Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 2 de 2
  • Item type:Ítem,
    Análisis dinámico no lineal del edifico Residencia López del Cantón Ambato, sector Simón Bolívar, en base a la NEC 2024
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-29)
    Parra Yagual Briggite Jessica
    ;
    Cevallos Cabrera Jorge Washington
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This study presents a comprehensive seismic evaluation of the Residencia López building, located in the Simón Bolívar sector of the Ambato canton, with the purpose of determining its structural behavior considering both the NEC-2015-SE-DS criteria and the proposed NEC-2024-SE-DS update. The four-story reinforced concrete building exhibits certain plan and elevation irregularities. To achieve this, the research was organized into three main phases. In the first phase, the current condition of the structure was verified through tests carried out directly on site. Reinforcement scanning was performed on beams and columns, a rebound hammer test was conducted to estimate the concrete strength, and a standard penetration test was used to characterize the soil. This information provided reliable parameters for developing the structural model. In the second phase, a numerical model was created in ETABS 16, incorporating the actual dimensions of the structural elements, the evaluated material properties, and the building’s irregularities. The design spectra of NEC-2015-SE-DS and the proposed NEC-2024-SE-DS were implemented, allowing the execution of the modal spectral analysis and the verification of key parameters such as the fundamental period, modal mass participation, base shear, and allowable drifts. Additionally, three real accelerograms from the 2016 Pedernales earthquake were selected and scaled to the elastic spectra to perform time-history analyses and observe the structure’s dynamic response. The third phase focused on the evaluation of the building. In the Pushover analysis, capacity curves were generated in the four principal directions, showing that the performance point remained within the Operational and Immediate Occupancy levels. This indicates that the building retains a good reserve of strength and stiffness, without approaching severe damage conditions. In the Nonlinear Time-History analysis, results showed that the beams remained almost entirely within the elastic range, and only one column exhibited the onset of plasticity. The drifts obtained for the applied accelerograms stayed below the limits established in NEC-2024- SE-DS, confirming a satisfactory dynamic performance under real seismic events.
  • Item type:Ítem,
    Análisis estructural del desempeño sísmico del edificio del Hospital Veterinario de la Universidad Técnica de Ambato, mediante la medición de vibraciones
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civil, 2021-09)
    Barrera Moreno, Erik Alexander
    ;
    Ureña Aguirre, Maritza Elizabeth
    Two methods were used in this document, qualitative and quantitative, for the first, Rapid Visual Screening (RVS) is performed according to FEMA 154, supported by the NEC 2015, where it was determined that the structure has a high degree of vulnerability to earthquakes due to a pathological problem of short column generating a very severe irregularity in elevation. On the other hand, for the quantitative method, the non-linear static analysis is performed by means of the Etabs software. With the information obtained on site, two models were carried out, the spectral modal analysis of which the linear behavior of the structure, vibration periods, basal shear and floor drifts were analyzed, as well as the non-linear static analysis the structure capacity curve for X and Y, the performance point of said structure was also determined. The analysis determined the most appropriate method for the local reinforcement of some beams and columns of the structure, being the metal encasing with angles and plates the most practical and economical, a method that considerably increases the capacity of the structural elements to withstand the forces applied on them. In this way, it was possible to give the necessary capacity to all the components of the structure without altering the excellent global behavior of the building, thus meeting the performance expected for the building