis to ensure the structural safety of buildings and protect both people and material assets in areas of high seismic activity such as Ecuador.
