Ingeniería Civil y Mecánica
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/898
Examinar
3 resultados
Resultados de la búsqueda
Item type:Ítem, Desarrollo de un procedimiento de inspección termográfica infrarroja para la detección temprana de anomalías térmicas en calderas industriales, como herramienta de mantenimiento predictivo(Universidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería Mecánica, 2026-07-05) ;Canseco Suárez Angelo Alexis ;Carrillo Rosero Carlos MauricioUniversidad Técnica de Ambato-Facultad de Ingeniería Civil y Mecánica-Carrera de Ingeniería MecánicaThis technical project developed an infrared thermographic inspection procedure for the early detection of thermal anomalies in industrial boilers as a predictive maintenance tool. The study was conducted in four dairy-producing companies located in Píllaro Canton, Tungurahua Province, all equipped with 60 BHP water-tube boilers. The methodology combined systematic visual inspection based on IEC 60812, comparative qualitative thermography using a FLIR E8 thermal camera, and the quantification of energy losses through heat transfer equations for convection and radiation. The procedure was structured in accordance with international standards, including ISO 18434-1, ASTM E1934, API 573, ASME Section VII, NFPA 85, and IEC 60812:2018, ensuring technical rigor and reproducibility in industrial environments. The results revealed critical thermal anomalies in three of the four units evaluated, with surface temperatures exceeding the ranges accepted by the standards, indicating advanced deterioration of the refractory material.A temperature-differential criticality matrix with four severity levels was implemented: normal (60 °C), facilitating the objective prioritization of maintenance interventions. The procedure was validated through a corrective intervention on Boiler C, achieving a temperature reduction that resulted in an approximate 95% decrease in thermal losses and significant cost savings in No. 2 diesel fuel consumption. It is concluded that infrared thermography, integrated into a standardized procedure and supported by Failure Mode and Effects Analysis (FMEA), constitutes an effective, non-invasive, and highly cost-efficient tool for predictive maintenance management in industrial boilers, enabling the transition from a reactive maintenance approach to one based on the actual condition of the equipmentItem type:Ítem, Análisis térmico para evaluar eficiencia en un calderín Pirotubular de 2 BHP del laboratorio de la Carrera de Ingeniería Mecánica(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2019) ;Sánchez Mendoza, Alejandro SebastiánCabrera Anda, Santiago PaúlWas evaluated efficiency by applying techniques of thermography in a 2BHP boiler of the career of mechanical engineering of the Technical University of Ambato. The data were taken using technological equipment: thermal camera, thermocouple, thermometer digital, bimetal thermometer, combustion gas analyzer and volumetric meter of GLP. Was obtained thermograms, temperature of gases, temperature of steam pipes, composition of gases, volumetric composition of products and consumption of GLP.Analysis was performed using the indirect method, was calculated losses caused by heat transfer (convection and radiation) 17.4%, combustion 5.17%, unburnt 8.7% and not quantified losses 10%. Was determined an efficiency of 59%. Finally, was proposed four proposals to improve the functioning of the boiler and was executed maintenance cleaning of tubes and burner due to time a financial resource, obtaining a fuel-saving of 0.12 kg/h and the reduction in the temperature of the combustion gases.Item type:Ítem, Estudio de parámetros de combustión en un calderín de 2 bhp y su efecto sobre la eficiencia(Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Mecánica, 2011) ;Vacacela Miranda, Wilmo MarlonCabrera Anda, Santiago PaúlEl presente trabajo de investigación se orientó en analizar el funcionamiento de un calderín de 2 BHP y la influencia de la variación de los parámetros de combustión, que para este caso fueron la presión del combustible y el caudal, sobre la eficiencia, y tener la oportunidad en lo posterior de incorporar procesos útiles. El proyecto tiene como objetivo general, analizar el efecto de incidencia de los parámetros de combustión y su efecto sobre la eficiencia, mediante la variación de los parámetros de combustión, determinar un rango de trabajo óptimo o el más apropiado para el calderín; con respecto a la hipótesis, se plantearon en base a cuan precisos podemos ser en cuanto a la eficiencia del caldero respecto a un modelo operativo o de diseño. La investigación que comprende este trabajo es de nivel experimental y de tipo exploratorio; dentro de la misma se realizaron ensayos experimentales de variación de presión de GLP y variación de caudal de alimentación de GLP. Los resultados recopilados se encuentran en tablas, entre las que podemos mencionar, Eficiencia vs. Presión de GLP, Eficiencia vs. Entalpia, Presión de proceso vs. tiempo, en función de la presión de combustible y la variación de caudal de GLP; Todas estas representadas gráficamente con puntos de dispersión entre todos los parámetros de estudio, a presiones de combustible bajas entre la cuales fueron de 0.4, 0.5 y 1 PSI, las eficiencias son muy similares entre si, pero al momento que trabaja con 2 PSI ésta varía notablemente mostrando una caída aproximada de un 15%, para los 2 casos como fueron el trabajar con un caudal del 100% y del 75%, en cuanto a su desempeño. Finalmente en el capitulo seis se propone el diseño y la construcción de un calderín de 2 BHP con una eficiencia de diseño del 65% aproximadamente, para lograr llevar a cabo nuestro estudio.
