Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/33243
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorNavarro Peñaherrera, Carlos Patricio-
dc.contributor.authorGallardo Sinchiguano, Romel Amilcar-
dc.date.accessioned2021-08-28T03:00:42Z-
dc.date.available2021-08-28T03:00:42Z-
dc.date.issued2021-08-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/33243-
dc.descriptionEn el país la norma vigente (NEC-2015) establece un formulario de inspección visual rápida para un análisis cualitativo de estructuras basado del propuesto por FEMA 154, cuyo objetivo fundamental es determinar la vulnerabilidad sísmica que presentan las construcciones. En el presente proyecto se obtuvo una diferencia en cuanto al análisis por las dos metodologías, por FEMA 154 la estructura presenta alta vulnerabilidad sísmica mientras que por la NEC-2015 presenta una vulnerabilidad sísmica media correspondiente a la irregularidad en elevación y la presencia de columnas cortas. En el análisis lineal tanto estático como dinámico y análisis estático inelástico, dentro de los primeros análisis se determinó el periodo fundamental de vibración que demuestra flexibilidad en la estructura y se debe rigidizar, a su vez se comprobó con las derivas inelásticas puesto que sobrepasan el límite permisible del 2 por ciento; en cuanto al análisis estático inelástico se determinó que la edificación no tiene la capacidad necesaria demostrando que colapsa ante la presencia de un sismo. Por lo que se propuso un reforzamiento a nivel global y local, el primero por medio de cruces de San Andrés y el segundo en las columnas que presentan un efecto de columna corta debido al cambio de nivel que se observó en el edificio a través de un encamisado metálico por ángulos y soleras. Finalmente, se determinó la frecuencia natural de los entrepisos del edificio a través de sus deflexiones para verificar que las vibraciones se encuentren en límite permisible establecido en la guía 11 del AISC.es_ES
dc.description.abstractIn the country, the current standard (NEC-2015) establishes a rapid visual inspection form for a qualitative analysis of structures based on the one proposed by FEMA 154, whose main objective is to determine the seismic vulnerability of buildings. In this project, a difference was obtained in terms of the analysis by the two methodologies, by FEMA 154 the structure presents high seismic vulnerability while by NEC-2015 it presents an average seismic vulnerability corresponding to the irregularity in elevation and the presence of short columns. . In both static and dynamic linear analysis and inelastic static analysis, within the first analyzes the fundamental period of vibration was determined that shows flexibility in the structure and must be stiffened, in turn it was verified with inelastic drifts since they exceed the limit allowable 2 percent; Regarding the inelastic static analysis, it was determined that the building does not have the necessary capacity, showing that it collapses in the presence of an earthquake. Therefore, a reinforcement was proposed at a global and local level, the first through San Andrés crosses and the second in the columns that present a short column effect due to the change in level that was observed in the building through a metallic cladding for corners and sills. Finally, the natural frequency of the building's mezzanines was determined through their deflections to verify that the vibrations are within the permissible limit established in guide 11 of the AISC.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectANÁLISIS ESTRUCTURALes_ES
dc.subjectDESEMPEÑO SÍSMICOes_ES
dc.subjectVULNERABILIDAD ESTRUCTURALes_ES
dc.subjectVULNERABILIDAD SÍSMICAes_ES
dc.subjectREFORZAMIENTO ESTRUCTURALes_ES
dc.titleAnálisis estructural del desempeño sísmico del edificio de la Facultad de Ingeniería en Sistemas, Electrónica e Industrial bloque 2 mediante la medición de vibracioneses_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I. C. 1493 - Gallardo Sinchiguano Romel Amilcar.pdfTESIS A TEXTO COMPLETO21,87 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.