Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/30593
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorUreña Aguirre, Maritza Elizabeth-
dc.contributor.authorChafla Ríos, Monserrath Carolina-
dc.date.accessioned2020-01-20T15:43:23Z-
dc.date.available2020-01-20T15:43:23Z-
dc.date.issued2020-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/30593-
dc.descriptionPara la ejecución del presente trabajo experimental, en primer lugar, se recolectó los agregados necesarios para la fabricación de los bloques propuestos: chasqui de minas ubicadas en Laso, polvo proveniente de Pujilí y cascarilla de coco que se adquirió en el sector Cotocollao (Quito). A continuación, se efectuaron los ensayos granulométricos, de absorción y densidades de todos los materiales bajo las normas INEN en el Laboratorio de Mecánica de Suelos y Ensayo de Materiales de la Facultad de Ingeniería Civil y Mecánica de la Universidad Técnica de Ambato. Con los resultados obtenidos, se procedió a la dosificación de los bloques por el método de densidad óptima tanto para bloques huecos tradicionales como para bloques huecos con sustitución parcial del 10por ciento, 20 por ciento y 30 por ciento con cascarilla de coco. Los ensayos de resistencia a compresión se realizaron a los 7, 14 y 28 días, mientras que los ensayos de resistencia a impacto y resistencia a fuego se realizaron a los 14 y 28 días. La resistencia a compresión a los 28 días de los bloques tradicionales fue de 3,77 MPa, mientras que la de los bloques con 30% de sustitución por cascarilla de coco fue de 5,67 MPa. En cuanto a la resistencia a impacto se pudo apreciar durante el ensayo que disminuye el número de desprendimientos del material mientras más sustitución de cascarilla de coco se adiciona. Por último, en la resistencia a fuego los bloques sometidos a altas temperaturas sufrieron cambios de apariencia y disminución de resistencia, sin embargo, luego de ser sometidos a compresión, los bloques al 30por ciento de sustitución aún conservan sus propiedades de resistencia (4,35 MPa), dentro del límite según la norma NTE INEN 3066, a diferencia de los bloques normales que tuvieron 2,61 MPa. Finalmente, se deduce que mientras más se sustituye en porcentajes la cascarilla de coco, el bloque disminuye en peso y a la vez aumenta en resistencia. Determinándose que el porcentaje óptimo de sustitución de cascarilla de coco es del 30 por cientoes_ES
dc.description.abstractFor the execution of this experimental work, in the first place, the aggregates necessary for the manufacture of the proposed blocks were collected of: chasqui mines located in Laso, powder from Pujilí and coconut shell that was acquired in the Cotocollao sector (Quito). Next, the granulometric, absorption and density tests of all materials were performed under the INEN standards in the Soil Mechanics and Materials Testing Laboratory of the Faculty of Civil and Mechanical Engineering of the Technical University of Ambato. With the achieved results, the dosage of the blocks by the optimal density method were developed for both: traditional hollow blocks and hollow blocks with partial replacement of 10%, 20% and 30% with coconut shell. Compressive strength tests were performed at 7, 14 and 28 days, while impact resistance and fire resistance tests were performed at 14 and 28 days. Compressive strength at 28 days of the traditional blocks was 3,77 MPa, while that of the blocks with 30% substitution by coconut shell was 5,67 MPa. With respect to impact resistance, it was observed during the test that the number of detachments of the material decreases while more coconut shell replacement is added. Finally, in fire resistance, the blocks subjected to high temperatures suffered changes in appearance and decreased resistance, however, after being subjected to compression, the 30% replacement blocks still retain their resistance properties (4,35 MPa), within the limit according to NTE INEN 3066, unlike normal blocks that had 2,61 MPa. Finally, from this it follows that while more coconut shell is replaced in percentages, the block decreases in weight and at the same time increases in resistance. Determining that the optimal percentage of coconut shell replacement is 30%.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectRESISTENCIA A COMPRESIÓNes_ES
dc.subjectFUEGO DE BLOQUESes_ES
dc.subjectIMPACTO DE BLOQUESes_ES
dc.subjectHUECOS DE HORMIGÓNes_ES
dc.subjectCASCARILLA DE COCOes_ES
dc.subjectBLOQUES DE CEMENTOes_ES
dc.subjectFABRICACIÓN DE BLOQUESes_ES
dc.titleEstudio comparativo de la resistencia a compresión, fuego e impacto de bloques huecos de hormigón tradicional y bloques elaborados con sustitución parcial del agregado grueso por cascarilla de cocoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I. C. 1370 - Chafla Rios Monserrath Carolina.pdfTESIS A TEXTO COMPLETO4,49 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.