Ciencia e Ingeniería en Alimentos y Biotecnología
URI permanente para esta comunidadhttp://repositorio.uta.edu.ec/handle/123456789/412
Examinar
2 resultados
Resultados de la búsqueda
Item type:Ítem, Determinación de vitamina B2 (Riboflamina) por Cromatografía líquida de alta eficacia (HPLC) en el Laboratorio ECUACHEMLAB Cía. Ltda.(Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Carrera de Ingeniería Bioquímica, 2016-09) ;Semanate Bautista, Mario FernandoCórdova Suárez, Manolo AlexanderThe validation of analytical methods is an essential process that laboratories must implement to ensure that the results of analyzes are reliable and reproducible with a basis and statistical analysis. Similarly, the methodology used for validation shows a great performance in working conditions of Ecuachemlab. For the determination of Vitamin B2 (Riboflavin) using high-performance liquid chromatography (HPLC), the methodology described in the AOAC 970.65 Method modified and ISO / IEC 17025 were used. They describe the guidelines and parameters for validation of the method used to ensure the validity results. The analytical parameters determined for method validation are linearity, working range, detection and quantification limits, precision, accuracy and uncertainty. The results, for linearity show a coefficient of correlation higher than r = 0.999 for each calibration curve, LD is equal to 0.002 ug / ml and the LC is 0.08 ug / ml. The working range comprises a concentration of 0.008 mg / ml of riboflavin as a lower limit and 1,003 ug / ml of riboflavin as an upper limit. The coefficient of variation for repeatability and reproducibility is less than 3 and 5% respectively. To determine the accuracy, a Z-score within the limits for each MRC was considered. Finally it was identified a combined and expanded uncertainty for the first three levels set of +/- 0.04 and +/- 0.08 mg vitamin B2 per 100 g of sample respectively. For the last level value it was established an uncertainty value of 0.05 +/- combined and expanded uncertainty equal to +/- 0.09 mg vitamin B2 per 100 g of sample, working at a confidence interval of 95% with a coverage factor k = 2.Item type:Ítem, Evaluación del desempeño del método de ensayo de sulfatos en matrices de aguas claras en el Laboratorio de Control y Análisis de Alimentos LACONAL de la Universidad Técnica de Ambato.(Universidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos. Carrera de Ingeniería Bioquímica, 2016-05) ;Cáceres Núñez, Johanna EstefaníaValencia Silva, Alex FabiánThe validation of analytical methods is part of a process of improving the quality of laboratories, which aims to demonstrate with substantiated evidence and statistical basis that both the method used and the result of this analysis is accurate and provides reliable data within a working range defined by careful control of conditions, materials and equipment, in order to adapt procedures to routine working environment. So this leads to a formal recognition of the competence of the laboratory, that is the accreditation. On the other hand, control of water quality is of increasing interest, because of the extended use and massive consumption of this resource. Based on these criteria, the analytical method for the determination of sulfates in drinking and bottled purified water matrices, based on the turbidimetric technique, was validated, using as reference the procedure established in 4500-SO42- E Standard Methods for the Examination of Water and Wastewater 22nd ed. The reliability of the method to produce the expected outcome was cheked, by assessing linearity, sensitivity, precision, accuracy and by the calculation of its uncertainty. The developed method produces a linear response within the range of 5 to 50 mg/L with r2 of 0,9961and m of 0,0041, however, as the TULAS expose a maximum allowable limit of 250 mg SO42-/L, a working interval of 4,9 (LOQ) to 250 mg SO42-/L was established by dilution, with a percentage expanded uncertainty of 9,3% (p= 95.45%) and coefficients of variation of %CVr= 5,83 and %CVR= 5,85%, respectively, percentages accepted according to the criteria established by the coefficient of variation of Horwitz (%CVh), and with an average recovery percentage of 100 ± 6% (MRC: 25 mg/L).
