Ingeniería Civil y Mecánica

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898

Examinar

Resultados de la búsqueda

Mostrando 1 - 6 de 6
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos de las parroquias: Cotundo, San Pablo de Ushpayucu, y Archidona cabecera cantonal, provincia de Napo utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01)
    Rosero Toalombo Christofer Adrian
    ;
    Pérez Maldonado Ruth Lorena
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This study addressed the thermal susceptibility of Amazonian soils in the parishes of Cotundo, San Pablo de Ushpayacu, and Archidona La Cabecera Cantonal in the Napo province, driven by the increasing risk of wildfires. The main objective was to quantify the physicomechanical, hydraulic, and bearing capacity changes of the material when subjected to a controlled temperature of 750 °C. All geotechnical procedures were carried out based on international standards such as ASTM and AASHTO, contrasting the properties of the materials in their natural state against their post-thermal treatment state. The results indicated an irreversible geomechanical degradation. The CBR residual bearing capacity support a critical collapse, with San Pablo de Ushpayacu being the most affected parish, registering a variation of 34.00%. The loss of support was due to clay deactivation and the decrease in the plasticity index, where Cotundo exhibited the lowest resistance, with an absolute decrease of 29.53% in its plasticity index. Hydraulic conductivity showed an increase across the three samples, with Cotundo marking an 82.46% increase in permeability due to the elimination of the soil's organic fraction. The time-monitored tests determined that the soil is non-combustible. It was concluded that fire significantly affects soil stability, rendering them mechanically unstable but highly permeable.
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos de las parroquias de Teniente Hugo Ortiz, El Triunfo y Canelos, cantón Pastaza, provincia de Pastaza, utilizados en obras civiles.
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-07-01)
    Miranda Ramos Sebastián Alejandro
    ;
    Arellano Yasaca Diana Victoria
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This research focused on the limited knowledge regarding changes in soil structure when subjected to high temperatures in the Amazon region, specifically in the parishes of Teniente Ortiz, El Triunfo, and Canelos, in the Pastaza canton, most often caused by forest fires. The objective of this research was to determine a significant change in soil structure, that is, in its physical and mechanical properties and its bearing capacity, both in its natural state and after exposure to a simulated fire environment with a controlled temperature of 750 °C. To achieve this objective, an experimental methodology was carried out, divided into three phases. The first phase involved characterizing index properties through soil tests in its natural state and post-exposure. The second phase aimed to determine the changes produced in the mechanical properties of the soils, and the third phase qualitatively assessed the flammability of each soil. With the results obtained, the Jamovi software was used, which allowed us to perform a statistical analysis with the data analyzed. The methods used were the Student's t-test for the comparison between natural and exposed soil in each parish and ANOVA for a comparison between the three parishes to be studied, determining that exposure to fire does cause significant changes in the soil.
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego del suelo de las comunidades de Santa Clara, San Jorge y Rey de Oriente, cantón Santa Clara, provincia de Pastaza empleados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-06-30)
    Durán Muñoz Melanie Dayanara
    ;
    Gallardo Donoso Lidia Jhoanna
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The research characterizes the physical and mechanical behavior of soils from Santa Clara, San Jorge, and Rey de Oriente, Santa Clara canton, Pastaza, after exposure to 750 °C. The study addresses the limited information available on how fire alters the geotechnical properties of Amazonian soils. Samples were analyzed in their natural condition and after thermal treatment through grain size distribution, Atterberg limits, specific gravity, permeability, modified Proctor, CBR, and flammability tests, following ASTM, AASHTO, and NTE INEN standards. Results showed differentiated alterations depending on each soil. Fine content increased in all cases; Rey de Oriente recorded the highest increment, from 5.55% to 11.88%. Atterberg limits decreased in all three soils; Rey de Oriente showed the most pronounced reduction, with its plasticity index dropping 62.82%. Specific gravity increased only in Santa Clara, while the other two decreased due to intergranular expansion. Rey de Oriente's permeability decreased 56.76%, shifting from low to very low permeability category. All three soils increased their maximum dry density and reduced their optimum moisture content. CBR maintained or slightly improved bearing capacity, preserving the subgrade classification. No soil exhibited spontaneous ignition, although all showed visible physical changes such as color alteration and particle disaggregation. It is concluded that fire significantly modifies plasticity and permeability without compromising bearing capacity, providing a technical foundation for geotechnical risk management in Amazonian areas with a history of forest fires
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos provenientes de las parroquias Tanicuchi, Mulalo, Pastocalle de la provincia de Cotopaxi utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-06-30)
    Zapata Mena Alex Daniel
    ;
    Arellano Yasaca Diana Victoria
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    In the Cotopaxi province, urban growth towards areas such as Tanicuchí, Mulaló, and Pastocalle faces severe structural uncertainty due to wildfires, given the lack of data quantifying the thermomechanical alteration of foundation soils. Facing this problem, the general objective was to analyze the fire reaction of three types of soils used in civil construction, to provide detailed information on their behavior and establish guidelines that improve safety in construction works. A quantitative experimental study was developed, comparing the natural and calcined states (750 °C) using parametric statistics (Student's t-test and ANOVA). The results show significant alterations (p < 0.05). In Tanicuchí and Pastocalle, thermal crushing generated an increase of 6.74% and 10.57%, respectively, in inorganic fines (filler effect), reducing permeability to 2.12 x 10⁻⁵ cm/s and 3.80 x 10⁻⁵ cm/s. Mulaló registered an increase in hydraulic conductivity, reaching 2.97 x 10⁻⁴ cm/s. Under confinement, the CBR test showed mechanical increases, reaching post-ignition values of 8.10%, 5.40%, and 3.37% (Tanicuchí, Mulaló, and Pastocalle). By maintaining a nonplastic (NP) condition in both phases, this granular degradation suggests hydric vulnerability in the field. Finally, the samples did not show ignition; however, the severe geomechanical change suggests restricting their direct use as subgrades without stabilization.
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos provenientes de las parroquias Pano, Muyuna y Puerto Napo de la provincia de Napo utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16)
    Rivadeneyra Loor Melanie Gabriela
    ;
    Pérez Maldonado Ruth Lorena
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    The present research addressed the problem of the thermal susceptibility of soils used in civil works within the Amazon Region, specifically in the Pano, Muyuna, and Puerto Napo parishes of Napo province, facing the growing threat of forest fires. The main objective was to quantify the alteration of the material's physico-mechanical properties and bearing capacity when subjected to a controlled temperature of 750ºC. To achieve this, a comparative experimental methodology was implemented, structured around standardized laboratory tests, including grain size analysis, Atterberg limits, permeability, Modified Proctor (Type B), and the California Bearing Ratio (CBR). All geotechnical procedures were rigorously executed following international ASTM and AASHTO standards, in addition to national NTE INEN standards, which guaranteed the traceability, precision, and replicability of the results by contrasting the soil in its natural state versus the post-thermal treatment state. The results demonstrated an irreversible and significant alteration in the material's properties. A systematic reduction in the structural capacity was verified, with the Pano sample experiencing the greatest loss of support, showing a decrease in CBR of 32.86%, confirming that heat exposure negatively affects its subgrade classification. This loss correlated with a critical reduction in cohesion and plasticity, being more pronounced in Puerto Napo with a decrease in the Plasticity Index of 62.78%. In contrast, thermal stress generated beneficial secondary effects on the hydraulic properties, recording an increase in the permeability coefficient (k) in all three samples, showing increases of up to 96.44% in the Muyuna parish sample, attributed to the combustion of organic matter and micro-fissuring of the matrix. The synthesis of the findings concluded that fire exposure compromises the soil's structural stability, transforming it into a more fragile material, but one with better drainage capacity, which is fundamental for risk management in the region's engineering.
  • Item type:Ítem,
    Caracterización del comportamiento frente al fuego de tres tipos de suelos provenientes de las parroquias Veracruz, Fátima, Simón Bolívar de la provincia de Pastaza utilizados en obras civiles
    (Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil, 2026-01-16)
    Yugcha Paredes Lissette Monserrath
    ;
    Pérez Maldonado Ruth Lorena
    ;
    Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Civil
    This experimental research addresses the alteration of soil properties in tropical regions specifically in the parishes of Veracruz, Fátima, and Simón Bolívar in the Province of Pastaza after exposure to a temperature of 750 °C, simulating the thermal impact of forest fires. The main objective is to evaluate the physical and mechanical properties of these soils in their natural state and subsequently under elevated temperature conditions, establishing a comparative analysis between both scenarios. This study arises from the absence of technical parameters or regulations that enable the design of infrastructures in areas susceptible to forest fires. The research follows an experimental approach developed in three key phases. The first phase focuses on the assessment of physical properties through particle-size distribution, specific gravity, Atterberg limits, and permeability tests. The second phase evaluates mechanical behavior using the Modified Proctor Type B test and the California Bearing Ratio (CBR). Finally, flammability tests were conducted to qualitatively determine changes in the samples. The methodology employed relied on international standards such as the ASTM (American Society for Testing and Materials) and national regulations including the NTE (Norma Técnica Ecuatoriana) and INEN (Instituto Ecuatoriano de Normalización). The results reveal irreversible changes in soil structure. Overall, clay dehydroxylation and slight modifications in particle-size distribution were observed, as well as a reduction in specific gravity. In the parishes of Fátima and Veracruz, the plasticity index decreased by 57.45% and 23.78%, respectively, indicating a transition toward less cohesive soils. Mechanically, all samples subjected to high temperatures exhibited a loss of bearing capacity; the most affected was the soil from Simón Bolívar, where the CBR value decreased from 10.10% to 7.50% after thermal exposure. Additionally, flammability tests revealed qualitative color changes in certain portions of the samples.