dc.descriptionEl Proyecto de la Familia Pallo Sarabia cuenta con 6 plantas, incluyendo tapa gradas y subsuelo, con una altura total de 21.60m y está dividido en 3 bloques 1A, 1B y 1C, debido a que se encuentran separados por dos juntas de dilatación por ello, se realizó un análisis de vulnerabilidad sísmica con el propósito de determinar la factibilidad de cambio de uso de edificación de hotel a hospital. Por esta razón, se modeló la edificación con su uso actual y se realizó un análisis modal espectral, donde se determinó que los periodos de vibración, la acumulación de la masa modal y las derivas de piso no cumplen con lo establecido en la normativa NEC 2015, además de presentar un comportamiento torsional debido a los desplazamientos que producen los bloques de la edificación. Posteriormente se realizó un análisis estático no lineal, aplicando las metodologías que proporcionan el ATC-40 y FEMA 440, donde se comprobó que dos de los tres bloques analizados no alcanzaban el punto de desempeño frente a los diferentes niveles de amenaza sísmica, mientras que el bloque donde sí se obtuvo el punto de desempeño no tenía la capacidad esperada de acuerdo a los objetivos que establece la normativa VISUAL 2000, catalogando la estructura con un grado alto de vulnerabilidad sísmica. Finalmente, se demostró que la edificación con uso de hotel no es apta para realizar un cambio de edificación y se debería realizar un estudio de reforzamiento.es_ES
dc.description.abstractThe Pallo Sarabia Family Project has 6 floors, including the grandstand cover and basement, with a total height of 21.60m and is divided into 3 blocks 1A, 1B and 1C, since they are separated by two expansion joints. A seismic vulnerability analysis was carried out in order to determine the feasibility of changing the use of the building from a hotel to a hospital. For this reason, the building was modeled with its current use and a spectral modal analysis was carried out, where it was determined that the periods of vibration, the accumulation of the modal mass and the floor drifts do not comply with what is established in the NEC 2015 standard, in addition to presenting a torsional behavior due to the displacements produced by the building blocks. Subsequently, a non-linear static analysis was carried out, applying the methodologies provided by the ATC-40 and FEMA 440, where it was found that two of the three analyzed blocks did not reach the performance point against the different levels of seismic threat, while the The block where the performance point was obtained did not have the expected capacity according to the objectives established by the VISUAL 2000 regulations, cataloging the structure with a high degree of seismic vulnerability. Finally, it was shown that the building used as a hotel is not suitable for a change of building and a reinforcement study should be carried out.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectCAMBIO DE USOes_ES
dc.subjectHOTELes_ES
dc.subjectMODAL ESPECTRALes_ES
dc.subjectESTÁTICO NO LINEALes_ES
dc.subjectHOSPITALes_ES
dc.titleAnálisis de la factibilidad del cambio de uso de la edificación del proyecto de la familia Pallo Sarabia en la parroquia San Francisco, cantón Ambato, provincia de Tungurahuaes_ES
dc.typebachelorThesises_ES