Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/34959
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPérez Aldas, Lander Vinicio-
dc.contributor.authorAguirre Tubón, Ana Belén-
dc.date.accessioned2022-04-03T20:33:58Z-
dc.date.available2022-04-03T20:33:58Z-
dc.date.issued2022-03-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/34959-
dc.descriptionLa validación del método para determinación de tensoactivos en muestras de agua por espectrofotometría UV-vis se llevó a cabo en el laboratorio de análisis y evaluación ambiental AqLab en la ciudad del Coca. Su validación se realizó tomando en cuenta la necesidad analítica del laboratorio, parámetros de validación de la norma INEN ISO IEC 17025 y normativas del SAE, normativas ambientales descritas en el TULSMA, en su Norma de Calidad Ambiental y de descarga de efluentes: Recurso Agua y Ordenanzas municipales del cantón Orellana. Se utilizó el método 5540 C correspondiente a la determinación de tensoactivos aniónicos como MBAS descrito en los Métodos Estándar para las matrices de agua de consumo humano, agua natural y agua residual. Se estableció los objetivos de validación y se planteó el diseño experimental correspondiente en condiciones de repetibilidad y reproducibilidad. Se analizó los siguientes parámetros: Función Respuesta, Límite de detección, Límite de cuantificación, Precisión (Repetibilidad y reproducibilidad), Veracidad, Incertidumbre e Intervalo de trabajo del método. Mediante el análisis estadístico de datos se demostró que el método es adecuando para la aplicación prevista, al cumplir con los objetivos de validación planteados correspondientes a un CVr y CVR menor al 30 por ciento para precisión, un porcentaje de recuperación de 80 al 120 por ciento para veracidad, una incertidumbre U menor al 30 por ciento con un intervalo de confianza del 95 por ciento (k es 2) y un intervalo de trabajo del método que comprende los niveles de concentración de 0,1 a 8,85 ppm de MBAS.es_ES
dc.description.abstractThe validation of the method for determination of surfactants in water samples by UV-vis spectrophotometry was carried out in the environmental analysis and evaluation laboratory Aqlab in the city of Coca. Its validation was carried out taking into account the analytical need of the laboratory, validation parameters of the INEN ISO IEC 17025 standard and SAE regulations, environmental regulations described in the TULSMA, in its Environmental Quality and Effluent Discharge Standard: Water Resource and the Municipal Ordinances of the Orellana Canton. The method 5540 C corresponding to the determination of anionic surfactants as MBAS described in the Standard Methods was used for the matrices of water for human consumption, natural water and waste water. The validation objectives were established and the corresponding experimental design was proposed under conditions of repeatability and reproducibility. The following parameters were analyzed: Response Function, Limit of detection, Limit of quantification, Precision (repeatability and reproducibility), Veracity, Uncertainty and Working Interval of the method. Through the statistical analysis of data, it was demonstrated that the method is suitable for the intended application, by meeting the validation objectives set for a CVr and CVR less than 30 percent for accuracy, a recovery percentage of 80 to 120 percent for veracity, an uncertainty U less than 30 percent with a 95 percent confidence interval (k is 2) and a method working range comprising concentration levels 0,10 to 8,85 ppm MBAS.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología. Carrera de Ingeniería Bioquímicaes_ES
dc.rightsopenAccesses_ES
dc.subjectQUÍMICA ANALÍTICAes_ES
dc.subjectMÉTODOS ANALÍTICOSes_ES
dc.subjectESPECTROFOTOMETRÍA UV-VISes_ES
dc.subjectGESTIÓN DE CALIDADes_ES
dc.subjectCALIDAD DEL AGUAes_ES
dc.subjectTENSOACTIVOSes_ES
dc.subjectAQLABes_ES
dc.titleValidación del método para determinación de detergentes en muestras de agua por espectrofotometría UV-Vis en el laboratorio AqLab de la ciudad del Cocaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Carrera Ingeniería Bioquímica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
BQ 300.pdfTrabajo a texto completo7,83 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.