Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/29942
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMedina Robalino, Christian David-
dc.contributor.authorGalarza Altamirano, Daniela Alexandra-
dc.date.accessioned2019-07-22T20:37:51Z-
dc.date.available2019-07-22T20:37:51Z-
dc.date.issued2019-
dc.identifier.urihttp://repositorio.uta.edu.ec/jspui/handle/123456789/29942-
dc.descriptionPara la investigación en primera instancia se consiguió los planos estructurales del edificio ―Oscus‖, además se obtuvo la resistencia a compresión de concreto mediante ensayos esclerómetrico, la normativa vigente en el año de construcción fue el Código Ecuatoriano de la Construcción (CEC-77 en base al ACI 318-71). A partir de esta información se modelo el edificio en tres dimensiones en el software Etabs 2016, tomando en cuenta parámetros de no linealidad. Para la definición de la demanda se utilizó el espectro de respuesta y acelerogramas propiamente seleccionados, ajustados y escalados de acuerdo a la NEC-SE-DS para un sismo con probabilidad de excedencia de 50 años del 10% . Se recopiló información necesaria a partir de publicaciones tales como: FEMA-440, FEMA-356 y ATC- 40 además de artículos científicos. Se realizó procedimientos de análisis sísmicos no lineales como: Historia de Respuesta (NL-RHA), Pushover (NSP) y Pushover Multimodal (MPA), mediante la definición de sus respectivos casos modales, una vez finalizado el análisis se procedió al procesamiento de resultados, los cuales fueron comparados en términos de desplazamientos, derivas, capacidad y nivel de daño, en donde se pudo detectar algunas deficiencias, limitaciones, ventajas y desventajas de los análisis. De las metodologías alternativas de análisis sísmico estudiadas, la que produce los errores más pequeños es el análisis MPA, por tal razón, se concluye que es la más adecuada. Los tres análisis determinaron que la estructura llega a su desplazamiento máximo antes de cumplir con su desplazamiento objetivo lo que significa una gran inconsistencia en su desempeño sísmico demostrando su alta vulnerabilidad y riesgo de posible colapso.es_ES
dc.description.abstractFor this investigation, in first instance the structural plans of the building "Oscus" were obtained, in addition the resistance to compression of concrete was obtained by means of sclerometric tests, the current regulations in the year of construction was the Ecuadorian Code of Construction (CEC-77 in base of ACI 318-71). Based on this information, the building was modeled in three dimensions in Etabs 2016 software, considering non-linearity parameters. For the definition of the demand, the response spectrum and appropriately selected accelerograms were used, adjusted and scaled according to the NEC-SE-DS for an earthquake with probability of exceeding 50 years of 10% . Necessary information was gathered from publications such as: FEMA-440, FEMA- 356 and ATC-40 in addition to scientific articles. Non-linear seismic analysis procedures were performed, such as: Time History (NL-RHA), Pushover (NSP) and Multimodal Pushover (MPA), by defining their respective modal cases, once the analysis was finished, the results were processed. , which were compared in terms of displacements, drifts, capacity and level of damage, where it was possible to detect some deficiencies, limitations, advantages and disadvantages of the analyzes. Of the alternative seismic analysis methodologies studied, the one that produces the smallest errors is the MPA analysis, for this reason, it is concluded that it is the most appropriate. The three analyzes determined that the structure reaches its maximum displacement before fulfilling its objective displacement which means a great inconsistency in its seismic performance demonstrating its high vulnerability and risk of possible collapse.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectDESEMPEÑO SÍSMICOes_ES
dc.subjectANÁLISIS ESTÁTICO NO LINEALes_ES
dc.subjectPUSHOVERes_ES
dc.subjectANÁLISIS ESTÁTICO MODALes_ES
dc.subjectPUSHOVER MULTIMODALes_ES
dc.subjectDINÁMICO NO-LINEALes_ES
dc.subjectHISTORIA DE RESPUESTAes_ES
dc.subjectDESPLAZAMIENTOS DE PISOes_ES
dc.subjectRANGO ELÁSTICOes_ES
dc.subjectCOMBINACION MODALes_ES
dc.subjectNIVEL DE DAÑOes_ES
dc.subjectDERIVAS DE PISOes_ES
dc.subjectCORTANTE BASALes_ES
dc.titleEvaluación del desempeño sísmico del edificio de la Oscus mediante comparación del análisis estático no lineal (Pushover), análisis estático modal (Pushover Multimodal) y dinámico no-lineal (Historia de Respuesta).es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I. C. 1334 - Galarza Altamirano Daniela Alexandra.pdfTESIS A TEXTO COMPLETO6,8 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.