Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
6 resultados
Resultados de la búsqueda
Item type:Ítem, Análisis comparativo de una estructura habitacional con diagonales excéntricas y una estructura sin diagonales excéntricas, ante una solicitación sísmica(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-09) ;Salazar Gamboa, Alvaro NapoleónFrías Torres, Alex XavierThe main objective of this research work was the comparative analysis of a housing structure under seismic stress, taking as a reference point the urban area of Ambato, capital city of the province of Tungurahua, where the building under study is located. A specialized software was used for the modeling and design of the structure, as well as the guidelines of the Ecuadorian construction standard NEC-SE-DS 2015 and ANSI/AISC 360 and 341, respectively. The results obtained were satisfactory with respect to drifts and deflections, according to the configuration in columns, beams and diagonals it was not necessary to redesign the sections of the structural elements. Regarding the analysis, it should be noted that both the structure without eccentric braced frame and the structure with eccentric braced frame obtained an adequate behavior, with drifts of less than 2 percent that comply with the stipulations of the standard, but a notable difference was evidenced in the sections of both columns and beams, obtaining a 45.88 percent reduction in the weight of the structural elements. In the structure with eccentric braced frame, the drifts were maintained within the established limits for this typology according to the NEC with the inclusion of some diagonals, which helped to improve the behavior, reducing considerably the different sections of the structural elements, thus lightening the structure, achieving a balance and avoiding torsional effects in the floor plan, as well as allowing compliance with the maximum floor drifts that limit seismic damage. It was concluded that the structure with eccentric braced frame presents a better lateral resistance to the action of an earthquake due to the addition of the diagonals, which are responsible for redistributing the lateral forces within the building, lightening the structure and considerably reducing the weight of the elements and the consumption of materials.Item type:Ítem, Análisis y diseño de un edificio con aisladores sísmicos utilizando el programa ETABS(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2022-07) ;Chimbo Chacha, Washington JoelRamírez Cabrera, Wladimir JoséFor the development of this project, the difference in the dynamic behavior of fixed and isolated structures was identified. the difference in dynamic behavior of structures with: fixed base and with isolation, for this purpose, the objective was to analyze and compare the seismic behavior between them. This research was evaluated on the design of base isolators, observing the behavior of the following parameters: drifts, mass participation, vibration period, accelerations and shear. Through the pre-design, we proceeded with the modeling of the two buildings by using appropriate software for the analysis, performing the linear modal spectral analysis for the fixed base building by using the NEC - 15 design spectrum; for the system with isolation, the nonlinear time-history analysis was performed, considering the maximum probable earthquake, for which appropriate accelerograms were used and adjusted according to the area and type of soil. It is concluded that the implementation of seismic isolators to a fixed base structure, provides a better structural behavior during an earthquake due to the damping provided by these devices, obtaining much smaller relative displacements of floors, therefore, the structure with base isolators can remain operative and with minimum or null damages in comparison to a structure with a structural system of fixed base frames.Item type:Ítem, Reducción de la vulnerabilidad sísmica de estructuras ocupacionales de acero en el cantón Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022-03) ;Jiménez López, Geovanny GabrielLópez Villacis, Gonzalo EduardoIn this degree work, a seismic vulnerability study is carried out for two representative structures that constitute the typical occupation given to steel buildings constructed within the urban area of Ambato Canton. These buildings, according to the NEC-2015, are categorized as essential and special type structures respectively. As an initial part, a preliminary design check was performed using the design spectrum prepared according to the standard for this sector, where compliance was reviewed in terms of floor drifts, soft floor and torsion in plan. Subsequently, by means of a nonlinear pushover static analysis, the capacity of the structure and its performance level in the presence of moderate and extreme earthquakes were determined. Likewise, certain influences of the infill masonry used in this type of structures were determined, and finally, according to the performance obtained, a reinforcement was proposed through the use of concentric diagonals and energy dissipaters in order to improve their performance level and avoid their collapse.Item type:Ítem, Análisis del peligro sísmico utilizando el método determinista en el sector Pishilata barrio Pasochoa del cantón Ambato – provincia de Tungurahua(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2020) ;Molina Villamarín, Mayra del RocíoNavarro Peñaherrera, Carlos PatricioThe purpose of this experimental work is to evaluate the period of vibration of three type structures located in the study area and obtain a deterministic spectrum for this sector expressed as the acceleration of gravity Sa (g), and compare it with the spectrum of the NEC 2015. For this, the following steps were carried out: Identify the tectonic regime in the study area, select the geological faults that are longer and closer to the study area and be able to produce a significant movement, such as the Ambato Fault, Huachi, Totoras, Samanga and the Subduction Failure. Using the standard penetration test (SPT) applied at 5 points of the study area, the average shear wave velocity Vs30 approximate for the type of soil profile was calculated, using an empirical correlation between the resistance to standard penetration (N) and the velocity of the shear wave (Vs). The magnitude of momentum for each selected fault was calculated, based on the Wells-Coppersmith methodology, using parameters such as the distance to the epicenter, hypocenter and focal depth. By means of the Prediction Equations of Soil Movement (GMPEs), acceleration spectra are obtained and by means of an envelope of all the maximum acceleration spectra the deterministic spectrum is obtained, which is compared with the response spectrum of the NEC 2015. With these obtained spectra, 3 type structures of the study area were analyzed bymeans of the ETABS program, to observe their behavior before seismic events.Item type:Ítem, Determinación del peligro sísmico determinista para las estructuras del sector Pishilata ubicado entre las calles Troncal de la Sierra, Real Audiencia de Quito, Horacio e Hipócrates de la ciudad de Ambato(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2019) ;Sevilla Samaniego, Jairo AlejandroCevallos Cabrera, Jorge WashingtonThe purpose of this research project is to calculate the period of vibration of three type structures located in the study area, also to obtain a deterministic spectrum for this sector expressed as the acceleration of gravity Sa (g), to compare it with the response spectrum of the NEC 2015. For this process, the following steps were carried out: Identify the tectonic regime in the study area, select the seismic sources (geological faults) with the longest length and the closest ones capable of producing a significant movement that affect the study site, such as Ambato, Huachi, Totoras, Samanga and Subduction failure fail. By means of the standard penetration test (SPT) the average speed of the shear wave Vs30 approximate for the type of profile was calculated using an empirical correlation between the uncorrected standard penetration resistance (N) and the shear wave velocity (Vs). The magnitude of momentum for each selected fault was calculated, based on the Wells-Coppersmith methodology, using parameters such as the distance to the epicenter, hypocenter and focal depth. Through the Soil Movement Prediction Equations (GMPEs) you get acceleration spectra and through an envelope of all spectra of maximum acceleration the deterministic spectrum is achieved, which is compared with the response spectrum of the NEC 2015. The accelerations given by the deterministic spectrum for buildings that have structural periods between 0.10s to 0.60s are greater than the spectrum of the NEC 2015, which means that structures with 1 to 5 floors have a higher degree of risk.Item type:Ítem, Estudio de peligro sísmico determinista para las estructuras de Ambato sector la Universal ubicado entre las calles Bolivariana, Hipócrates, Jenofonte, Horacio, Real Audiencia y Pitágoras(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civil, 2019) ;Guamani Aguayo, Holger FabricioUreña Aguirre, Maritza ElizabethThe present experimental work has been made with the purpose to evaluate the seismic danger existing at the area “La Universal” from Ambato city, through the method deterministic seismic danger. For the develop of the investigation the tectonic regime was define based on the area in analysis, was selected faults nearest and active to the study area, also was made the Standard Penetration Test (SPT), this test was done on five points of the area with the purpose to get kind of existing soil and through this information it was calculated the cutting wave speed (Vs30) to determinate the soil profile with the table provides by NEC-2015. Similarly, through the method of Wells- Coppersmith was calculate the Magnitude of the Moment Weight (Mw) for all failure selected, and through prediction equations of soil movement, we proceeded to calculate acceleration spectra for each fault, using an envelope, from that was determined a specific spectrum for the area, the same that is compared with NEC-2015. The determine spectrum generates greater accelerations with regard stablished spectrum in the NEC-2015 in a period 0.15 to 0.4 seconds, that established that structures will be affected, It determines that the spectrum influences to the structures that are in the area, through the investigation, was determined that structures under five floors, have more seismic threat.
