Ciencia e Ingeniería en Alimentos y Biotecnología
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/412
Examinar
2 resultados
Resultados de la búsqueda
Item type:Ítem, Evaluación del consumo de oxígeno por bacterias aeróbicas en aguas residuales de la planta de tratamiento de Ambato contaminadas con arsénico y cromo(Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Biotecnología, 2023-03) ;Freire Alegria, Sharon MayliPeñafiel Ayala, Rodny DavidIndustrial activities and population growth have led to an increase in the use of water resources and, therefore, the generation of wastewater. These have a high pollution load, both biological and non-biological (heavy metals, organic matter). For this reason, the objectives of this curricular integration project were to characterize the wastewater obtained from three secondary treatment points (the clarified effluent from the primary reactor, the mixed liquor from the biological reactor and the biosolids recirculation tank) of the Ambato wastewater treatment plant. Toxicity bioassays were also conducted by adding arsenic and hexavalent chromium, to verify how these metals affect the oxygen uptake rate and the inhibition of 20, 50 and 80 percent of microbial metabolism and growth. Determining that, as the concentration of the elements increased, the oxygen uptake rate decreased in both cases, as they decreased from 277 to 152 (arsenic) and from 288 to 68 milligrams of oxygen per liter per day (chromium). Furthermore, chromium was more toxic than arsenic, since the latter metal needed higher concentrations (1000 milligrams per liter) to achieve a 20 percent inhibition, as opposed to chromium, which needed only 13 milligrams per liter. Finally, these studies have been carried out with the purpose of providing alternatives to optimize wastewater treatment in future research.Item type:Ítem, Efecto de la adición de cadmio y de plomo sobre el consumo de oxígeno en la degradación de materia orgánica del agua residual cruda de la Planta de Tratamiento de Aguas Residuales de Ambato(Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Biotecnología, 2023-03) ;Aliaga Guerrero, Jean PierrePeñafiel Ayala, Rodny DavidThe residuals water treatment contributes to environmental sustainability by removing contaminants present in water. However, the biological treatment in a wastewater treatment plant (WWTP) be affected due to the high concentration of inorganic contaminants, such as heavy metals, causing deterioration of the system. The objective of the project was to evaluate the impact of the addition of cadmium and lead on the oxygen of aerobic bacteria that degrade the organic material, doing respirometric tests in relation to the increase in heavy metal concentrations. For the tests, the mixed liquor from the WWTP-Ambato biological reactor was collected and exposed to different concentration levels of cadmium and lead. The results revealed that in a concentration up to 2000 mg per L, both heavy metals had an inhibitory effect on oxygen consumption, with a maximum inhibition of 97.75 percent and 85.07 percent for Cd and Pb, respectively. Also, the cadmium and lead toxicity index were determined in the activity of the PTAR-Ambato biological reactor that causes a 20 percent inhibition (IC20) to be 23.32 mg Cd per L and 390.39 mg Pb per L, a 50 percent inhibition (IC50) to be 147.40 mg Cd per L y 671.08 mg Pb per L and 80 percent inhibition (IC80) to be 731.12 mg Cd per L y 951.38 mg Pb per L. In conclusion, the high levels of cadmium and lead toxicity suggest that aerobic bacteria are developing tolerance to these metals.
