Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/22990
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPeñafiel Luna Lic. Ft., Andrea Carolina-
dc.contributor.authorJaque Yancha, Diego Fernando-
dc.date.accessioned2016-05-16T16:36:31Z-
dc.date.available2016-05-16T16:36:31Z-
dc.date.issued2016-05-01-
dc.identifier.urihttp://repositorio.uta.edu.ec/jspui/handle/123456789/22990-
dc.descriptionSe probó la confiabilidad que tienen los test manuales prueba de lata vacía y prueba de arco doloroso medio en pacientes que presentan tendinitis del músculo supraespinoso, el lugar donde se realizó la investigación fue el hospital del Instituto Ecuatoriano de Seguridad social (I.E.S.S) de la ciudad de Ambato la población que se utilizo fue de 30 participantes en los cuales se aplicó cada uno de los diferentes test manuales, la presente investigación es de tipo descriptivo con un enfoque cuali-cuantitativo. Los resultados que se obtuvieron en la investigación demostró que el test manual prueba de lata vacía tiene un porcentaje de confiabilidad del 90% y la prueba de arco doloroso medio tiene un porcentaje de confiabilidad del 60% al momento de valorar el músculo supraespinoso. Una vez que se obtuvo los datos se procedió a tabular. Los test manuales proporcionaron la información que se necesita para cumplir con los objetivos de la investigación para determinar la confiabilidad que tienen al momento de utilizarlos en una valoración física en la obtención del diagnóstico del musculo supraespinoso. El análisis estadístico que se utilizo fue coeficiente de correlación que demostró la relación de 0,40824829 que tiene cada uno de los test manuales al momento de valorar el músculo supraespinoso.es_ES
dc.description.abstractReliability with manual test test empty can and testing means painful arc in patients with tendinitis of the supraspinatus muscle was tested, where the research was conducted was the hospital of the Ecuadorian Institute of Social Security (IESS) City Ambato people I was used was 30 participants which was applied each of the different manual test, this research is descriptive with qualitative and quantitative approach. The results obtained in the investigation showed that the test manual empty can test has a reliability rate of 90% and painful arc test medium has a reliability rate of 60% when assessing the supraspinatus muscle. Once the data is obtained tabular proceeded to. The manual test provided the information needed to meet the objectives of the investigation to determine the reliability they have the time to use them in a physical assessment in obtaining the diagnosis of supraspinatus muscle. The statistical analysis used was correlation coefficient showed the ratio of 0.40824829 that each one of the manuals when assessing the supraspinatus muscle test.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato-Facultad de Ciencias de la Salud-Carrera Terapia Físicaes_ES
dc.rightsopenAccesses_ES
dc.subjectCONFIABILIDADes_ES
dc.subjectTENDINITISes_ES
dc.subjectLATA VACIAes_ES
dc.subjectARCO DOLOROSO MEDIOes_ES
dc.subjectPRUEBAes_ES
dc.titleConfiabilidad de los Test Manuales, Prueba de Lata Vacía y Prueba del Arco Doloroso Medio en el Diagnóstico de Tendinitis del Supraespinosoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Terapia Física

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Derechos de Autor.pdf102,03 kBAdobe PDFVisualizar/Abrir
Diego Jaque.pdf805,91 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.