dc.descriptionEl objetivo principal de esta investigación es determinar si la planta se encuentra funcionando de forma óptima. La evaluación de la PTAR de la comunidad empezó con un levantamiento de información y una investigación de campo para la toma de dimensiones, caudales de ingreso y así determinar el caudal de diseño a utilizar. También se realizó la toma de muestras de agua residual, mismas que fueron analizadas por un laboratorio acreditado y cuyos resultados fueron comparados con los parámetros límites que establece la normativa TULSMA 2015 para descargas de aguas residuales en cuerpos de agua dulce. Donde se comprobó que el parámetro aceites y grasas no cumple con dicha norma, lo cual indicó que la PTAR no está funcionando de forma adecuada. Finalmente se realizó un diagnóstico de cada uno de los procesos de tratamiento actual, en donde se encontró que algunas de sus estructuras como es el caso del tanque séptico no cumple con los criterios y recomendaciones que establecen los manuales de diseño. Por las razones antes nombradas se propone incorporar un nuevo proceso de tratamiento (trampa de grasas) para tratar el alto valor de dicho parámetro, realizar un rediseño de las estructuras que actualmente no cumplen con las normas, y finalmente incorporar un plan de operación y mantenimiento para asegurar el correcto funcionamiento de la PTAR a través del tiempo.es_ES
dc.description.abstractThe main objective of this research is to determine if the plant is operating optimally. The evaluation of the community WWTP began with the gathering of information, a field investigation which was used to take dimensions, inflow flows to determine the design flow to be used. Wastewater samples were also taken, which were analyzed by an accredited laboratory and whose results were compared with the limit parameters established by the TULSMA 2015 regulation for wastewater discharges into freshwater bodies, where it was found that the parameter oils and fats does not comply with the standards, which showed that the WWTP is not working properly. Finally, a diagnosis was made of each of the current treatment processes, where it was found that some of its structures, such as the septic tank, do not meet the criteria and recommendations established in the design manuals. For the reasons mentioned before, it is proposed to incorporate a new treatment process (fat trap) to treat the high value of that parameter. Also, to carry out a structure redesigns that now, currently do not comply with the standards, and finally to incorporate an operation and maintenance plan to ensure the correct operation of the WWTP through the time.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectPTARes_ES
dc.subjectTRAMPA DE GRASASes_ES
dc.subjectAGUAS RESIDUALESes_ES
dc.subjectTULSMA 2015es_ES
dc.subjectTANQUE SÉPTICOes_ES
dc.titleEvaluación de la planta de tratamiento de aguas residuales de la comunidad de Puñachizag, cantón Quero, provincia de Tungurahuaes_ES