Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/36463
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorFrías Torres, Alex Xavier-
dc.contributor.authorChicaiza Valencia, Karla Leticia-
dc.contributor.authorParedes Ramos, Katherine Carolina-
dc.date.accessioned2022-09-29T23:26:48Z-
dc.date.available2022-09-29T23:26:48Z-
dc.date.issued2022-09-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/36463-
dc.descriptionDebido a que los barrios La Merced y San Luis pertenecientes al cantón Patate no cuentan con uno de los principales servicios básicos como es el alcantarillado sanitario y pluvial y a pesar de ser sectores turísticos y residenciales se presenta el estudio y diseño del mismo. Se realizó un levantamiento topográfico mediante Estación Total y fotogrametría en un área de 68.17 ha, datos que fueron procesados en un software y mediante la ortofoto se obtuvo la población futura necesaria para el diseño de caudales. Para el diseño de alcantarillado sanitario que tiene 6.73 km se utilizó una tubería PVC de 200mm que transportará un caudal de diseño de 5.58 l/s, mientras que para el alcantarillado pluvial de 6.36 km se usó tuberías PVC de 250, 300, 364, 400, 500, 600 y 700mm que transportarán un caudal de diseño de 594.78 l/s. Además, se diseñó la planta de tratamiento de aguas residuales, la misma que consta de un canal de desbaste, criba, tanque Imhoff, lecho de secado de lodos y dos humedales de flujo sub superficial. Para finalizar se obtuvo un presupuesto referencial y análisis de precios unitarios con sus respectivas especificaciones técnicas.es_ES
dc.description.abstractDue to the fact that the La Merced and San Luis neighborhoods belonging to the Patate canton do not have one of the main basic services such as sanitary and storm sewerage and despite being tourist and residential sectors, the study and design of the same is presented. A topographic survey was carried out using Total Station and photogrammetry in an area of 68.17 ha, data that was processed in software and through orthophoto the future population necessary for the design of flows was obtained. For the sanitary sewer design, which is 6.73 km long, a 200mm PVC pipe was obtained that will transport a design flow of 5.58 l/s, while for the 6.36 km storm sewer, 250, 300, 364, 400 PVC pipes were used. , 500, 600 and 700mm that will transport a design flow of 594.78 l/s. In addition, the wastewater treatment plant was grouped, which consists of a roughing channel, screen, Imhoff tank, sludge drying bed and two subsurface flow wetlands. Finally, a reference budget and unit price analysis were obtained with their respective technical specifications.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectALCANTARILLADO SANITARIOes_ES
dc.subjectALCANTARILLADO PLUVIALes_ES
dc.subjectPLANTA DE TRATAMIENTOes_ES
dc.subjectTUBERÍA PVCes_ES
dc.subjectPRESUPUESTOes_ES
dc.titleDiseño del sistema de alcantarillado sanitario y pluvial para mejorar la calidad de vida de los barrios La Merced y San Luis de la parroquia La Matriz, cantón Patate, provincia de Tungurahuaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I.C. 1646 - Paredes Ramos Katherine Carolina y Chicaiza Valencia Karla Leticia.pdfTESIS A TEXTO COMPLETO18,15 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.