Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 3 de 3
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos de las parroquias: Cotundo, San Pablo de Ushpayucu, y Archidona cabecera cantonal, provincia de Napo utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01)
    Rosero Toalombo Christofer Adrian
    ;
    Pérez Maldonado Ruth Lorena
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This study addressed the thermal susceptibility of Amazonian soils in the parishes of Cotundo, San Pablo de Ushpayacu, and Archidona La Cabecera Cantonal in the Napo province, driven by the increasing risk of wildfires. The main objective was to quantify the physicomechanical, hydraulic, and bearing capacity changes of the material when subjected to a controlled temperature of 750 °C. All geotechnical procedures were carried out based on international standards such as ASTM and AASHTO, contrasting the properties of the materials in their natural state against their post-thermal treatment state. The results indicated an irreversible geomechanical degradation. The CBR residual bearing capacity support a critical collapse, with San Pablo de Ushpayacu being the most affected parish, registering a variation of 34.00%. The loss of support was due to clay deactivation and the decrease in the plasticity index, where Cotundo exhibited the lowest resistance, with an absolute decrease of 29.53% in its plasticity index. Hydraulic conductivity showed an increase across the three samples, with Cotundo marking an 82.46% increase in permeability due to the elimination of the soil's organic fraction. The time-monitored tests determined that the soil is non-combustible. It was concluded that fire significantly affects soil stability, rendering them mechanically unstable but highly permeable.
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego del suelo de las comunidades de Santa Clara, San Jorge y Rey de Oriente, cantón Santa Clara, provincia de Pastaza empleados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-06-30)
    Durán Muñoz Melanie Dayanara
    ;
    Gallardo Donoso Lidia Jhoanna
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The research characterizes the physical and mechanical behavior of soils from Santa Clara, San Jorge, and Rey de Oriente, Santa Clara canton, Pastaza, after exposure to 750 °C. The study addresses the limited information available on how fire alters the geotechnical properties of Amazonian soils. Samples were analyzed in their natural condition and after thermal treatment through grain size distribution, Atterberg limits, specific gravity, permeability, modified Proctor, CBR, and flammability tests, following ASTM, AASHTO, and NTE INEN standards. Results showed differentiated alterations depending on each soil. Fine content increased in all cases; Rey de Oriente recorded the highest increment, from 5.55% to 11.88%. Atterberg limits decreased in all three soils; Rey de Oriente showed the most pronounced reduction, with its plasticity index dropping 62.82%. Specific gravity increased only in Santa Clara, while the other two decreased due to intergranular expansion. Rey de Oriente's permeability decreased 56.76%, shifting from low to very low permeability category. All three soils increased their maximum dry density and reduced their optimum moisture content. CBR maintained or slightly improved bearing capacity, preserving the subgrade classification. No soil exhibited spontaneous ignition, although all showed visible physical changes such as color alteration and particle disaggregation. It is concluded that fire significantly modifies plasticity and permeability without compromising bearing capacity, providing a technical foundation for geotechnical risk management in Amazonian areas with a history of forest fires
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos provenientes de las parroquias Pano, Muyuna y Puerto Napo de la provincia de Napo utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16)
    Rivadeneyra Loor Melanie Gabriela
    ;
    Pérez Maldonado Ruth Lorena
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The present research addressed the problem of the thermal susceptibility of soils used in civil works within the Amazon Region, specifically in the Pano, Muyuna, and Puerto Napo parishes of Napo province, facing the growing threat of forest fires. The main objective was to quantify the alteration of the material's physico-mechanical properties and bearing capacity when subjected to a controlled temperature of 750ºC. To achieve this, a comparative experimental methodology was implemented, structured around standardized laboratory tests, including grain size analysis, Atterberg limits, permeability, Modified Proctor (Type B), and the California Bearing Ratio (CBR). All geotechnical procedures were rigorously executed following international ASTM and AASHTO standards, in addition to national NTE INEN standards, which guaranteed the traceability, precision, and replicability of the results by contrasting the soil in its natural state versus the post-thermal treatment state. The results demonstrated an irreversible and significant alteration in the material's properties. A systematic reduction in the structural capacity was verified, with the Pano sample experiencing the greatest loss of support, showing a decrease in CBR of 32.86%, confirming that heat exposure negatively affects its subgrade classification. This loss correlated with a critical reduction in cohesion and plasticity, being more pronounced in Puerto Napo with a decrease in the Plasticity Index of 62.78%. In contrast, thermal stress generated beneficial secondary effects on the hydraulic properties, recording an increase in the permeability coefficient (k) in all three samples, showing increases of up to 96.44% in the Muyuna parish sample, attributed to the combustion of organic matter and micro-fissuring of the matrix. The synthesis of the findings concluded that fire exposure compromises the soil's structural stability, transforming it into a more fragile material, but one with better drainage capacity, which is fundamental for risk management in the region's engineering.