Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Salazar Aguilar, Jairo David"

Filter results by typing the first few letters
Now showing 1 - 1 of 1
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Determinación de la eficiencia energética del sistema térmico de la casa de máquinas del Hospital General Ambato (IESS) usando la metodología propuesta por ISO 50001
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Mecánica, 2022-09) Salazar Aguilar, Jairo David; López Velástegui, Jorge Enrique
    For elaboration of this investigation, at first stage, components in machine room of the entity were identified. These elements are classified according to their sector: in generation, distribution and heat utilization equipment. Based on this, technical information about equipment installed in the place was collected. System losses were estimated according to the most recent period (December 2021 - March 2022), allowing to know anomalies that interfere in the operation of the environment in relation to numerical and quantifiable data. Similarly, financial costs were established about losses, reaching a value close to ten thousand dollars. The efficiency of the steam generator was evaluated at 84.67 percent (useful heat), distribution at 83.75 percent (harnessed heat) and heat exchanger at 42.43 percent. Improvement proposals were suggested that involve equipment cleaning based on maintenance periods, replacement of insulating materials and application of coating on specific surfaces, with the aim of raising the performance of the environment. Thus, the efficiency of the steam system would increase to 84.79 percent (harnessed heat) based on the recalculation with the suggested improvements. In addition, an annual saving of three thousand dollars was determined with a discount rate of 12 percent, with which the associated investment would be recovered in two years.

DSpace software copyright © 2002-2025 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify