dc.descriptionEl presente trabajo de investigación se realizó prototipos con diferentes conectores de cortante, seleccionados por las propiedades de cada elemento, la capacidad de absorción y transferencia de esfuerzos cortantes de la losa a la viga y además del uso frecuente en obra. Los conectores de cortante que fueron parte de esta investigación eran de tipo (arco de varilla corrugada Ø8mm, tornillo, espigo y tipo estribo) todos estos dispositivos cumplen con funciones que fueron reflejados en los ensayos como: impedir el deslizamiento horizontal y separación vertical entre losa compuesta y la viga de hormigón, pérdida de adherencia entre el hormigón y la placa colaborante y obtener la resistencia máxima a la flexión mayor que si cada elementos funcionara por sí solo. Para identificar a un elemento estructural como compuesto este debe garantizar la interacción entre el material de acero y de hormigón mediante el cual se llegó a los resultados con el uso de los conectores de cortante. El desempeño de los elementos compuestos es decir de los prototipos se dio por el número y espaciamiento de los conectores de cortante que aumento la resistencia a la flexión y fueron esenciales para el comportamiento ante las solicitaciones requeridas.es_ES
dc.description.abstractThe present research work was carried out prototypes with different shear connectors, selected by the properties of each element, the capacity of absorption and transfer of shear stresses of the slab to the beam and besides the frequent use in work. The shear connectors that were part of this research were of type (corrugated rod Ø8mm, screw, spigot and stirrup type) all these devices fulfill functions that were reflected in the tests as: to prevent the horizontal sliding and vertical separation between slab Composite and the concrete beam, loss of adhesion between the concrete and the cooperating plate and obtain the maximum resistance to flexion greater than if each elements worked alone. To identify a structural element as a composite, it must ensure the interaction between the steel and concrete material by which the results were achieved with the use of the shear connectors. The performance of the composite elements ie prototypes was given by the number and spacing of the shear connectors which increased the flexural strength and were essential for the behavior to the required stresses.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectHORMIGONESes_ES
dc.subjectVIGASes_ES
dc.subjectLOSASes_ES
dc.subjectPROPIEDADES MECÁNICASes_ES
dc.subjectENSAYOS DE LABORATORIOes_ES
dc.titleAnálisis de la influencia de los conectores de cortante en la unión viga de hormigón y losa compuestaes_ES
dc.typebachelorThesises_ES