Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/26947
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorZaldumbide Ortiz, Francisco Xavier-
dc.contributor.authorGalarza Chacón, Raúl Fernando-
dc.date.accessioned2017-12-11T19:55:47Z-
dc.date.available2017-12-11T19:55:47Z-
dc.date.issued2017-
dc.identifier.othert1350mshi-
dc.identifier.urihttp://repositorio.uta.edu.ec/jspui/handle/123456789/26947-
dc.descriptionLas unidades de transporte urbano en condiciones ambientales adecuadas son un sitio ideal para el crecimiento de bacterias. La investigación realizada partió del estudio exploratorio con la validación del problema de la contaminación ambiental microbiológica mediante análisis cualitativo y cuantitativo de las superficies inertes de los buses que están en contacto directo con las manos de las personas. La metodología contempló la utilización de métodos validados para la toma y análisis de las muestras, tales como: hisopado de superficies, cultivo de microorganismos en medios generales y específicos, Microgen y placas Petri film para confirmación y cuantificación de un microorganismo específico. Los resultados arrojaron que 9 de cada 10 unidades poseen algún tipo de bacteria, existiendo prevalencia del Staphylococcus aureus con el 57,69%; el lugar más contaminado del bus es el asidero vertical de botón de parada, seguido del asidero y base del asiento (391,76; 333,46; 228,18 UFC/cm#) respectivamente. Se determinó la incidencia de variables tales como: número de pasajeros por viaje, apertura o cierre de las ventanas, sitio de la toma de muestra y sitios por donde a traviesa la unidad de transporte en el aumento de los niveles de contaminación. La propuesta determinó que el acero inoxidable AISI 304, aluminio AA 6061 y acero con recubrimiento polimérico no son recomendados para la utilización en los asideros de los buses, aleaciones con porcentajes de cobre mayores al 65% son ideales para estas aplicaciones.-
dc.description.abstractEXECUTIVE SUMMARY Urban transport units in suitable environmental conditions are an ideal site for the growth of bacteria. The research was based on the exploratory study with the validation of the problem of microbiological environmental contamination by qualitative and quantitative analysis of the inert surfaces of the buses that are in direct contact with the hands of the people. The methodology included the use of validated methods for the collection and analysis of samples, such as, swabbing of surfaces, culture of microorganisms in general and specific media, Microgen ID A +B and petrifilm plates for confirmation and quantification of a specific microorganism. The results showed that 9 of 10 units have some type of bacterium. Also, there is a prevalence of Staphylococcus aureus with 57.69%, then the quantitative analysis was performed, which showed that the most contaminated place of the bus is the vertical handle of the stop button, followed by the handle and the seat base (391.76, 333.46, 228.18 UFC/cm#), respectively. The incidence of variables was determined e.g. number of passengers per trip, opening or closing of windows, sampling site, sites where the transport unit crosses in increasing pollution levels, etc. The proposal determined that the following materials are not recommended for use in bus handles: stainless steel AISI 304, aluminum AA 6061, and steel with polymer. On the other hand, alloys with copper percentages greater than 65% are ideal for these applications.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería en Sistemas, Electrónica e Industrial. Maestría en Seguridad e Higiene Industrial y Ambientales_ES
dc.rightsopenAccesses_ES
dc.subjectTRANSPORTE URBANOes_ES
dc.subjectCONTAMINACIÓN MICROBIOLÓGICAes_ES
dc.subjectTRANSPORTE - AMBATOes_ES
dc.subjectSTAPHYLOCOCCUS AUREUSes_ES
dc.titleIncidencia de las rutas del transporte público en la contaminación ambiental microbiana en los asideros de los buses urbanos de la ciudad de Ambatoes_ES
dc.typemasterThesises_ES
Aparece en las colecciones: Maestria en Seguridad e Higiene Industrial y Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis_t1350mshi.pdf22,79 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.