Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
3 resultados
Resultados de la búsqueda
Item type:Ítem, Caracterización del comportamiento frente al fuego de tres tipos de suelos de las parroquias: Cotundo, San Pablo de Ushpayucu, y Archidona cabecera cantonal, provincia de Napo utilizados en obras civiles(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01) ;Rosero Toalombo Christofer Adrian ;Pérez Maldonado Ruth LorenaUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThis study addressed the thermal susceptibility of Amazonian soils in the parishes of Cotundo, San Pablo de Ushpayacu, and Archidona La Cabecera Cantonal in the Napo province, driven by the increasing risk of wildfires. The main objective was to quantify the physicomechanical, hydraulic, and bearing capacity changes of the material when subjected to a controlled temperature of 750 °C. All geotechnical procedures were carried out based on international standards such as ASTM and AASHTO, contrasting the properties of the materials in their natural state against their post-thermal treatment state. The results indicated an irreversible geomechanical degradation. The CBR residual bearing capacity support a critical collapse, with San Pablo de Ushpayacu being the most affected parish, registering a variation of 34.00%. The loss of support was due to clay deactivation and the decrease in the plasticity index, where Cotundo exhibited the lowest resistance, with an absolute decrease of 29.53% in its plasticity index. Hydraulic conductivity showed an increase across the three samples, with Cotundo marking an 82.46% increase in permeability due to the elimination of the soil's organic fraction. The time-monitored tests determined that the soil is non-combustible. It was concluded that fire significantly affects soil stability, rendering them mechanically unstable but highly permeable.Item type:Ítem, Caracterización del comportamiento frente al fuego del suelo de las comunidades de Santa Clara, San Jorge y Rey de Oriente, cantón Santa Clara, provincia de Pastaza empleados en obras civiles(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-06-30) ;Durán Muñoz Melanie Dayanara ;Gallardo Donoso Lidia JhoannaUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThe research characterizes the physical and mechanical behavior of soils from Santa Clara, San Jorge, and Rey de Oriente, Santa Clara canton, Pastaza, after exposure to 750 °C. The study addresses the limited information available on how fire alters the geotechnical properties of Amazonian soils. Samples were analyzed in their natural condition and after thermal treatment through grain size distribution, Atterberg limits, specific gravity, permeability, modified Proctor, CBR, and flammability tests, following ASTM, AASHTO, and NTE INEN standards. Results showed differentiated alterations depending on each soil. Fine content increased in all cases; Rey de Oriente recorded the highest increment, from 5.55% to 11.88%. Atterberg limits decreased in all three soils; Rey de Oriente showed the most pronounced reduction, with its plasticity index dropping 62.82%. Specific gravity increased only in Santa Clara, while the other two decreased due to intergranular expansion. Rey de Oriente's permeability decreased 56.76%, shifting from low to very low permeability category. All three soils increased their maximum dry density and reduced their optimum moisture content. CBR maintained or slightly improved bearing capacity, preserving the subgrade classification. No soil exhibited spontaneous ignition, although all showed visible physical changes such as color alteration and particle disaggregation. It is concluded that fire significantly modifies plasticity and permeability without compromising bearing capacity, providing a technical foundation for geotechnical risk management in Amazonian areas with a history of forest firesItem type:Ítem, Caracterización del comportamiento frente al fuego de tres tipos de suelos provenientes de las parroquias Veracruz, Fátima, Simón Bolívar de la provincia de Pastaza utilizados en obras civiles(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16) ;Yugcha Paredes Lissette Monserrath ;Pérez Maldonado Ruth LorenaUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería CivilThis experimental research addresses the alteration of soil properties in tropical regions specifically in the parishes of Veracruz, Fátima, and Simón Bolívar in the Province of Pastaza after exposure to a temperature of 750 °C, simulating the thermal impact of forest fires. The main objective is to evaluate the physical and mechanical properties of these soils in their natural state and subsequently under elevated temperature conditions, establishing a comparative analysis between both scenarios. This study arises from the absence of technical parameters or regulations that enable the design of infrastructures in areas susceptible to forest fires. The research follows an experimental approach developed in three key phases. The first phase focuses on the assessment of physical properties through particle-size distribution, specific gravity, Atterberg limits, and permeability tests. The second phase evaluates mechanical behavior using the Modified Proctor Type B test and the California Bearing Ratio (CBR). Finally, flammability tests were conducted to qualitatively determine changes in the samples. The methodology employed relied on international standards such as the ASTM (American Society for Testing and Materials) and national regulations including the NTE (Norma Técnica Ecuatoriana) and INEN (Instituto Ecuatoriano de Normalización). The results reveal irreversible changes in soil structure. Overall, clay dehydroxylation and slight modifications in particle-size distribution were observed, as well as a reduction in specific gravity. In the parishes of Fátima and Veracruz, the plasticity index decreased by 57.45% and 23.78%, respectively, indicating a transition toward less cohesive soils. Mechanically, all samples subjected to high temperatures exhibited a loss of bearing capacity; the most affected was the soil from Simón Bolívar, where the CBR value decreased from 10.10% to 7.50% after thermal exposure. Additionally, flammability tests revealed qualitative color changes in certain portions of the samples.
