    Simulación de un sistema contra incendios (CFAST), utilizando una solución ignífuga inorgánica diluida, en el área de producción de pasteurizadora El Ranchito
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímica, 2021-09)
    Sunta Gordillo, Jessica Fernanda
    ;
    Sosa Cárdenas, Julio César
    At present, the loss of human lives, as well as materials due to fires within industrial plants is very common, since there are no early detection systems for these accidents, one of the reasons being the cost of implementation. To do this, different computerized systems have been created that allow the prediction of fires, through the application of mathematical calculations, thus reducing these expenses. In this work, the CFAST computer tool was used for the simulation of a firefighting system in the production area of El Ranchito pasteurizer, using sprinklers with diluted inorganic fireproof solutions. For which the type of risk presented by the plant was determined with the help of the NFPA13 and UNE 12845 Regulations, in addition to the extinction conditions, as well as the materials used within the building, for the risk presented by the plant according to the UNE 12845 the design area is 325m2 with a design density of 705 mm per minute. Finally, with the help of CFAST and the Smokeview data visualizer, the difference in the activation times of the sprinklers in the event of a fire was evaluated, with the use of fireproof solution (aluminum hydroxide) using heat release curves (HRR). It was identified that the type of risk for the dairy processor El Ranchito is of type extra risk grade 1, according to the two regulations used. On the other hand, the total area of application was obtained 424.27 square meters, as well as the total number of sprinklers, being 28 for this case. For the simulation, two were performed, the first using sprinklers with water and the second applying 9 percent of the fireproof (Paredes Villacis, 2018). Reducing the HRR curve by 30 percent and sprinkler activation times. So it can be said that better results were obtained by applying the inorganic fireproof Aluminum Hydroxide to 9 percent, because with the application of the solution an improvement of 40 percent in the cooling time of the system was achieved.
  • Item type:Ítem,
    Elaboración de un sistema contra incendios considerando el uso de agua diluido con ignifugo inorgánico (hidróxido de aluminio, hidróxido de magnesio) utilizando la herramienta CFAST en el área de producción de Industrias Licoreras Asociadas (ILA)
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímica, 2021-09)
    Pérez Aldas, Jessica Paola
    ;
    Robalino Martínez, Dolores del Rocío
    A fire protection system minimizes the effects produced by fire. It safeguards people is lives and reduces damage to infrastructure. Nowadays there are specialized softwares that simulate fires. They allow to modify the fire conditions and to observe the damages produced by the fire, without affecting people or influencing the material damages. The design of the fire protection system for the production plant of the company Industrias Licoreras y Asociados (ILA). It was carried out based on NFPA13 (Standard for the Installation of Sprinkler Systems) and UNE EN 12845: 2016 (Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance). For the ILA simulation, experimental conditions were added, such as temperature variations and simulation times, in addition, the surface area of the sprinklers in the area of operation of the plant was calculated, it will have an area for 30 sprinklers and 8 are necessary for the control of the simulated fire. Simulations were also carried out with the addition of flame retardants (alumina hydroxide and magnesium hydroxide), which showed favorable results in terms of reducing the fire development time. The most effective flame retardant was aluminum hydroxide, reducing the fire extinguishing time by 30 percent. The results were compared with other experiments, reaching the same conclusions where fire retardants reduce fires.
  • Item type:Ítem,
    Evaluación de riesgos químicos por Benceno, Tolueno y Xileno en los puestos críticos de los laboratorios de la Universidad Técnica de Ambato
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímica, 2021-03)
    Peralta Álvarez, Katherine Alejandra
    ;
    Córdova Suárez, Manolo Alexander
    An evaluation analysis of volatile organic compounds (VOCs) produced by the different laboratories of the Technical University of Ambato was carried out using the Quality Norm for internal environments ISO 171330. Benzene, toluene, and xylene (BTX) were sampled using the Norm of UNE 689 Chemical Risk Assessment, measurement tests were carried out in the Physical-Chemical and Instrumental Analysis, General Chemistry, and Food Research Center laboratories for 90 working days. The BriD MX6 (direct-photoionized measurement) was used for the measurements. The exposure indices in parts per million (ppm) were: Instrumental Analysis: benzene 10.35, toluene 0.12, xylene: meta 0.08, ortho 0.07, para 0.08, General Chemistry: benzene 22.13, toluene 0.13, xylene: meta 0.17, ortho 0.17 and for 0.12; and the Food Research Center: benzene 17.74, toluene 0.14, xylene: meta 0.13, ortho 0.17 and for 0.15; determining a value of the total exposure index in ppm: Instrumental Analysis of 10.54, general chemistry of 22.71 and the Food Research Center 22.76. Exceeding the Recommended Environmental Limit Value (VLA). Finally, an attenuation system was developed calculating a total ventilation flow for each of the laboratories in cubic meters per hour. Laboratories use BTX in different concentrations, this causes its concentrations to vary. Finally, the total evaporation rate calculated in liters per hour was obtained. The parameters required by the Institute for Occupational Safety and Hygiene (INSHT) were used.by the Institute of Occupational Safety and Hygiene (INSHT) were used.
  • Item type:Ítem,
    Diseño de un sistema contra incendios mediante la utilización de la herramienta CFAST en el Laboratorio de Control y Análisis de Alimentos LACONAL
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímica, 2020-01)
    Zurita Castro, Fernanda Betsabe
    ;
    Córdova Suárez, Manolo Alexander
    A fire simulation was conducted in an enclosed enclosure with CFAST, considering the combustion of office real estate, materials and equipment in the LACONAL of the University Technical of Ambato. The design was developed in two phases. The first with the determination of water extinguishing conditions for an area of 264.04 m2 is obtained 24 sprinklers for an optimal design, considering a total flow rate for the system of 4119.02 L for min and a volume of water for the supply source of 596645.17 L according to NFPA 13 and UNE 12845. The second phase simulated a fire under environmental conditions of average temperature of 20 Celsius degrees, humidity of 53 percent, atmospheric pressure of 101500 Pa and oxygen limits of 5 percent. The simulation time, thermal properties of materials for floor, ceilings and walls, the geometric dimensions and coordinates of each compartment, the location of door and window openings in each of the compartments, HRR curves, the coordinates of each of the objects produced as the fire source, and the location of each sprinkler were determined. The maximum temperature profiles of the hot gases were 114 Celsius degrees at 75 seconds of the simulation. The time when the lab reached 20 Celsius degrees was 2110 seconds and the smoke evacuation time was 10800 seconds in the simulation with sprinklers.
  • Item type:Ítem,
    Evaluación in situ del riesgo toxicológico por inhalación de Butanol, Ciclohexanona y Metilacetato de los trabajadores en el proceso de acabado de productos de un taller de maderas
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímica, 2019-12)
    Villagrán Guerrero, Jéssica del Lourdes
    ;
    Córdova Suárez, Manolo Alexander
    An assessment study of volatile organic compounds (VOC’s) generated in the process of a company's wood products finishing workshop was conducted using the Quality Standard for environments ISO 171330. Cyclohexanone (C6OH10), Methylacetate (C6H12O3) and Butanol (C4H10O) using the UNE 689 Chemical Risk Assessment Standard considering several 983 tests under environmental conditions of: temperature (T) 21 Celsius degrees: 50 percent relative humidity (HR) and atmospheric pressure (Pa) of 1 atm. For concentration measurement, direct measurement equipment with iBRiD MX6 photoionization sensor that meets NIOSH 1300 standards was used. As a result, the most likely value for; cyclohexanone was 21,00 ppm, for methylacetate: 268,74 ppm and for butanol: 311,65 ppm. Exposure rates were: 1.00, 1.34 and 15.58 respectively; determining a value of the total exposure rate of 17.92 that exceeds 1692 percent the Recommended Environmental Limit Value (VLA). To complete the study, an attenuation system was determined by determining a total ventilation flow rate of 18.697 m3 for h; the speed of generation (G) was 0.25 m3 for h, 0.11 m3 for h and 0.14 m3 for h respectively; the total evaporation rate (Et) calculated is 1.9 l for h and the safety factor (K): 1; for this purpose the parameters required by the Institute for Occupational Safety and Hygiene (INSHT) were used.
  • Item type:Ítem,
    Estudio de la contaminación por la presencia de partículas biológicas aerotransportables en el relleno sanitario de la Mancomunidad GIDS Pujilí - Saquisilí
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Carrera de Ingeniería Bioquímica, 2017-12)
    Flores Silva, Valeria Estefanía
    ;
    Córdova Suárez, Manolo Alexander
    The aim of research was to study Study of pollution by the presence of airborne biological particles from the landfill the Commonwealth of GIDS Pujilí-Saquisilí. The sampling taked place in two points, at different times (09h00 and 12h00) and during 10 working days, in situ was registered conditions of temperature and relative humidity. Through air inoculation in the Brain Heart Infusion medium, the microbial concentration in UFC/ml was determined, the analysis showed that concentrations were below the level allowed by International proposals, it attributing the higher concentration to the treatments; a1b1c5 with a value of 22.08 UFC/ml at 17 Celsius degrees and 56 percent RH in the commons waste area and a1b2c2 with a value of 22.32 UFC/ml at 18 Celsius degrees and 52 percent RH in the hospital waste area. From the 40 samples of air taken, 64 bacteria were isolated. That with IMVIC biochemical tests were identified, this analysis showed species with enteric characteristics, such as: Enterococcus faecalis or Shigella flexneri, Salmonella or Citrobacter freundii, Pantoea agglomerans, Enterobacter cloacae type II, Staphylococcus aureus, Klebsiella pneumoniae or Enterobacter, Escherichia coli, Citrobacter Koseri and Klebsiella oxytoca, Moreover, the biological risk to which the workers of the filling were exposed was evalued, this evaluation was based on Royal Decree 664/1997. It was established that air of the landfill is composed of biological agents belonging to groups 2 and 3. This study shows that exists moderate pollution in the facilities
  • Item type:Ítem,
    Desarrollo de instructivos de Seguridad e Higiene Industrial a partir del análisis aerobiológico del relleno sanitario de la Empresa Pública Municipal Gestión Integral de Desechos Sólidos del cantón Salcedo
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Carrera de Ingeniería Bioquímica, 2017-05)
    Vásconez Hurtado, Ingrid Nicole
    ;
    Córdova Suárez, Manolo Alexander
    The aerobiological study was made in the Sanitary Landfill of Salcedo’s city, which process consisted of taking the air with sterile syringes of 20 cm3 and injecting it into 10 ml of Brain-heart infusion medium to incubate the microorganisms at 37°C. The objective was study the proliferation of microorganisms within the human organism, this study was carried out in the solid waste disposal area and the hospital waste area, where the presence of pathogenic microorganisms which may be responsible for infections in the worker was evaluated. To determine the biological risk was taken as reference the Royal Decree 664/1997 which establishes the microorganism’s classification according to their infectious capacity. In this research was found a couple of dangerous bacteria such as Escherichia coli and Salmonella typhi, which belong to the third group of this classification, indicating that these microorganisms are capable to produce serious pathologies and are therefore a serious risk to the worker's health and a possibility of spreading into the community. Due to the present risk in the evaluated area, a biosecurity instructive and an instructive about the use of PPE (personal protection equipment) and occupational hygiene were made, which mitigate the risk due to exposure to Salcedo Municipal GAD workers.
  • Item type:Ítem,
    Desarrollo de instructivos de Seguridad e Higiene Industrial a partir del análisis aerobiológico del relleno sanitario de la Empresa Pública Municipal Gestión Integral de Desechos Sólidos del cantón Salcedo
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Carrera de Ingeniería Bioquímica, 2017-05)
    Solís Sánchez, Diego Alexis
    ;
    Córdova Suárez, Manolo Alexander
    The aerobiological study was made in the Sanitary Landfill of Salcedo’s city, which process consisted of taking the air with sterile syringes of 20 cm3 and injecting it into 10 ml of Brain-heart infusion medium to incubate the microorganisms at 37°C. The objective was study the proliferation of microorganisms within the human organism, this study was carried out in the solid waste disposal area and the hospital waste area, where the presence of pathogenic microorganisms which may be responsible for infections in the worker was evaluated. To determine the biological risk was taken as reference the Royal Decree 664/1997 which establishes the microorganism’s classification according to their infectious capacity. In this research was found a couple of dangerous bacteria such as Escherichia coli and Salmonella typhi, which belong to the third group of this classification, indicating that these microorganisms are capable to produce serious pathologies and are therefore a serious risk to the worker's health and a possibility of spreading into the community. Due to the present risk in the evaluated area, a biosecurity instructive and an instructive about the use of PPE (personal protection equipment) and occupational hygiene were made, which mitigate the risk due to exposure to Salcedo Municipal GAD workers.
  • Item type:Ítem,
    Aplicación de normas técnicas y legales de ambiente y seguridad industrial en la elaboración de Planes de Manejo Ambiental de obras civiles.
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Maestría en Producción más Limpia., 2015)
    Garcés Acuña, Diana Lucía
    ;
    Córdova Suárez, Manolo Alexander
    This research aims to analyze the application of technical and legal standards of environment and safety and how this affects the elaboration of environmental management plans that are part of Impact Assessments in civil works projects, these are documents required in the process of certification by the Ministry of Environment for the prevention and control of pollution. The parameters established in the Unified Text of Secondary Environmental Legislation, are the general guidelines for the preparation of management plans, based on analysis and critical interpretation. As a result, we find that the parameters mentioned, provide a number of proposals from consulting services in projects of the same branch of activity, in this case, civil works, where the flow of frequent process allows anticipating potential environmental impacts attend and that overall, are common. They should be considered in the environmental management plan as a minimum requirement.
  • Item type:Ítem,
    Evaluación del ruido ambiente y su incidencia en las Otopías ocupacionales en la empres pública Empresa Municipal Mercado Mayorista Ambato.
    (Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Maestría en Producción más Limpia., 2015)
    Suárez Tapia, Ángel Jacobo
    ;
    Córdova Suárez, Manolo Alexander
    In the present investigation is related a study to the noise in the Empresa Pública -Empresa Municipal Mercado Mayorista Ambato- located in the city of Ambato, to determine the effects that produces noise on the health of their workers, and develop a program to prevent occupational otopathies. It was done by identifying physical risk factors, and the subsequent quantification of the physical risks and the the greater impact, by using the risk matrix INSHT, recommended by the Ministerio de Trabajo (Ministry of Labour). For further research, based on a study of the jobs positions, making measurements of noise and hearing tests, for workers who are directly exposed to this risk factor, checkpoints operators, control supervisors, and security guards. As a result of the research, a program of prevention for occupational otopathies is presented.