Ciencias de la Salud

URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/813

Examinar

Resultados de la búsqueda

Mostrando 1 - 6 de 6
  • Item type:Ítem,
    EFECTOS DEL TABAQUISMO SOBRE LA FUNCIÓN PULMONAR Y LA APTITUD FÍSICA EN PERSONAS FUMADORAS
    (2026-01-27)
    Pérez Miranda, Stalin Ariel
    ;
    Caiza Lema, Stalin Javier
    ;
    Universidad Técnica de Ambato / Facultad de Ciencias de Salud / Carrera de Fisioterapia
    Smoking is not only one of the leading causes of preventable death worldwide, but it also causes a progressive decline in the physical health of smokers. Therefore, it is crucial to understand and quantify the impact of tobacco use on the body. Thus, the objective of this research project was to analyze the relationship between pulmonary function tests and smoking history. The research was conducted within the field of human health, focusing on chronic non-communicable diseases, using a crosssectional, non-experimental, mixed-methods design. Thirty active smokers from the village of Quinchibana Alto participated. The Fagerström Test (nicotine dependence), the International Physical Activity Questionnaire (IPAQ), portable spirometry (pulmonary function), and the 6-minute walk test (physical fitness) were used for assessment. The most important finding was that, although the sample did not present a significant obstructive ventilatory pattern, clear statistical relationships were identified between the smoking index and estimated respiratory values (FEV1 and FEV1/FVC). This indicates that the greater the cumulative tobacco consumption, the greater the deterioration of lung function compared to what would be expected for each participant's age and height. The main recommendation is to implement regular spirometric monitoring programs, especially for heavy smokers, to detect respiratory alterations early and reduce the risk of developing irreversible chronic lung diseases.
  • Item type:Ítem,
    VALORES ESPIROMÉTRICOS EN ESTUDIANTES DE EDUCACIÓN TÉCNICA SUPERIOR QUE USAN VAPER
    (2025-07-21)
    Hidalgo Toapanta Bryan Alejandro
    ;
    Peñafiel Luna Andrea Carolina
    ;
    Universidad Técnica de Ambato / Facultad de Ciencias de Salud / Carrera de Fisioterapia
    Introduction: The use of electronic cigarettes or vapes (Vp) has increased considerably among young people, driven by the perception that they constitute a less harmful alternative to conventional smoking. However, there is growing evidence of their adverse effects on respiratory health, particularly in young individuals without pre-existing pulmonary conditions. Objective: This study evaluated the relationship between electronic cigarette (vape) use and pulmonary function in higher technical education students at the Instituto Tecnológico La Maná. Methods: Using standardized spirometry tests, parameters such as Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), and the FEV1/FVC ratio were measured in a sample of 50 participants. In addition, a structured record of vape usage patterns was applied, enabling analysis of consumption frequency and duration. Results: The findings revealed a significant decline in spirometric values, especially among individuals with higher inhalation frequency and cumulative usage time. Strong negative correlations were identified between Vp use and the main indicators of lung function, suggesting early respiratory impairments with mild obstructive patterns. Statistical analysis confirmed that pulmonary deterioration is associated with the intensity and chronicity of Vp use, although individual variables such as BMI and sex were also observed. Conclusions: These findings support emerging concerns in the scientific literature regarding the respiratory impact of vaping on young populations, even in the absence of prior pulmonary history.
  • Item type:Ítem,
    APLICACIÓN DE LA PRUEBA DE PROVOCACIÓN BRONQUIAL CON EJERCICIO EN NIÑOS Y ADOLESCENTES
    (2025-02-27)
    Ramos Meneses, Jonathan Jeziel
    ;
    Caiza Lema, Stalin Javier
    ;
    Universidad Técnica de Ambato/ Facultad de Ciencias de Salud /Carrera de Fisioterapia
    Asthma is one of the most prevalent chronic respiratory diseases in childhood and adolescence. It is characterized by inflammation and bronchial hyperreactivity, which trigger bronchoconstriction and airway obstructions. This condition represents a significant public health issue due to its impact on emergency services, hospitalizations, and school absenteeism. In Ecuador, previous studies have revealed a prevalence of asthma symptoms in adolescents but a low rate of diagnosis, suggesting possible underdiagnosis and insufficient control of the condition. Exercise-induced bronchoconstriction (EIB) is a common manifestation in patients with uncontrolled asthma and can be assessed through provocation tests, such as the Exercise-Induced Bronchial Provocation Test (EIBPT). This study aims to evaluate the bronchial response to the EIBPT in Ecuadorian children and adolescents to contribute to a better understanding of asthma in this population. This non-experimental, descriptive, observational study was conducted on 25 students aged 8 to 17 years without a prior asthma diagnosis. Participants underwent the EIBPT on a treadmill. The criterion for a positive result was set at a decrease in VEF1 %, observed in only 4% of the 25 participants. The low prevalence of EIB in this sample suggests that, in Ecuadorian children and adolescents without a prior asthma diagnosis, exercise does not induce significant bronchoconstriction, ruling out the existence of an asthma underdiagnosis.
  • Item type:Ítem,
    COMPOSICIÓN AMBIENTAL COMO DETERMINANTE EN LA DISMINUCIÓN DE LA FUNCIÓN PULMONAR
    (2025-02-26)
    Soria Arcos, Jinson Enrique
    ;
    Caiza Lema, Stalin Javier
    ;
    Universidad Técnica de Ambato/ Facultad de Ciencias de Salud /Carrera de Fisioterapia
    The following research study was conducted in order to determine whether the levels of environmental pollution are a determinant in lung decline, the study methodology was a quasi-experimental design, cross-sectional type with a quantitative approach, using three assessments, the Air Quality Monitor device that measures the level of pollution components carbon dioxide (CO2), chemical gases (HCHO and TVOC) and particulate matter (PM), the SP10 Spirometer device to assess pulmonary function and the ATSDLD-78 Pulmonary Questionnaire to identify respiratory symptoms, such as respiratory symptoms, Chemical gases (HCHO and TVOC) and particulate matter (PM), the SP10 Spirometer device to evaluate pulmonary function and the ATS-DLD-78 pulmonary questionnaire to identify respiratory symptoms, these evaluations were submitted to 32 people inside the Aldas Tannery in their respective areas and functions. Among the environmental results, it was found that in the Rivera and Terminado areas the contamination levels exceeded the established range, while in the other areas they presented low and normal levels. In the spirometric results, real percentages were obtained above the predicted percentage in the tiffeneau index (FEV/FVC), forced expiratory volume in one second (FEV), forced vital capacity (FVC) and the lower limit of normality (LIN), obtaining normal values for most of the cases. Regarding the results of the questionnaire, the following were identified low levels of respiratory symptomatology. It is concluded that the correlation of the values obtained in the three evaluations does not influence as a determinant in pulmonary decline.
  • Item type:Ítem,
    VARIACIÓN DE LA FUNCIÓN PULMONAR EN RESIDENTES ALTOANDINOS
    (2025-02-26)
    Herrera Quintana, Jose Armando
    ;
    Caiza Lema, Stalin Javier
    ;
    Universidad Técnica de Ambato/ Facultad de Ciencias de Salud /Carrera de Fisioterapia
    Introduction: Lung function in residents of high Andean areas is influenced by physiological adaptations to chronic hypoxia, such as increased hemoglobin concentration, which can affect the interpretation of spirometric tests and complicate the diagnosis of respiratory diseases. Objective: To analyze the variation of lung function in residents of high Andean areas at more than 2,500 meters above sea level. Materials and methods: The study adopted a quantitative and cross-sectional approach, using a spirometer to measure parameters such as Forced Vital Capacity (FVC) and Forced Expiratory Volume in the first second (FEV1), complemented by a standard American Thoracic Society (ATS) questionnaire to assess respiratory symptoms, and applying specific inclusion and exclusion criteria to ensure the validity of the results. Results: The study population included 24 participants, of which 41% were men and 58% women, with an average age of 30.46 years. Men had higher values in lung function compared to women, with real means of 92.70 vs. 89.47 in FEV₁/FVC, 4.80 vs. 2.86 liters in FEV₁ and 5.19 vs. 3.21 liters in FVC, while the prediction percentages were similar between sexes. Spearman's correlation analyses between altitude and pulmonary variables showed no significant associations, with weak correlations and p-values greater than 0.05, indicating that altitude did not have a notable impact on the lung function of this sample. Conclusions: Spearman's correlation analysis between altitude and lung function showed that no correlation was statistically significant (all p-values greater than 0.
  • Item type:Ítem,
    VALORES ESPIROMETRICOS ESTIMADOS MEDIDOS POR ENVERGADURA Y TALLIMETRIA EN ADULTOS MAYORES
    (Universidad Técnica de Ambato/ Facultad de Ciencias de Salud /Carrera de Fisioterapia, 2024-03-18)
    Montero Merino, Zenaida Milena
    ;
    Caiza Lema, Stalin Javier
    The research focuses on determining estimated spirometric values measured by wingspan and height measurement in addition to analyzing the variability that may or may not exist between these two variables. The study population was 43 older adult participants between the ages of 65 and 90; data was collected on weight, height, sex, age, and wingspan. The evaluation of lung function was carried out through a spirometric examination and the parameters of FEV1, FVC, and Tiffeneau Index were analyzed. The project design is prospective-transversal with a non-experimental-analyticalrelational quantitative approach. A single evaluation was made that yielded numerical and categorical values that were analyzed with the Chi-square statistical test. Spirometric values were obtained for both height and wingspan. The statistical analysis yielded a result of p 0.000, indicating perfect agreement between the variables studied, supporting the true hypothesis of the research where it is mentioned that there is no variability between the values. In conclusion, the use of wingspan would be the most appropriate alternative to height for the analysis of lung function.